ABB - Installation Products R2T35J4-T0270-B3 - Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

ABB Installation Products R2T35J4-T0270-B3 Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10…

UPC: 783786025039


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T35J4-T0270-B3) is a field-proven 35kV outdoor termination kit engineered for medium-voltage power distribution systems. This termination leverages shrink-fit technology and Elastimold’s pull-down jacket seal to deliver a compact, high-reliability solution for terminating concentric neutral and jacketed concentric neutral cables with insulation diameters from 1.30 inches to 2.10 inches. The kit’s universal aluminum barrel accommodates both aluminum and copper conductors, supporting stranded or compressed 4/0 conductors as well as solid or compact 250 conductors. A pre-installed #2-4/0 copper wire lead ensures proper grounding and connection. The termination features a non-tracking silicone housing with superior weathering characteristics and eight sheds for enhanced creepage and strike distances. The field-removable center core simplifies installation, while the stainless steel mounting bracket provides adjustable mounting for diameters from 1.45 inches to 1.95 inches. Designed for outdoor environments, the Ranger2 termination withstands lightning impulse voltages up to 200 kV crest and maintains 80 kV for 10 seconds under wet conditions. The housing is optimized for restricted spaces and free-hanging applications, making it suitable for utility, industrial, and renewable energy installations. Optional insulating silicone sleeves are available for increased creepage or wildlife protection. The termination supports popular XLP and EPR cable types and shield constructions, covering a cable range from #2 AWG to 1250 kcmil with minimal model variation.
  • 35kV outdoor termination kit for concentric neutral and jacketed concentric neutral cables
  • Insulation diameter range: 1.30–2.10 inches (33–53 mm)
  • Universal aluminum barrel supports aluminum or copper conductors (#2–4/0 stranded/compressed, 250 solid/compact)
  • Non-tracking silicone housing with 8 sheds for superior creepage and strike distances
  • Stainless steel mounting bracket with 1.45–1.95 inch adjustable range

Specifications

Application
Cable Termination, Outdoor Application, 35kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
4/0 AWG , 250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2T35J2-N0270

Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0/ Compact or Solid 250. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

R2T15J2-T0270-B2

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0/ Compact or Solid 250. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded, Conductor Code - 220 -Stranded or Compressed #2, Compact or Solid #1, includes Aluminum 2-Hole Spade connector for 1250 kcmil

R2IT15M1N0220

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded, Conductor Code - 220 -Stranded or Compressed #2, Compact or Solid #1, includes Aluminum 2-Hole Spade connector for 1250 kcmil
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000

R2T35M4N0410

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 650 /Compact or Solid 750

R2T35M4N0350

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 650 /Compact or Solid 750
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600

R2T35M4N0330

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64-1.12 for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade

R2T15J2-N0330

Ranger2 Termination for 15KV indoor application, cable insulation diameter .64-1.12 for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

R2T15J2-N0330-B2

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

Frequently Asked Questions

What is the voltage rating of the R2T35 cable termination?

The R2T35 cable termination has a voltage rating of 35 kV.

What is the maximum design voltage to ground for the R2T35?

The maximum design voltage to ground for the R2T35 termination is 22 kV.

What cable sizes are compatible with the R2T35 termination?

The R2T35 termination accommodates cables from #2 AWG through 1250 kcmil, with insulation diameters from 0.84 in to 2.10 in.

What is the acceptable ambient temperature range for the R2T35?

The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What cable insulation diameters does the R2T35 termination cover?

The R2T (Outdoor) termination covers insulation diameters from 0.84 inches (21.3 mm) to 2.10 inches (53 mm). This accommodates #2 AWG through 1250 kcmil cables.

What is the voltage rating of the R2T35 cable termination?

The R2T35 cable termination has a voltage rating of 35 kV. Its maximum design voltage to ground is 22 kV.

What is the operating temperature range for the R2T35 termination?

The ambient temperature range for the R2T35 termination is -22 to +149 °F (-30 to +65 °C).

What is the operating temperature range for the R2T35 termination?

The ambient temperature range for the R2T35 termination is -22 to +149 °F (-30 to +65 °C).

What is the voltage rating of the R2T35 cable termination?

The R2T35 cable termination has a voltage rating of 35 kV. Its maximum design voltage to ground is 22 kV.

What cable insulation diameters does the R2T35 termination cover?

The R2T (Outdoor) termination covers insulation diameters from 0.84 inches (21.3 mm) to 2.10 inches (53 mm). This accommodates #2 AWG through 1250 kcmil cables.

How to Install the R2T35J4-T0270-B3 35kV Ranger 2 Cable Terminator

This guide provides step-by-step instructions for the safe and proper installation of the R2T35J4-T0270-B3 35kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Vinyl tape, Binding wire, Gloves

Supplies needed:

R2T35J4-T0270-B3 Kit (includes Silicone Rubber Termination Halves, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves), Terminal lug (Elastimold copper or aluminum recommended), Silicone grease, Cable Support Bracket (Optional)

  1. Prioritize Safety and Preparation

    DANGER: De-energize all apparatus before beginning installation or removal. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow instructions can result in serious injury or death. Ensure all local and national work rules are followed. Inspect the kit contents for completeness and damage. Verify all components fit the cable and mating products. Read all instructions thoroughly and have all required tools ready, maintaining cleanliness throughout the procedure.

  2. Prepare the Cable

    Confirm the cable size is within the kit's specified range. Train the cable into its final position and cut it to the required length, ensuring sufficient neutral wire length for the grounding connection. Prepare the cable according to the provided dimensions, allowing for the terminal lug's depth and additional conductor distance for aluminum lug crimping growth (1/4 inch for #1-350, 1/2 inch for 400-650, 3/4 inch for 750-1000 Kcmil). Wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, stretching it to 50%. Cut the mastic flush without overlapping. Bend the neutral wires back over the mastic and press them firmly into it. Secure the neutral wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second band of sealing mastic over the neutral wires and the first mastic band, stretching it to 50%. Cut this band flush without overlapping. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension from the jacket end.

  3. Install the Lug or Connector

    If using a non-Elastimold lug that does not fit through the termination core, slide the termination body onto the cable before installing the lug. Do not remove the core at this stage. Position the connector or lug and crimp it according to the manufacturer's directions. Do not crimp the last 1/4 to 3/8 inch of the connector barrel. After crimping, remove any excess oxide inhibitor and sharp crimp flashings from the lug or connector.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation. Do not use abrasive on the semi-con insulation shield, and ensure the cable insulation diameter is not reduced below the kit's allowed range.

  5. Install the Termination Halves

    Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the lug barrel diameter is equal to or greater than the cable primary insulation, use a maximum of two layers. If smaller, build up the tape to match the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the semi-con cut-off. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top until the core is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is firmly butted against the leading edge of the mastic seal. Do not push or pull the termination assembly during core removal. Using the second termination housing, pull its core down to within one coil of the bottom. Slide this terminator over the cable, overlapping the first terminator by 1-1/2 inches (40mm), and carefully pull its core counter-clockwise to remove it.

  6. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but avoid lubricating the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel using a half-lap configuration. Twist the concentric neutral wires together and securely connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.