Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2IT15J2-N2310-B2 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500. Cable Mounting Bracket - B2 - Stainless Steel - Size 1.10 inch - 1.50 inch.
More images

ABB Installation Products R2IT15J2-N2310-B2 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 075114205603


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2IT15J2-N2310-B2, is a high-performance indoor termination system designed for 15kV applications. This termination system is specifically engineered for use with Concentric Neutral and Jacketed Concentric Neutral cable types, ensuring reliable performance in medium-voltage electrical installations. It accommodates insulation diameters ranging from 0.84 inches to 1.38 inches, providing compatibility with a defined range of cable sizes commonly used in industrial and utility applications. The included connector is a copper 2-hole spade, rated for conductors ranging from #2 AWG to 1250 kcmil, offering versatility for various conductor sizes. Specifically, it supports stranded or compressed 400 kcmil conductors, solid 500 kcmil conductors, and 400 kcmil compact conductors, as indicated by Conductor Code 310. The integrated cable mounting bracket, designated as B2, is constructed from durable stainless steel and is sized for cables with diameters between 1.10 inches and 1.50 inches, ensuring secure and stable mounting in demanding environments. This termination system is part of ABB's Installation Products catalog, which provides reliable and efficient termination solutions for electrical infrastructure, including power distribution, industrial facilities, and renewable energy projects. UNSPSC Code: 26121648.
  • Indoor 15kV termination for Concentric Neutral/Jacketed Concentric Neutral cables
  • Insulation Range: 0.84 inch - 1.38 inch
  • Connector: Copper 2-Hole Spade (#2 - 1250 kcmil)
  • Conductor Support: Stranded/Compressed 400 kcmil, Solid 500 kcmil (Code 310)
  • Stainless Steel Cable Mounting Bracket (B2): 1.10 inch - 1.50 inch size

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
400 to 500 kcmil
Connection Type
2-Hole Spade
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Bracket
Number Of Terminals
(1) Single Phase
Size
0.84 inch - 1.38 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.4700 L
Package Weight (Metric)
0.6670 kg
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

R2T28M2-N2310

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T15J4-N0350

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 400 / Compact or Solid 500 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).

R2T35J4-N2310-B4

Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neutral/Jacketed Concentric Neutral Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 400 / Compact or Solid 500 . - Cable Mounting Bracket - Stainless Steel, 1.80 inch - 2.40 inch (45-61mm).
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

R2T15J2-N0330-B3

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .

R2T35M4N2330

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 500/ Compact or Solid 600 .
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1/0/ Compact or Solid 2/0 .

R2T35M2N2240

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 1/0/ Compact or Solid 2/0 .
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 3/0/ Compact or Solid 4/0 .

R2T35M2N2260

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 3/0/ Compact or Solid 4/0 .
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 4/0, / Compact or Solid 250.

R2IT15J1-H0270

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 1-Hole Spade #2-500kcmil, Stranded or Compressed 4/0, / Compact or Solid 250.

Frequently Asked Questions

What is the operating temperature range for this termination?

The R2IT15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable sizes are compatible with the R2IT15 termination?

The R2IT15 termination accommodates cable sizes from #2 AWG through 1250 kcmil, covering insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV.

What is the maximum altitude for R2IT15 termination installation?

The R2IT15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the Lightning Impulse Withstand Voltage (BIL Dry)?

The Lightning Impulse (BIL Dry 110 Withstand) voltage for the R2IT15 is 110 kV Crest.

What is the Coronal Extinction Voltage for the R2IT15?

The Coronal Extinction Voltage (Partial Discharge) for the R2IT15 termination is 13 kV (≤ 3pC).

What is the minimum strike distance for the R2IT15 termination?

The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).

What is the IEEE classification for the R2IT15 indoor termination?

The R2IT15 indoor termination has an IEEE Classification of Indoor = Class 2.

What is the power system frequency range for the R2IT15?

The R2IT15 termination is designed for a power system frequency range of 48 to 62 Hz.

What is the minimum strike distance for the R2IT15 termination?

The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).

How to Install the 15kV Ranger 2 Cable Terminator (Indoor)

This guide provides step-by-step instructions for the safe and proper installation of the 15kV Ranger 2 Cable Terminator for indoor applications on concentric and jacketed concentric neutral cables. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (120 grit or finer, optional)

Supplies needed:

Silicone Rubber Termination kit, Silicone grease, Gloves, Elastimold copper or aluminum lug/connector, Vinyl tape, Grounding wire/connector, Cable Support Bracket (optional)

  1. Prepare the Cable

    WARNING: All apparatus must be de-energized during installation. Check that the cable size fits within the kit's specified range. Train the cable into position and cut it to the required length, ensuring sufficient neutral wire length for the grounding connection. Prepare the cable using the specified dimensions, allowing for the terminal lug depth and additional exposed conductor distance for aluminum lugs. Bend the neutral wires back and secure them, typically with vinyl tape.

  2. Install the Lug or Connector

    If using a lug that will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. Remove any excess oxide inhibitor and sharp crimp flashings after crimping.

  3. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent. Do not allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-con insulation shield. Be careful not to reduce the cable insulation diameter below that allowed by the kit.

  4. Install the Termination Body

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease; this fills the step at the semi-con cut-off. Slide the terminator body onto the cable, aligning its skirt with the edge of the cable jacket. Carefully begin to remove the internal core by rotating it counter-clockwise as you pull. Recheck the terminator's position and continue to remove the core. Do not push or pull on the terminator assembly while removing the core.

  5. Connect to System Ground

    Twist the concentric neutral wires together. Securely connect the twisted neutral wires to the system ground. Ensure all connections are tight and secure before energizing the circuit.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.