
ABB Installation Products R2T15J1-N0380 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12…
UPC: 075114379564
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15KV voltage rating for outdoor power applications
- Designed for Concentric Neutral and Jacketed Concentric Neutral cables
- Accommodates cable insulation diameters from 0.64 to 1.12 inches
- Aluminum 2-hole spade connector for 2-1250 kcmil conductors
- Compatible with stranded/compressed 700 kcmil and compact/solid 900 kcmil conductors
Specifications
Application | Cable Termination, Outdoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 700 to 900 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

PCT10240-3
15kV, Single Piece Terminator (Class 1), Two-Hole Spade Lug. Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
R2IT15J1-N0380
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 750 Stranded/Compressed or 900 Compact/Solid
69TCT23NNNNNNBN
69kV, Transmission Cable Terminator, Base and Top Module, Housing Size 3 - Bore Diameter 1.975 inch, Type of Connection - None, Connector Type - None, Conductor Size - None, Metallic Screen Kit - None, Armour Kit - Heat Shrink, No Bracket Required
R2T15M4-N2360-B3
15 kv, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650/Compact 750, Cable Mounting Bracket B3 - Material Stainless Steel - Size - 1.45 inch to 1.95 inch (37mm - 50mm)
R2T15M4N2360
15 kV, Cable Terminator Ranger2, Outdoor, Cable Type - Tape Shield/Wire Shield/UniShield, Insulation Range 4 - 1.30 inch to 2.10 inch (33 mm to 53 mm), Connector Type N2 - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code 360 - Compressed 650 kcmil or Compact 750 kcmil.
R2IT15J1-N0330
Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
69TCT322130PABN
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 2, Connection Type 2 - 2 Hole NEMA, Connector Type - Aluminum, Conductor Size Code 30P, Metallic Screen Kit - Flat Braid, Armour Kit - Heat Shrink, No Bracket Required
R2T15J2N0270-B1
Ranger 2 Terminator, Outdoor, 15kV, Concentric Neutral/Jacketed Concentric Neutral Cable Type, Insulation Range .84 -1.38 inch (21-35mm) Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil. 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. Includes Stainless Steel Cable Mounting Bracket Size - 0.80 to 1.25 inch.Frequently Asked Questions
What is the maximum design voltage to ground for R2T15?
The maximum design voltage to ground for the R2T15 termination is 9.5 kV.
What is the voltage rating of the R2T15 termination?
The R2T15 termination has a voltage rating of 15 kV.
What cable sizes are compatible with R2T15?
The R2T15 termination accommodates cable sizes from #2 AWG through 1250 kcmil.
What cable insulation diameters does R2T15 cover?
The R2T15 termination covers insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).
What is the operating ambient temperature range?
The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What power system frequencies does R2T15 support?
The R2T15 termination supports power system frequencies ranging from 48 to 62 Hz.
What is the IEEE classification for the R2T15 outdoor termination?
The IEEE classification for the R2T15 outdoor termination is Class 1A.
What is the maximum altitude for R2T15 installation?
The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).
What is the creepage distance for the R2T15?
The creepage distance for the R2T15 termination is 15.0 inches (381 mm).
What is the minimum strike distance for the R2T15?
The minimum strike distance for the R2T15 termination is 11.4 inches (381 mm).
How to Install 15kV & 28kV Ranger 2 Cable Termination
Complete installation guide for 15kV & 28kV Ranger 2 Cable Terminations for indoor/outdoor applications on concentric and jacketed concentric neutral cables. Ensure all apparatus are de-energized and installed by competent personnel trained in high voltage safety practices.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Rags or wipes
Supplies needed:
Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Protective gloves, Connector (optional), Cable Support Bracket (optional), Vinyl tape, Binding wire, Elastimold copper or aluminum lugs, Silicone grease
- Perform Pre-Installation Checks
Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.
- Prepare Cable for Termination
Confirm the cable size fits within the kit range. Train the cable into position and cut to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the dimensions shown in the instructions, accounting for terminal lug depth and additional exposed conductor distance for crimping growth. Wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching 50%, and cut flush. Bend neutral wires back over the mastic, press them in, and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and previously applied mastic, stretching 50%, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.
- Install and Crimp Lug or Connector
Ensure the termination assemblies are compatible with the chosen lug. If using lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector/lug and crimp it according to directions, ensuring not to crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive must be used, apply only aluminum oxide abrasive (grit 120 or finer) to the insulation, ensuring not to reduce the cable insulation diameter below the kit's allowed range. Do not use abrasive on the semi-con insulation shield.
- Install Termination Body
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape to build up the band equal to the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, align it with the forward edge of the mastic seal, and carefully remove the core by unwinding counter-clockwise from the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal, and do not push or pull on the assembly during core removal.
- Complete Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.