Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2IT15M1-N2240-B1 - Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - Stainless Steel, 0.80 to 1.25 inch.

ABB Installation Products R2IT15M1-N2240-B1 Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114407960


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Indoor Cable Termination (SKU: R2IT15M1-N2240-B1) is a 15kV-rated termination designed for indoor applications, engineered to meet IEEE 48 standards for reliable long-term service. This termination accommodates tape shield, wire shield, and unshielded cables with insulation diameters ranging from 0.64 inches to 1.12 inches, covering conductor sizes from #2 AWG to 1250 kcmil. The termination features a copper 2-hole spade connector, optimized for stranded or compressed 1/0 and 2/0 compact or solid conductors. A stainless steel cable mounting bracket (adjustable from 0.80 to 1.25 inches) ensures secure installation in restricted spaces or free-hanging configurations. The non-tracking silicone housing provides superior weathering resistance and memory, while the field-removable center core simplifies installation and maintenance. The termination operates across an ambient temperature range of -22°F to +149°F (-30°C to +65°C) and supports power system frequencies from 48 to 62 Hz. Ideal for industrial environments where dependable cable termination is critical, the Ranger2 series minimizes model proliferation with three sizes covering the full cable range. Optional silicone sleeves are available for enhanced creepage or wildlife protection.
  • 15kV indoor termination meeting IEEE 48 standards
  • Accommodates tape shield, wire shield, and unshielded cables (0.64"–1.12" insulation)
  • Copper 2-hole spade connector for #2 AWG to 1250 kcmil conductors
  • Stainless steel mounting bracket (0.80"–1.25" diameter range)
  • Non-tracking silicone housing with field-removable center core

Specifications

Application
Cable Termination, Indoor Application, 15kV
Cable Type
Copper Tape Shielded Wire
Conductor Size
1/0 STR AWG , 1/0 COMPR AWG , 2/0 SOL AWG , 2/0 COMPT AWG
Connection Type
2-Hole Spade
Current Rating
1250 A
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting Type
Indoor
NEMA Color
GreySlate
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.64 - 1.12 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction. Cable Mounting Bracket
Standard
IEEE 48
Type
Cable Termination - Indoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.

PCT10240-4

15kV, Single Piece Terminator (Class 1), includes Universal Aluminum Rod Contact as standard, Power Cable Termination, Conductor Size - 1/0 Stranded/Compressed or 2/0 Compact/Solid, Use for Insulation Diameter Range from .640 to 1.070 inches.
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT302233PNAN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

R2T28J4-N0330

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.

R2T28M4-N0460

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.

R2T28J2-N0230

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T28M2-N0250

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0 /Compact or Solid 2/0, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28J2T0240B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0 /Compact or Solid 2/0, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0

R2T28M2-N0260

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0

Frequently Asked Questions

What is the voltage rating for the ABB Ranger2 termination?

The ABB Ranger2 termination is rated for 15kV.

What cable insulation sizes does this termination support?

This termination supports cable insulation sizes ranging from 0.64 inches to 1.12 inches.

What types of cables can be terminated with the Ranger2?

The Ranger2 termination is suitable for tape shield, wire shield, and unshielded cables.

What is the conductor size range for the copper spade connector?

The copper 2-hole spade connector is designed for conductor sizes from #2 AWG to 1250 kcmil.

What conductor codes are compatible with this termination?

This termination is compatible with conductor code 240 (stranded or compressed 1/0) and 2/0 (compact or solid).

What is the size range for the included cable mounting bracket?

The stainless steel cable mounting bracket accommodates cable diameters from 0.80 inches to 1.25 inches.

How to Install the 15kV Ranger 2 Shrink Fit Silicone Rubber Termination (R2IT15M Series) on Tape Shielded Cables

This guide provides detailed instructions for the safe and correct installation of the 15kV Ranger 2 Shrink Fit Silicone Rubber Termination, specifically for R2IT15M series kits used with tape shielded cables in indoor applications. It covers cable preparation, ground braid installation, lug connection, cleaning, and final termination installation.

Estimated time: 1h 30m

Tools needed:

Cable knife or cutter, Measuring tape, Wire strippers, Crimping tool, Cleaning pads, Aluminum oxide abrasive (120 grit or finer, optional)

Supplies needed:

15kV Ranger 2 Shrink Fit Silicone Rubber Termination Kit (includes termination, preformed ground braid, constant force spring, lubricant, copper foil tape, gloves), Vinyl electrical tape, Terminal lug or connector, Cleaning solvent, Silicone grease

  1. De-energize and Prepare Cable

    DANGER: Ensure all apparatus is de-energized before beginning installation. Verify the cable size is compatible with the termination kit using the Termination Selection Chart. Train the cable into its final position and cut it to the required length. Prepare the cable by removing the jacket, tape shield, and semi-conductive layer according to the specified dimensions (9-1/4" (235mm) jacket removal, 3/4" (19mm) tape shield, 3/4" (19mm) minimum exposed semi-con, plus allowance for terminal lug depth and aluminum lug growth). Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install Ground Braid

    Wrap one band of vinyl tape around the cable jacket, 1/4" (6mm) from the jacket end, to serve as a marker. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the vinyl tape marker. Secure the ground braid to the cable jacket with vinyl tape. Apply a second vinyl tape band directly over the original tape marker and the ground braid solder block, maintaining the 1/4" (6mm) dimension. Wrap the ground braid around the cable tape shield for one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid and cinch it after the final winding. Secure the constant force spring with two wraps of vinyl tape.

  3. Install Terminal Lug or Connector

    Before crimping, check that the termination assembly will fit over the selected lug. If not, slide the termination body onto the cable before installing the lug. Do not remove the core at this time. Position the terminal lug or connector and crimp it according to the manufacturer's instructions. Ensure the last 3/8" to 1/2" of the connector is not crimped. Remove any excess oxide inhibitor and all sharp crimp flashings or edges after crimping.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with solvent-saturated pads. WARNING: Do not allow the solvent to touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (120 grit or finer) on the insulation only. Do not use abrasive on the semi-conductive insulation shield, and be careful not to reduce the cable insulation diameter.

  5. Install Silicone Rubber Termination

    Apply a liberal coating of silicone grease to the edge of the semi-conductive insulation shield to fill the step at the semi-con cut-off. Slide the termination body onto the cable. Align the termination edge with the forward edge of the vinyl tape marker. Carefully begin to remove the termination core by pulling counter-clockwise. Recheck the termination position and continue to remove the core. WARNING: Do not push or pull on the termination assembly while removing the core. Connect the ground braid securely to the system ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.