ABB - Installation Products R2IT15J1-H0240 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

ABB Installation Products R2IT15J1-H0240 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114200448


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2IT15J1-H0240, is designed for indoor applications requiring reliable 15kV cable termination. This unit is specifically engineered for Concentric Neutral and Jacketed Concentric Neutral cable types. Its insulation range accommodates cables with diameters from 0.64 inches to 1.12 inches, providing a secure fit for a variety of conductor sizes. The termination features a robust aluminum 1-hole spade connector, compatible with conductor sizes ranging from #2 AWG to 500 kcmil. For conductor code 240, it supports stranded or compressed 1/0 AWG compact conductors, as well as solid 2/0 AWG conductors. This product ensures a secure and electrically sound connection for medium-voltage power distribution systems within indoor facilities. ABB's Installation Products division delivers dependable solutions for electrical infrastructure. UNSPSC: 26121648.
  • Indoor 15kV cable termination
  • For Concentric Neutral/Jacketed Concentric Neutral cable types
  • Insulation range: 0.64 inch - 1.12 inch
  • Aluminum 1-hole spade connector (#2-500 kcmil)
  • Supports conductor code 240 (1/0 AWG compact, 2/0 AWG solid)

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10240-3

15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.

R2IT15J2-N2310-B2

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T15J4-N0350

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 400 / Compact or Solid 500 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T35J4-N2310-B4

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 400 / Compact or Solid 500 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T15J2-N0330-B3

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .

R2T35M4N2330

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1/0/ Compact or Solid 2/0 .

R2T35M2N2240

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1/0/ Compact or Solid 2/0 .
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 3/0/ Compact or Solid 4/0 .

R2T35M2N2260

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 3/0/ Compact or Solid 4/0 .

Frequently Asked Questions

What is the DC Withstand voltage for R2IT15?

The DC Withstand for the R2IT15 is 75 kV for 15 minutes dry.

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with R2IT15 terminations?

R2IT15 terminations accommodate cables from #2 AWG through 1250 kcmil, covering insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the operating temperature range for R2IT15?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 installation?

The R2IT15 termination can be installed at an altitude range of up to 3300 feet max (1005 m).

What is the power system frequency range for R2IT15?

The R2IT15 termination is designed for a power system frequency range of 48 to 62 Hz.

What is the IEEE classification for R2IT15 indoor use?

The R2IT15 indoor termination has an IEEE Classification of Class 2.

What installation instructions are available for R2IT15?

Installation instructions are IS-1134 for R2IT15J, IS-1135 for R2IT15M, and IS-1136 for R2IT15L.

What is the minimum strike and creepage distance?

The R2IT15 has a minimum strike distance of 8.4 in (213 mm) and a creepage distance of 8.4 in (213 mm).

What is the Lightning Impulse Withstand Voltage?

The Lightning Impulse (BIL Dry 110 Withstand) for the R2IT15 is 110 kV Crest.

How to Install the 15kV Ranger 2 Cable Terminator (R2IT15J)

This guide provides step-by-step instructions for installing the 15kV Ranger 2 Cable Terminator for indoor applications on concentric and jacketed concentric neutral cables. Ensure all safety precautions are followed.

Estimated time: 45m

Tools needed:

Approved solvent, Aluminum oxide abrasive (grit 120 or finer, optional), Crimping tool, Wire strippers, Cable preparation tools

Supplies needed:

Silicone Rubber Termination, Lubricant, Gloves, Terminal lug, Silicone grease, Vinyl tape (if needed for neutral wires), Connector (optional), Cable Support Bracket (optional)

  1. De-energize and Prepare for Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow instructions will result in serious injury. Inspect all parts for damage, rating, and compatibility. Check kit contents and ensure proper fit with cable and mating products. Read all instructions before starting.

  2. Prepare the Cable

    Verify the cable size fits within the kit range using the Termination Selection Chart. Train the cable into position and cut to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions, allowing for terminal lug depth and additional exposed conductor distance for aluminum lugs (e.g., 1/4” for #2-350, 1/2” for 400-650, 3/4” for 750-1000). For concentric neutral cable, bend neutral wires back and secure them as instructed.

  3. Install the Lug or Connector

    If using non-Elastimold lugs that will not fit through the termination core, clean the cable insulation and slide the termination onto the cable before installing the lug. Do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer’s directions, leaving the last 1/4” to 3/8” of the connector uncrimped. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not the semi-con shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.

  5. Install the Termination Body

    Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. Slide the terminator body onto the cable, aligning the terminator skirt with the edge of the cable jacket. Carefully begin to remove the core by rotating the lead counter-clockwise as you pull. Recheck the terminator position and continue removing the core. Do not push or pull on the terminator assembly while removing the core.

  6. Ground Neutral Wires

    Twist the concentric neutral wires together and securely connect them to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.