Authorized ABB Distributor (Installation Products)
ABB - Installation Products 69TCT302233PNAN - 69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore Diameter 1.35 inch with Insulation Range of 1.45 to 1.7 inch, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P: 0.781 - 0.815 inch, Metallic Screen Kit - Not Required, Armor Kit - Jacketing Tape and Mastic, No Bracket Required

ABB Installation Products 69TCT302233PNAN 69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore…

UPC: 075114431927


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 69kV Transmission Cable Terminator (SKU: 69TCT302233PNAN) is a high-voltage termination solution engineered for 69kV power transmission systems. This terminator features a Housing Size 0 with a precise 1.35-inch bore diameter, designed to accommodate insulation ranges from 1.45 to 1.7 inches. The unit is optimized for copper conductors, utilizing a Connection Type 2, 2-Hole NEMA configuration for secure and reliable electrical connections. Key specifications include a conductor size code of 33P, corresponding to a diameter range of 0.781 to 0.815 inches. The terminator supports a continuous current rating of 900A for copper applications, making it suitable for high-power transmission environments. The unit does not require a metallic screen kit, simplifying installation. For enhanced mechanical protection, it includes an Armor Kit featuring jacketing tape and mastic, safeguarding against environmental factors and physical damage. No additional bracket is required for installation, reducing setup complexity. This terminator is part of ABB's ComboT series, which includes various kit types such as the Basic ComboT elbow reducing tap plug (BCETP) and ComboT connecting plug (CCP), providing flexibility for different installation requirements. Optional accessories include shrink-fit jacket seal kits (S or SG3), insulating caps (DRG or BWP), and capacitive test point indicators (5 or 6), enhancing functionality and adaptability to specific operational needs. Ideal for use in substations, transmission lines, and other high-voltage infrastructure where reliable power delivery is essential.
  • 69kV voltage rating for high-voltage transmission systems
  • 900A continuous current rating for copper conductors
  • Housing Size 0 with 1.35" bore diameter, insulation range 1.45-1.7"
  • Connection Type 2, 2-Hole NEMA configuration for secure electrical connections
  • Includes Armor Kit with jacketing tape and mastic for environmental protection

Specifications

Application
Cable Terminations, 69kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
0.781 to 0.815 in
Connection Type
2 Hole NEMA
Earthing
Products Includes Their Own Grounding System
Material
Copper
Mounting
No Bracket Required
Mounting Type
No Bracket Required
Nema Rating
Type 2 - 2 Hole NEMA
Number Of Terminals
(1) Single Phase
Size
Housing Size 0 with Bore Diameter 1.35 inch
Special Features
Molded EPDM Elastomer Housing is Durable under Severe Environmental Conditions. Lightweight and easy to Handle
Standard
IEEE 48 and IEC-840
Type
Cable Termination
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required

69TCT312233PAAN

69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid

R2T28J4-N0330

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.

R2T28M4-N0460

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.

R2T28J2-N0230

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T28M2-N0250

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0 /Compact or Solid 2/0, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch

R2T28J2T0240B2

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0 /Compact or Solid 2/0, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0

R2T28M2-N0260

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1/0 /Compact or Solid 2/0

R2T28J2-N2240

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1/0 /Compact or Solid 2/0

Frequently Asked Questions

How can I order the 69TCT Terminator?

To order the 69TCT Terminator, provide cable cut sheet information and contact Thomas & Betts at 901-252-5000.

What items are included in a 69TCT Terminator kit?

Each 69TCT Terminator kit includes one TCT Terminator, an instruction sheet (IS-0873), a conductive paint package (138-13), and two mastic tapes (138-189).

How long does it take to install the 69TCT Terminator?

Installation of the 69TCT Terminator can be accomplished in 45 minutes after cable preparation, using the Elastimold TCJ-ATK-U Universal Assembly Tool.

What cable types and sizes are compatible with 69TCT?

