ABB Installation Products 69TCT302233PNAN 69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 0 with Bore…
UPC: 075114431927
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 69kV voltage rating for high-voltage transmission systems
- 900A continuous current rating for copper conductors
- Housing Size 0 with 1.35" bore diameter, insulation range 1.45-1.7"
- Connection Type 2, 2-Hole NEMA configuration for secure electrical connections
- Includes Armor Kit with jacketing tape and mastic for environmental protection
Specifications
Application | Cable Terminations, 69kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 0.781 to 0.815 in |
Connection Type | 2 Hole NEMA |
Earthing | Products Includes Their Own Grounding System |
Material | Copper |
Mounting | No Bracket Required |
Mounting Type | No Bracket Required |
Nema Rating | Type 2 - 2 Hole NEMA |
Number Of Terminals | (1) Single Phase |
Size | Housing Size 0 with Bore Diameter 1.35 inch |
Special Features | Molded EPDM Elastomer Housing is Durable under Severe Environmental Conditions. Lightweight and easy to Handle |
Standard | IEEE 48 and IEC-840 |
Type | Cable Termination |
Voltage Rating | 69 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

69TCT312233PAAN
69kV, Transmission Cable Terminator, Base and Two Top Module, Housing Size 1, Connection Type 2 - 2 Hole NEMA, Connector Type - Copper, Conductor Size Code 33P, Metallic Screen Kit - Flat Braid, Armour Kit - Jacketing Tape and Mastic, No Bracket Required
R2T28J4-N0330
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 500 Stranded/Compressed or 600 Compact/Solid
R2T28M4-N0460
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 460 -Stranded or Compressed 1500 Compact or Solid 1600.
R2T28J2-N0230
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
R2T28M2-N0250
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
R2T28J2T0240B2
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0 /Compact or Solid 2/0, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inch
R2T28M2-N0260
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 3/0 /Compact or Solid 4/0
R2T28J2-N2240
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Copper 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1/0 /Compact or Solid 2/0Frequently Asked Questions
How can I order the 69TCT Terminator?
To order the 69TCT Terminator, provide cable cut sheet information and contact Thomas & Betts at 901-252-5000.
What items are included in a 69TCT Terminator kit?
Each 69TCT Terminator kit includes one TCT Terminator, an instruction sheet (IS-0873), a conductive paint package (138-13), and two mastic tapes (138-189).
How long does it take to install the 69TCT Terminator?
Installation of the 69TCT Terminator can be accomplished in 45 minutes after cable preparation, using the Elastimold TCJ-ATK-U Universal Assembly Tool.
What cable types and sizes are compatible with 69TCT?
It is designed for solid dielectric cables with insulation diameters up to 3.400 inches and accommodates conductor sizes from 90mm2 (4/0) to 1700mm2 (3500 kcmil).
What is the application of the 69TCT Terminator?
The 69TCT Terminator provides a Class 1 termination for cable systems rated through 69kV class.
What is the maximum working voltage for this terminator?
The 69TCT Terminator has a maximum working voltage of 72.5 kV.
What is the nominal voltage of the 69TCT Terminator?
The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.
How long does it take to install the 69TCT Terminator?
Installation of the 69TCT Terminator can be accomplished in 45 minutes after cable preparation, using the Elastimold TCJ-ATK-U Universal Assembly Tool.
What is the nominal voltage of the 69TCT Terminator?
The nominal voltage (Uo/U) for the 69TCT Terminator is 40kV/59kV.
What is the maximum working voltage for this terminator?
The 69TCT Terminator has a maximum working voltage of 72.5 kV.
How to Install the 69TCT302233PNAN Outdoor Transmission Cable Termination
Step-by-step guide for installing the ELASTIMOLD TCT outdoor transmission cable termination.
Estimated time: 1h 30m
Tools needed:
Hose clamp, Cable cleaner, Wirebrush, Soldering iron, Heat gun
Supplies needed:
Heat shrink sleeve, Vinyl tape marker, Semi-conductive paint, Mastic tape, Silicone tape, #12 AWG copper drain wire, Spade contact, Connector, Winch assembly, Housing clamp, Adapter plates, Cable clamp, Lubricant
- Prepare the cable end
Straighten the cable and place it in the final position. Square cut the cable to the specified depth (X). Remove the outer jacket to the specified distance, exposing the cable shield. Slide on a heat shrink sleeve. Remove the shield to the specified distance. Remove the non-metallic screen, ensuring not to nick the insulation. Chamfer the non-metallic screen edge. Square cut the cable insulation and chamfer its edge.
- Clean and paint the cable
Clean the cable insulation and non-metallic screen with cable cleaner. Apply a vinyl tape marker at the specified distance. Paint the exposed insulation and screen with semi-conductive paint. Remove the vinyl tape marker within 5 to 15 minutes, ensuring a smooth, square edge for the paint. Allow the paint to dry for 60 minutes.
- Prepare for termination assembly
Place a vinyl tape marker onto the cable non-metallic shield, 2 inches from the edge of the paint. Assemble the cable clamp at least 55 inches back from the conductor and tighten securely. Place the winch assembly in front of the cable clamp and attach stationary hooks. Attach adapter plates to the housing clamp with bolts and assemble the housing clamp around the terminator base section. Extend steel cables on the winch assembly until hooks reach the housing clamp and connect them. Lubricate the cable in the specified area.
- Assemble the terminator
Assemble the terminator base section on the cable approximately 12 inches from the end. Release tension on the steel cables and extend the housing clamp. Position the terminator module section in the housing clamp. Continue assembling mated units until the terminator base section is flush with the tape marker. Remove the winch assembly, housing clamp, adapter plate, and cable clamp.
- Connect the conductor and apply mastic
Remove the tape marker on the insulation shield. Remove the cut section of insulation to expose the conductor. Wirebrush the conductor and immediately insert it into the spade contact. Crimp the connector according to the provided instructions. Remove any excess inhibitor. Apply two layers of mastic: one at the end of the stress cone and one 2 inches back from the end of the cable jacket.
- Install drain wire and heat shrink
Install the scintillation ring and the #12 AWG copper drain wire. Solder the flat braid and the drain wire to the shield. Apply a second layer of mastic over the drain wire and the flat braid. Slide the heat shrink sleeve up to the grounding eye of the base of the terminator. Apply heat to the sleeve, starting in the middle and moving towards the ends, until mastic sealer squeezes from the ends. Connect the flat braid to the system ground. Seal the cable end with mastic tape between the contact and cable insulation. Apply two half-lapped layers of silicone tape covering the crimp connector, mastic tape, and the upper portion of the terminator skirt.
- Mount the terminated cable
Mount the terminated cables to the supporting structure, ensuring sufficient clearance between the terminator stress cone base and the supporting structure. Follow all applicable work rules and safety practices.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.