ABB - Installation Products K656LR-F0250-SG3 - 15/25kV, 600 Amp Deadbreak Separable WYE Joint Connector with Test Point. Cable Insulation Diameter F - 0.640 - 0.820 inch. Aluminum Compression Connector. Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. Sealing Kit SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

ABB Installation Products K656LR-F0250-SG3 15/25kV, 600 Amp Deadbreak Separable WYE Joint Connector with Test Point. Cable…

UPC: 075114356121


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products K656LR-F0250-SG3 is a 15/25kV, 600 Amp Deadbreak Separable WYE Joint Connector engineered for medium-voltage power distribution systems requiring reliable, submersible cable connections. This connector is designed to terminate 250 kcmil to 2/0 AWG stranded/compressed or 3/0 AWG solid/compact conductors with insulation diameters between 0.640 and 0.820 inches, making it ideal for applications where cable flexibility and size variation are critical. The connector features a cold-shrinkable SG3 sealing kit with copper braid and constant force spring, ensuring watertight, corrosion-resistant performance in harsh environments. Its aluminum compression design delivers secure electrical continuity while maintaining mechanical integrity under continuous 600 Amp loads. The integrated test point enables diagnostic capabilities without de-energizing the system, reducing downtime during maintenance or troubleshooting. Meets ANSI/IEEE Standard 386 for 15kV and 25kV voltage classes, with ratings including 8.3kV phase-to-ground and 14.4kV phase-to-phase for 15kV operation, and 16.2kV phase-to-ground and 28kV phase-to-phase for 25kV operation. The connector also supports momentary 25kA symmetrical fault current for 10 cycles, providing robust protection in fault conditions. Applications include switchgear, transformers, and other high-voltage apparatus where fully shielded, submersible connections are required. Compatible with metallic tape shield or drain wire cables, this WYE joint connector is a critical component for medium-voltage distribution networks prioritizing reliability, safety, and ease of installation.
  • 15/25kV voltage class with 600A continuous current rating
  • Accommodates 250 kcmil to 2/0 AWG stranded/compressed or 3/0 AWG solid/compact conductors
  • Cable insulation diameter range: 0.640–0.820 inches
  • SG3 cold-shrinkable sealing kit with copper braid and constant force spring for watertight performance
  • Integrated test point for diagnostic capabilities without de-energization
  • Meets ANSI/IEEE Standard 386 with 95kV BIL (15kV) and 140kV BIL (25kV) impulse withstand
  • Fully shielded, submersible design for switchgear and high-voltage apparatus
  • Momentary fault current rating: 25kA symmetrical for 10 cycles

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal

K151SR-B0250-S

15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.

162LR-A2220-S

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.
15kV, 600 Amp - 200 Amp Combo T, with Insulated Cap and Sealing Kit. Combo Elbow with bus, stud and cable adapter and lug kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed or Stranded 650, Compacted or Solid 750.

656CEPTM0360DRG-S

15kV, 600 Amp - 200 Amp Combo T, with Insulated Cap and Sealing Kit. Combo Elbow with bus, stud and cable adapter and lug kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed or Stranded 650, Compacted or Solid 750.
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 1.370-1.630 inches (34.8-41.4 mm). Aluminum Conductor Material, Conductor Code 360 - 650 Stranded/Compressed or 750/800 Solid/Compact. No Sealing Kit.

K656CETP-M0360

25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Integral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 1.370-1.630 inches (34.8-41.4 mm). Aluminum Conductor Material, Conductor Code 360 - 650 Stranded/Compressed or 750/800 Solid/Compact. No Sealing Kit.
Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0, Solid 2/0.

K152SR-A0240

Straight Receptacle with Test Point, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0, Solid 2/0.
600 Amp, 15/25 kV, Deadbreak Separable Y Joint package 3-Way with Test Point, (2) Sides Cable Insulation Diameter G - 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0. (1) Side Cable Insulation Diameter K - 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 550. Includes SG1 - Cold-Shrinkable Seal with Copper Rod and Crimp Connector.

K656CY-DP0600536

600 Amp, 15/25 kV, Deadbreak Separable Y Joint package 3-Way with Test Point, (2) Sides Cable Insulation Diameter G - 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0. (1) Side Cable Insulation Diameter K - 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 550. Includes SG1 - Cold-Shrinkable Seal with Copper Rod and Crimp Connector.
25/28kV, 200 Amp, Elbow Connector, Loadbreak, No Sealing Kit, No Test Point, Cable Insulation Diameter .635-.905 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid.

261LR-B5220

25/28kV, 200 Amp, Elbow Connector, Loadbreak, No Sealing Kit, No Test Point, Cable Insulation Diameter .635-.905 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid.
15KV, 200 Amp, Loadbreak Elbow with Sealing Jacket, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed-Stranded 1/0, Solid-Compact 2/0.

161LRJS-D5240

15KV, 200 Amp, Loadbreak Elbow with Sealing Jacket, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed-Stranded 1/0, Solid-Compact 2/0.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground. For the 28kV voltage class, it is 16.2kV phase-to-ground.

What conductor sizes can the K656LR accommodate?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this elbow connector?

The K656LR elbow connector has a continuous current rating of 600 Amps.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL for a 1.2 x 50 microsecond wave.

What is the AC one-minute withstand voltage for the 15kV class?

The AC one-minute withstand voltage for the 15kV voltage class is 34kV.

What is the corona extinction rating for the 28kV voltage class?

The corona extinction rating for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

What is the range of insulation diameters supported by the K656LR?

The K656LR supports cable insulation diameters from 0.640 inches to 1.935 inches.

What is the momentary current rating for the K656LR?

The K656LR has a momentary current rating of 25kA Sym for 10 Cycles.

Can the K656LR be installed or removed while energized?

No, the K656LR can be easily connected or disconnected using standard tools and equipment only in a de-energized state.

What is the purpose of the capacitive test point?

The K656LR features a non-corrosive, capacitive test point for testing purposes.

How to Install K656LR-F0250-SG3 Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of 655/675LR and K655/K675LR deadbreak elbow connectors, designed for high voltage apparatus connections and splicing 600-ampere or 900-ampere systems.

Estimated time: 1h

Tools needed:

Wire strippers, Wire brush, Crimping tool, Hotstick, Suitable voltage sensing device, Torque wrench

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug, Lubricant (silicone), Stud prepack, Crimp chart, Grounding device (optional), 10TL cable shield adapter (optional), No. 14 AWG Copper wire (or equivalent), Suitable grounding connector, Protective caps

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage safety practices. Inspect all parts for damage, verify ratings, and ensure compatibility with mating parts. Check the package contents for completeness and ensure all required tools are at hand, maintaining cleanliness throughout the procedure.

  2. Assemble and Clean the Cable

    Assemble the cable in its final position, allowing enough slack for elbow removal. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.

  3. Prepare the Cable

    Remove the outer jacket (if applicable) and prepare the cable as shown in the provided diagrams for your specific cable type. If using a 20MA or 21MA grounding device, 600ECS Jacket Cable Seal, UNISHIELD, or LEAD SHEATH cable, refer to the specific installation instructions supplied with those products for jacket removal, shield connection, and grounding.

  4. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. WARNING: Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is incorrect, redo the assembly.

  6. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8 inches. Crimp the compression lug according to the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping must be between 6-3/8 inches and 7-1/8 inches (162mm-181mm). If dimensions are incorrect, redo the assembly.

  7. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite End of Elbow

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to the specified torque.

  11. Install Insulating Plug (If Applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. Proceed to the voltage test directions.

  12. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to create a small loop. WARNING: Do not damage the grounding eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with your grounding device or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for your specific meter. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.