ABB - Installation Products R2IT15M1-H0240 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

ABB Installation Products R2IT15M1-H0240 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114155984


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2IT15M1-H0240) is a Type Indoor termination engineered for 15kV cable systems in utility, industrial, and commercial power distribution. This termination supports tape shield, wire shield, or unshielded cables with insulation diameters from 0.64 inch to 1.12 inch, accommodating stranded or compressed conductors from 1/0 AWG to 2/0 AWG, including 240-strand configurations. The aluminum 1-hole spade connector is rated for #2-500 kcmil, ensuring secure, high-current connections in medium-voltage applications. Designed for indoor installations, the Ranger2 termination leverages shrink-fit technology to cover the widest range of cable sizes with minimal model variation. Three sizes handle cables from #2 AWG to 1250 kcmil, including popular XLP and EPR cable types. The non-tracking silicone housing delivers superior memory and weathering resistance, while the field-removable center core simplifies installation and maintenance. Optional insulating silicone sleeves provide additional creepage distance and wildlife protection when required. Key applications include substation terminations, switchgear connections, and indoor cable terminations in medium-voltage switchboards. The compact footprint and standardized connector interface reduce installation time and downtime during upgrades or repairs. With a maximum design voltage to ground of 9.5 kV, lightning impulse withstand of 110 kV crest, and a 50 kV 1-minute dry withstand rating, the Ranger2 termination meets IEEE 48 standards for reliable long-term service in controlled indoor environments. Ambient operating temperatures range from -22°F to +149°F (-30°C to +65°C), with altitude limits up to 3,300 feet (1,005 meters).
  • Supports 15kV indoor cable systems with insulation diameters from 0.64" to 1.12"
  • Accommodates stranded or compressed conductors from 1/0 AWG to 2/0 AWG (240-strand)
  • Aluminum 1-hole spade connector rated for #2-500 kcmil
  • Non-tracking silicone housing with superior weathering and memory characteristics
  • Field-removable center core for simplified installation and maintenance

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10240-4

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.

R2IT15J1-N0260

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-1250 kcmil, Conductor Code - 260 -Stranded or Compressed 3/0 Compact or Solid 4/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2IT15J1-H0250

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T35M4-N2310-B4

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15J1-H0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

R2IT15J2-N2310-B2

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T15J4-N0350

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 400 / Compact or Solid 500 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T35J4-N2310-B4

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 400 / Compact or Solid 500 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

Frequently Asked Questions

What is the DC Withstand voltage for this termination?

The DC Withstand voltage for 15 minutes dry is 75 kV.

What is the voltage rating of this termination?

The R2IT15 cable termination has a voltage rating of 15 kV.

What cable sizes are compatible with this termination?

This termination accommodates cable sizes from #2 AWG through 1250 kcmil, covering insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What is the operating temperature range for this product?

The ambient temperature range for this termination is -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for installation?

The maximum altitude range for installation is 3300 feet (1005 m).

What is the power system frequency range?

The power system frequency range for this termination is 48 to 62 Hz.

What is the IEEE classification for this indoor termination?

The IEEE classification for this indoor termination is Class 2.

What is the minimum strike distance of the termination?

The minimum strike distance of the termination is 8.4 inches (213 mm).

What is the creepage distance of the termination?

The creepage distance of the termination is 8.4 inches (213 mm).

What is the Lightning Impulse Withstand Voltage (BIL)?

The Lightning Impulse Withstand Voltage (BIL Dry 110 Withstand) is 110 kV Crest.

How to Install the 15kV Ranger 2 Shrink Fit Silicone Rubber Termination (R2IT15M)

This guide provides step-by-step instructions for the indoor installation of the 15kV Ranger 2 Shrink Fit Silicone Rubber Termination (R2IT15M) on tape-shielded cables. It is crucial to de-energize all apparatus and adhere to high-voltage safety practices. Note that this indoor kit does not provide a moisture-resistant seal; use indoor/outdoor kits if moisture resistance is required.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Cable stripping tools, Crimping tool, Measuring tape or ruler, Marker, Cleaning pads, Aluminum oxide abrasive (grit 120 or finer, optional)

Supplies needed:

R2IT15M 15kV Ranger 2 Shrink Fit Silicone Rubber Termination Kit (includes: Silicone Rubber Termination, Preformed Ground Braid, Constant Force Spring, Lubricant, Copper Foil Tape, Gloves), Vinyl electrical tape, Compatible terminal lug or connector, Cable cleaning solvent

  1. Prepare the Cable

    Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into its final position and cut it to the required length for installation. Prepare the cable according to the provided dimensions, ensuring to account for the depth of the terminal lug and any growth allowance for aluminum lugs. Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install the Ground Braid

    Wrap one band of vinyl tape around the cable jacket 1/4 inch (6mm) from the jacket end; this serves as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape marker. Secure the ground braid to the cable jacket using vinyl tape. Apply a second vinyl tape band directly over the original marker and ground braid solder block, carefully maintaining the 1/4 inch (6mm) dimension. Wrap the ground braid around the cable tape shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring, wrapping the spring in the same direction as the ground braid. Cinch (tighten) the spring after the final winding. Secure the spring with two wraps of vinyl tape. For cables with cloth or paper semi-conductive shields, overwrap the shield with one half-lapped layer of highly stretched semi-conductive rubber tape.

  3. Install the Terminal Lug or Connector

    Check that the termination assembly can fit over the selected lug. If the lug will not fit through the termination core, clean the cable insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer’s instructions. Do not crimp the last 3/8 inch to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings or edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with solvent-saturated pads, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use it only on the insulation, not on the semi-conductive insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below the kit's allowed specifications.

  5. Install the Termination Body

    Apply a liberal coating of silicone grease (lubricant) to the edge of the semi-conductive insulation shield to fill the step at the semi-con cut-off. Slide the termination body onto the cable, aligning its edge with the forward edge of the vinyl tape marker. Carefully begin to remove the core by pulling counter-clockwise. Recheck the termination position and continue to remove the core. Do not push or pull on the termination assembly while removing the core. Finally, connect the ground braid to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.