It is designed for solid dielectric cables with insulation diameters up to 3.400 inches and accommodates conductor sizes from 90mm2 (4/0) to 1700mm2 (3500 kcmil).

What is the application of the 69TCT Terminator?

The 69TCT Terminator provides a Class 1 termination for cable systems rated through 69kV class.

What is the maximum working voltage for this terminator?

The 69TCT Terminator has a maximum working voltage of 72.5 kV.

What is the nominal voltage of the 69TCT Terminator?

The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.

How long does it take to install the 69TCT Terminator?

Installation of the 69TCT Terminator can be accomplished in 45 minutes after cable preparation, using the Elastimold TCJ-ATK-U Universal Assembly Tool.

What is the nominal voltage of the 69TCT Terminator?

The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.

What is the maximum working voltage for this terminator?

The 69TCT Terminator has a maximum working voltage of 72.5 kV.

How to Install the 69TCT302233PNAN Outdoor Transmission Cable Termination

Step-by-step guide for installing the ELASTIMOLD TCT outdoor transmission cable termination.

Estimated time: 1h 30m

Tools needed:

Hose clamp, Cable cleaner, Wirebrush, Soldering iron, Heat gun

Supplies needed:

Heat shrink sleeve, Vinyl tape marker, Semi-conductive paint, Mastic tape, Silicone tape, #12 AWG copper drain wire, Spade contact, Connector, Winch assembly, Housing clamp, Adapter plates, Cable clamp, Lubricant

  1. Prepare the cable end

    Straighten the cable and place it in the final position. Square cut the cable to the specified depth (X). Remove the outer jacket to the specified distance, exposing the cable shield. Slide on a heat shrink sleeve. Remove the shield to the specified distance. Remove the non-metallic screen, ensuring not to nick the insulation. Chamfer the non-metallic screen edge. Square cut the cable insulation and chamfer its edge.

  2. Clean and paint the cable

    Clean the cable insulation and non-metallic screen with cable cleaner. Apply a vinyl tape marker at the specified distance. Paint the exposed insulation and screen with semi-conductive paint. Remove the vinyl tape marker within 5 to 15 minutes, ensuring a smooth, square edge for the paint. Allow the paint to dry for 60 minutes.

  3. Prepare for termination assembly

    Place a vinyl tape marker onto the cable non-metallic shield, 2 inches from the edge of the paint. Assemble the cable clamp at least 55 inches back from the conductor and tighten securely. Place the winch assembly in front of the cable clamp and attach stationary hooks. Attach adapter plates to the housing clamp with bolts and assemble the housing clamp around the terminator base section. Extend steel cables on the winch assembly until hooks reach the housing clamp and connect them. Lubricate the cable in the specified area.

  4. Assemble the terminator

    Assemble the terminator base section on the cable approximately 12 inches from the end. Release tension on the steel cables and extend the housing clamp. Position the terminator module section in the housing clamp. Continue assembling mated units until the terminator base section is flush with the tape marker. Remove the winch assembly, housing clamp, adapter plate, and cable clamp.

  5. Connect the conductor and apply mastic

    Remove the tape marker on the insulation shield. Remove the cut section of insulation to expose the conductor. Wirebrush the conductor and immediately insert it into the spade contact. Crimp the connector according to the provided instructions. Remove any excess inhibitor. Apply two layers of mastic: one at the end of the stress cone and one 2 inches back from the end of the cable jacket.

  6. Install drain wire and heat shrink

    Install the scintillation ring and the #12 AWG copper drain wire. Solder the flat braid and the drain wire to the shield. Apply a second layer of mastic over the drain wire and the flat braid. Slide the heat shrink sleeve up to the grounding eye of the base of the terminator. Apply heat to the sleeve, starting in the middle and moving towards the ends, until mastic sealer squeezes from the ends. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.

  7. Mount the terminated cable

    Mount the terminated cables to the supporting structure, ensuring sufficient clearance between the terminator stress cone base and the supporting structure. Follow all applicable work rules and safety practices.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.