ABB - Installation Products K656I-H0250 - 15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

ABB Installation Products K656I-H0250 15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point.…

UPC: 075114139113


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656I-H0250 is a 15-25kV, 600A deadbreak separable straight joint package from the 600 Series, designed for reliable medium-voltage cable connections in industrial and utility applications. This 2-way joint package includes an integral capacitive test point for non-intrusive voltage testing without de-energizing circuits, enhancing operational safety and efficiency. The system features a fully shielded, fully submersible design with 100% peroxide-cured EPDM molded rubber components, ensuring long-term durability in harsh environments, including direct-buried installations and small vaults/manholes. For the 15kV class, the joint supports a maximum phase-to-ground operating voltage of 8.3kV and phase-to-phase voltage of 14.4kV, with a basic impulse level (BIL) of 95kV. For the 25kV class, it supports 16.2kV phase-to-ground and 28kV phase-to-phase, with a BIL of 140kV. The joint accommodates cable insulation diameters from 0.850 to 1.050 inches and conductor sizes including 2/0 AWG compacted stranded, 3/0 AWG compacted solid, or 70 mm² compacted solid, using aluminum compression lugs. The modular design allows for future system expansions or reconfigurations, with reusable components that reduce inventory and maintenance costs. The compact footprint makes it ideal for space-constrained installations, while the deadbreak feature ensures the energized end remains shielded when disengaged, improving safety during maintenance. Each kit includes an insulated bus bar, straight receptacle housing, retaining rings, cable size adapters, lugs, bolts, and washers. Optional add-ons such as cable shield grounding kits and cable jacket sealing kits are available via suffix symbols.
  • 15-25kV voltage class with 600A continuous current rating
  • Integral capacitive test point for non-intrusive voltage testing
  • Fully shielded, fully submersible, and direct-burial capable
  • Accommodates cable insulation diameters 0.850"–1.050" and conductor sizes 2/0 AWG–70 mm²
  • Modular design supports future system expansions and reusable components

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection Type
Deadbreak Separable Straight Joint
Connection Type
Compression Lug
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Material
Aluminum, EPDM/Insulation
Material
Aluminum
Poles
2-Way
Series
600 Series
Size
0.850-1.050 inch (cable insulation diameter)
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
Fully Shielded, Fully Submersible, 100 percent Peroxide cured Molded EODM Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Straight Joint
Voltage Rating
15 to 25 kV
Voltage Rating
15-25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

756LR-J0250

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold-Shrinkable Jacket Seal Included.

K656CY-H0250-S

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. Cold-Shrinkable Jacket Seal Included.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656I-M0380-SG3

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

K656I-J0260-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.
5-25kv Straight Joint 600 Amp, Dead Break with Seal. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed Stranded 250 or Compacted Solid 300

K656I-H0280-SG3

5-25kv Straight Joint 600 Amp, Dead Break with Seal. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed Stranded 250 or Compacted Solid 300
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656I-J0300-SG3

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656CY-H0280-SG3

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What is the voltage rating for this straight joint package?

The ABB K656I-H0250 straight joint package is rated for 15-25kV.

What cable insulation diameters does this joint accommodate?

This joint package accommodates cable insulation diameters ranging from 0.850 inches to 1.050 inches.

What conductor sizes are compatible with the included lug?

The included aluminum compression lug is compatible with 2/0 AWG compacted stranded, 3/0 AWG compacted solid, or 70 mm² compacted solid conductors.

Does this package include a test point?

Yes, the ABB K656I-H0250 is a straight joint package that includes a test point.

What type of connector is this ABB joint package?

This is a 600 Series Deadbreak Separable Straight Joint Package.

How to Install K656 Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of one leg of K656CY, K656CH, or K656I Deadbreak Receptacles, designed for splicing and tapping solid dielectric cables rated for 600A at 15kV and 25kV.

Estimated time: 1h 30m

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), Assembly tool (650ATY or 600RRT), Rag, Approved safety solvent

Supplies needed:

Receptacle housings, Cable adapters, Center section (I, Wye, or H), Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, No. 14 AWG copper wire (for grounding), Tape (for markers and support)

  1. Prepare for Installation and Inspect Components

    DANGER: Ensure all apparatus is de-energized before starting. Inspect all receptacle components for damage, correct rating, and compatibility with mating parts. Confirm all package contents are complete and undamaged, and check threads for proper fit.

  2. Clean Cable Jacket and Position Housing

    Wipe the outer cable jacket clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely. If using an ECS grounding device, slide its tube onto the cable 38 inches. Then, slide the receptacle housing onto the cable 30 inches (76.2 cm).

  3. Prepare Cable End (Type-Specific)

    Refer to the special cable preparation supplement (Part A for Jacketed Concentric Neutral or Part B for Flat Metallic Tape Shielded) for specific instructions. This involves removing the outer jacket and semi-con shield to specified lengths, creating a tape marker, beveling the insulation, and thoroughly cleaning the insulation. Lubricate the cable and the inside of the cable adapter, then slide the adapter onto the cable until flush with the tape marker.

  4. Trim Insulation and Assemble Retaining Ring

    Remove any protruding cable insulation, cutting it even with the end of the cable adapter. Ensure the exposed conductor measures 4 3/4 to 5 inches (12.1-12.7 cm). Assemble the aluminum retaining ring over the conductor, snug it firmly against the cable adapter, and hand-tighten the socket head screw. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches (11.1-12.1 cm).

  5. Install and Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor immediately before fully inserting it into the crimp connector. Confirm bolt holes align with the mating part. Crimp the connector following the provided instructions, rotating each crimp 90 or 180 degrees. Verify the distance from the end of the connector to the holding collar is 6 3/4 to 7 inches (17.1-17.8 cm).

  6. Assemble and Torque Splice Bolts

    Assemble the washers and bolt: flat washer against the spade contact, then the Belleville washer (concave side down), followed by the hex-head bolt. Hand tighten. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not move or reposition any part after tightening.

  7. Lubricate and Position Receptacle Housing

    Apply the supplied or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod.

  8. Engage Receptacle Housing with Assembly Tool

    Attach either the 650ATY or 600RRT assembly tool. Use the tool to slowly slide the receptacle housing completely over the splice section. Once fully engaged, remove the nylon venting rod. WARNING: Do not place hands on the threaded rod or guide shaft if using the 600RRT tool.

  9. Complete Grounding

    If an ECS grounding device is used, complete its installation according to its specific instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye, and connect to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.