ABB Installation Products R2IT15J1-N0300 Indoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed…
UPC: 075114304818
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating for medium voltage applications
- Designed for Concentric Neutral and Jacketed Concentric Neutral cable types
- Accommodates insulation diameters from 0.64 inch to 1.12 inch
- Aluminum 2-hole spade connector
- Compatible with 350 kcmil stranded/compressed or 400 kcmil compact/solid conductors
Specifications
Application | Cable Termination, Indoor Application, 15kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 350 to 400 kcmil |
Connection Type | 2-Hole Spade |
Current Rating | 1250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Mounting | Product Need to have Cable Holder (not included) |
Mounting Type | Indoor |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 0.64 inch - 1.12 inch (Insulation Range) |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Indoor - Ranger2 |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T15J1-N0300
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
R2IT15M1-N0300
Ranger2 Termination. Type - Indoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
R2T35M2N2250-B2
Outdoor, Ranger2 Termination, 35kV, Tape Shield/Wire Shield/UniShield Cable Type, Insulation Range - .84-1.38 inch (21-35mm). Connector Type Copper 2-Hole Spade #2-1250 kcmil. Conductor - 2/0 Stranded/Compressed or 3/0 Compact/Solid. Cable Mounting Bracket Material - Stainless Steel, Size 1.10-1.50 inch (28-38mm).
R2T35M2T0240
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid
R2T35M4N0300-B3
Ranger2 Termination. Type - Indoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400. Cable Mounting Bracket Material Stainless Steel - 1.45 inch to 1.95 inch (37-50mm).
R2T35M2-H0330-B1
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 1-Hole Spade connector for #2-500 kcmil, Stranded or Compressed 500/ Compact or Solid 600 . Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-35mm)
R2IT15M1-N0210
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. #1 Stranded or 1/0 Solid. #2 Solid.
R2T35J4-T0270-B3
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inchFrequently Asked Questions
What is the voltage rating of the R2IT15 termination?
The R2IT15 cable termination has a voltage rating of 15 kV.
What is the creepage distance of the termination?
The creepage distance of the R2IT15 termination is 8.4 in (213 mm).
What cable sizes are compatible with this termination?
It covers #2 AWG through 1250 kcmil cables with insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).
What is the operating temperature range for this termination?
The ambient temperature range for operation is -22 to +149 °F (-30 to +65 °C).
What is the maximum altitude for installation?
The maximum altitude range for installation is 3300 feet (1005 m).
What is the IEEE classification for this indoor termination?
The R2IT15 indoor termination has an IEEE Classification of Class 2.
What is the power system frequency range?
The power system frequency range for this termination is 48 to 62 Hz.
What is the maximum design voltage to ground?
The maximum design voltage to ground for the R2IT15 termination is 9.5 kV.
What is the maximum altitude for installation?
The maximum altitude range for installation is 3300 feet (1005 m).
What cable sizes are compatible with this termination?
It covers #2 AWG through 1250 kcmil cables with insulation diameters from 0.64 in (16 mm) to 2.10 in (53 mm).
How to Install the 15kV Ranger 2 Cable Terminator (Indoor)
This guide provides step-by-step instructions for the indoor installation of the 15kV Ranger 2 Cable Terminator, including cable preparation, lug installation, cleaning, and final termination setup. WARNING: All apparatus must be de-energized during installation. Installation should only be performed by competent personnel trained in high voltage safety practices.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Measuring tape or ruler, Cleaning cloths or wipes
Supplies needed:
15kV Ranger 2 Cable Terminator Kit (includes termination, lubricant, gloves), Elastimold copper or aluminum lugs (or compatible connector), Approved solvent (for cable cleaning), Aluminum oxide abrasive (grit 120 or finer, if needed), Vinyl tape, System ground connection materials
- Verify Cable Compatibility and Prepare Cable
Check that the cable size fits within the kit's specified range as shown in the Termination Selection Chart. Train the cable into its final position and cut it to the required length, ensuring sufficient neutral wire length for the grounding connection. Prepare the cable according to the provided dimensions, allowing for the depth of the terminal lug and additional exposed conductor distance for aluminum lugs/connectors. Bend the neutral wires back and secure them, potentially using vinyl tape as indicated.
- Install the Lug or Connector
Ensure the termination assemblies are compatible with the chosen lug. If using a lug that won't fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to the manufacturer's directions, leaving the last 1/4 to 3/8 inch uncrimped. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation thoroughly with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, avoiding the semi-con insulation shield. Be careful not to reduce the cable insulation diameter below the kit's allowed specifications.
- Install the Termination Body
Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the semi-con cut-off. Slide the terminator body onto the cable, aligning its skirt with the edge of the cable jacket. Carefully begin to remove the core by rotating the lead counter-clockwise while pulling. Recheck the terminator position and continue removing the core. Do not push or pull on the terminator assembly during core removal.
- Connect Neutral Wires to System Ground
Twist the concentric neutral wires together firmly. Connect these twisted neutral wires securely to the system ground, ensuring a reliable and safe grounding connection.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.