ABB Installation Products R2T35M2N2250-B2 Outdoor, Ranger2 Termination, 35kV, Tape Shield/Wire Shield/UniShield Cable Type…
UPC: 075114312394
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV outdoor termination for tape shield, wire shield, and UniShield cables
- Accommodates cable insulation range of .84-1.38 inches (21-35mm)
- Copper 2-hole spade connector for #2-1250 kcmil conductors (2/0 Stranded/Compressed or 3/0 Compact/Solid)
- Includes stainless steel cable mounting bracket (1.10-1.50 inch / 28-38mm)
- ABB Installation Products quality and reliability
Specifications
Application | Cable Termination, Outdoor Application, 35kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 2/0 STR AWG , 2/0 COMPR AWG , 3/0 SOL AWG , 3/0 COMPT AWG |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T35J2-T0250
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead, Stranded or Compressed 2/0 /Compact or Solid 3/0
R2T35M2T0240
Outdoor Ranger2 Cable Termination. 35kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Universal Aluminum Barrel for AL or CU Conductor with Copper Wire Lead #2-4/0, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid
R2T35M4N0300-B3
Ranger2 Termination. Type - Indoor, 35kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400. Cable Mounting Bracket Material Stainless Steel - 1.45 inch to 1.95 inch (37-50mm).
R2T35M2-H0330-B1
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 1-Hole Spade connector for #2-500 kcmil, Stranded or Compressed 500/ Compact or Solid 600 . Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-35mm)
R2IT15M1-N0210
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. #1 Stranded or 1/0 Solid. #2 Solid.
R2T35J4-T0270-B3
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
R2T15J2-T0270-B2
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0/ Compact or Solid 250. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)
R2IT15M1N0220
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64 - 1.12 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded, Conductor Code - 220 -Stranded or Compressed #2, Compact or Solid #1, includes Aluminum 2-Hole Spade connector for 1250 kcmilFrequently Asked Questions
What is the voltage rating of the R2T35 cable termination?
The R2T35 cable termination has a voltage rating of 35 kV.
What is the voltage rating of the R2T35 cable termination?
The R2T35 cable termination has a voltage rating of 35 kV.
What is the voltage rating of the R2T35 cable termination?
The R2T35 cable termination has a voltage rating of 35 kV.
What is the voltage rating of the R2T35 cable termination?
The R2T35 cable termination has a voltage rating of 35 kV.
What cable sizes are compatible with the R2T35 termination?
The R2T35 termination accommodates cables from #2 AWG through 1250 kcmil, with insulation diameters from 0.84 in to 2.10 in.
What is the acceptable ambient temperature range for the R2T35?
The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the maximum design voltage to ground for the R2T35?
The maximum design voltage to ground for the R2T35 termination is 22 kV.
What is the acceptable ambient temperature range for the R2T35?
The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What cable sizes are compatible with the R2T35 termination?
The R2T35 termination accommodates cables from #2 AWG through 1250 kcmil, with insulation diameters from 0.84 in to 2.10 in.
What is the maximum design voltage to ground for the R2T35?
The maximum design voltage to ground for the R2T35 termination is 22 kV.
How to Install the R2T35M 35kV Shrink-fit Silicone Rubber Termination
This guide provides detailed instructions for the safe and proper installation of the R2T35M 35kV Ranger 2 Shrink-fit Silicone Rubber Termination for indoor/outdoor applications with high-K stress relief on tape shield, wire shield, and UniShield® cables.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (120 grit or finer, optional), Soldering iron, Measuring tape or ruler, Gloves
Supplies needed:
R2T35M Silicone Rubber Termination Halves, Lubricant (Silicone Grease), Gray Silicone Rubber Electrical Tape, Sealing Mastic, Preformed Ground Braid, Copper Foil Tape (for tape shielded cables), Constant Force Spring, Terminal Lug or Connector, Vinyl Tape, Scotch® No. 13 Semi-conductive rubber tape (for cloth/paper semi-con shields, optional), Cable Support Bracket (optional)
- De-energize and Prepare Cable
DANGER: De-energize all apparatus in the work area before beginning installation. Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut to the required length. Prepare the cable using the specified dimensions, allowing for terminal lug depth and aluminum lug growth allowance. For tape shielded cables, hold down the tape shield edge with a single wrap of the supplied copper foil tape. For wire shielded cables, bend the leading 1-1/2" (38mm) of exposed shield wires back to the jacket edge. For UniShield® cables, install a constant force spring, pull shield wires through the semi-conductive jacket, remove the spring, bend UniShield® wires back 1" (25mm) onto the cable jacket, and remove the semi-conductive jacket to the specified dimension. Note: Some UniShield® cables have dual-layer semi-conductive jackets; both layers must be removed.
- Install Ground Braid
Wrap one band of mastic around the cable jacket 1/4” (6mm) from the jacket end using 50% stretch. Position the mastic carefully as it serves as a marker for termination positioning, then cut it flush without overlapping. Position the preformed ground braid with the short tail over the cable shield (tape, wire, or UniShield® wires) and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previously applied mastic, maintaining the 1/4” (6mm) dimension, using 50% stretch and cutting flush. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4” (6mm) dimension. Wrap the ground braid around the cable shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring. Wrap the spring in the same direction as the ground braid, cinch (tighten) it after the final winding, and secure the spring with two wraps of vinyl tape. For cloth or paper semi-conductive insulation shields, overwrap the shield with one half-lapped layer of highly stretched semi-conductive rubber tape (e.g., Scotch® No. 13).
- Install Lug or Connector
Check to ensure the termination assembly fits over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug; do not remove the core at this time. Position the connector/lug and crimp it according to the manufacturer’s directions. Do not crimp the last 3/8” to 1/2” of the connector. Remove excess oxide inhibitor and all sharp crimp flashings and edges following crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If an abrasive must be used, apply it only on the insulation (not the semi-conductive insulation shield), using only aluminum oxide abrasive (grit 120 or finer). Be careful not to reduce the cable insulation diameter below that allowed by the kit.
- Install Termination Halves
Create a track-resistant moisture seal between the termination insulator and the lug/connector using the gray silicone rubber electrical tape. Wrap a band of silicone tape around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to form the tape band equal to the insulation diameter; if equal to or greater, the tape band should not exceed 2 layers. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step at the semi-con cut-off. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Continue removing the core, avoiding pushing or pulling on the termination assembly. If using a second housing, carefully pull its core down within 1 coil of the bottom. Slide this termination over the cable and carefully pull the core counterclockwise, overlapping the first termination by 1-1/2” (40mm). Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1” and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground (for wire shielded cables, twist concentric neutral wires together and connect to system ground). Confirm that the High-K step does not exceed 1.5”.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.