Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2IT15M2N0270 - Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 / Compact or Solid 250.

ABB Installation Products R2IT15M2N0270 Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38…

UPC: 783786055289


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 R2IT15M2N0270 is a 15 kV indoor cable termination designed for reliable performance in demanding industrial and utility applications. This termination utilizes shrink-fit technology to accommodate a wide range of cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm), specifically covering #2 AWG through 1250 kcmil conductors. The R2IT15M2N0270 model is optimized for cable insulation diameters between 0.84 and 1.38 inches and features an aluminum 2-hole spade terminal compatible with conductor sizes from #2 AWG to 1250 kcmil, supporting both stranded/compressed (4/0 AWG) and compact/solid (250 kcmil) configurations. Its non-tracking silicone housing offers superior memory and weathering characteristics, ensuring long-term service in indoor environments. The design simplifies installation with common procedures and field-removable components. It meets IEEE 48 standards and accommodates popular XLP and EPR cable types with tape shield, wire shield, and unshielded constructions. The termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C) and is suitable for altitudes up to 3300 feet (1005 m). Optional silicone sleeves are available for increased creepage or wildlife protection, and optional connectors include copper stem, one-hole, and two-hole spade configurations. The Ranger2 termination can be mounted free-hanging or with an optional bracket, making it suitable for restricted spaces or applications requiring free hanging. This product is part of the ABB Ranger2 termination series, offering a streamlined solution for medium-voltage cable terminations.
  • 15 kV voltage rating for indoor applications.
  • Accommodates cable insulation diameters from 0.84 to 1.38 inches.
  • Aluminum 2-hole spade terminal for #2 AWG to 1250 kcmil conductors.
  • Non-tracking silicone housing for durability and weather resistance.
  • Meets IEEE 48 standards with a 110 kV crest BIL rating.

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
4/0 AWG , 250 kcmil
Connection Type
2-Hole Spade, Screw Terminal
Connection Type
2-Hole Spade
Earthing
Products Includes Their Own Grounding System
Frequency
48-62 Hz
Material
Aluminum
Material
Aluminum, Silicone
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Field-removable, Restricted spaces, Free hanging
Mounting Type
Indoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84-1.38 inch
Size
0.84-1.38 inches (cable insulation diameter), #2-1250kcmil (conductor size)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10270-3

15kV, Single Piece Terminator (Class 1), Two Hole Spade Lug. Power Cable Termination, Conductor Size - 4/0 Stranded/Compressed, Use for Insulation Diameter Range from .640 to 1.070 inches.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 1-Hole Spade connector for 500 kcmil

R2IT15M2-H0250

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 1-Hole Spade connector for 500 kcmil
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 250 / Compact or Solid 300.

R2IT15M2N0280

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Aluminum 2-Hole Spade #2-1250kcmil, Stranded or Compressed 250 / Compact or Solid 300.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2IT15M2-N0300

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 300 kcmil stranded or 350 kcmil Solid

R2IT15M2-N0290

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 300 kcmil stranded or 350 kcmil Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 400 kcmil Stranded or 500 kcmil Solid

R2IT15M2-N0310

Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 400 kcmil Stranded or 500 kcmil Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 400.

R2IT15M1N2300

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, Copper 2-Hole Spade #2-1250kcmil, Stranded or Compressed 350/ Compact or Solid 400.
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

R2IT15M1-N0240

Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0.

Frequently Asked Questions

What is the minimum strike distance of the R2IT15?

The minimum strike distance for the R2IT15 termination is 8.4 in (213 mm).

What is the voltage rating of the R2IT15 termination?

The R2IT15 cable termination has a voltage rating of 15 kV. Its maximum design voltage to ground is 9.5 kV.

What cable sizes are compatible with R2IT15 terminations?

These terminations accommodate cable sizes from #2 AWG through 1250 kcmil. They cover insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).

What is the operating temperature range for R2IT15?

The R2IT15 cable termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2IT15 installation?

The R2IT15 cable termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the IEEE classification for the R2IT15 termination?

The R2IT15 cable termination has an IEEE classification of Indoor = Class 2.

What is the power system frequency range for R2IT15?

The R2IT15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

What are the available sizes for the R2IT15 termination series?

The R2IT15 termination series is available in sizes 1, 2, and 4.

What is the Coronal Extinction Voltage for R2IT15?

The Coronal Extinction Voltage (Partial Discharge) for the R2IT15 termination is 13 kV (≤ 3pC).

What is the Lightning Impulse Withstand Voltage?

The Lightning Impulse (BIL Dry 110 Withstand) for the R2IT15 termination is 110 kV Crest.

How to Install the 15kV Ranger 2 Shrink-Fit Silicone Rubber Termination for Tape Shielded Cables

This guide provides step-by-step instructions for the safe and proper installation of the 15kV Ranger 2 Shrink-Fit Silicone Rubber Termination on tape shielded cables for indoor applications.

Estimated time: 1h 30m

Tools needed:

Cable preparation tools, Crimping tool, Solvent applicator pads, Abrasive (aluminum oxide, grit 120 or finer), Utility knife or scissors

Supplies needed:

15kV Ranger 2 Shrink-Fit Silicone Rubber Termination kit, Preformed Ground Braid, Constant Force Spring, Silicone Lubricant, Copper Foil Tape, Vinyl Tape, Cable connector/lug, Cleaning solvent, Safety gloves

  1. De-energize and Prepare Cable

    WARNING: Ensure all apparatus is de-energized before beginning installation. Failure to do so will result in serious or fatal injury. Verify the cable size is compatible with the termination kit using the provided chart. Train the cable into its final position and cut it to the required length, allowing for terminal lug depth and growth allowance. Prepare the cable by removing the jacket (9-1/4" / 235mm), tape shield (3/4" / 19mm), and semi-conductive layer (3/4" / 19mm exposed), according to the specified dimensions. Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install Ground Braid

    Wrap one band of vinyl tape around the cable jacket 1/4" (6mm) from the jacket end; this serves as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape marker. Secure the ground braid to the cable jacket using additional vinyl tape. Apply a second vinyl tape band directly over the original marker and ground braid solder block, maintaining the 1/4" (6mm) dimension. Wrap the ground braid around the cable tape shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring, wrapping the spring in the same direction as the braid. Cinch the spring after the final winding. Secure the constant force spring with two wraps of vinyl tape.

  3. Install Lug or Connector

    Before crimping, check that the termination assembly will fit over the selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to the manufacturer's instructions. Do not crimp the last 3/8" to 1/2" of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings or edges after crimping.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with solvent-saturated pads. WARNING: Do not allow the solvent to touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not on the semi-conductive shield. Ensure that the cable insulation diameter is not reduced below the kit's specifications.

  5. Install and Ground Termination

    Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the cut-off point. Slide the termination body onto the cable, aligning its edge with the forward edge of the vinyl tape marker. Carefully begin to remove the termination's core by pulling counter-clockwise. Recheck the termination's position and continue removing the core. WARNING: Do not push or pull on the termination assembly while removing the core. Connect the ground braid securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.