ABB Installation Products K656L2-M0380 600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.370 inch to…
UPC: 783786960521
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fully rated 15/25kV, 600A deadbreak 2-way L-Kit with test point for capacitive voltage testing
- Meets ANSI/IEEE Standard 386 with 95kV BIL (15kV) and 140kV BIL (25kV) impulse withstand
- Supports cable insulation diameters 1.370–1.630 inch and conductors up to 700/750 kcmil (compressed stranded) or 900 kcmil (compacted solid)
- Fully shielded, fully submersible molded rubber housing with 100% peroxide-cured EPDM construction
- Installation requires standard hand tools; de-energized state for safety and reliability
- Aluminum compression lug for reliable, low-resistance connections
- Compatible with 700/750 kcmil (compressed stranded) and 900 kcmil (compacted solid) conductors
Specifications
Amperage Rating | 600 A |
Application | Used to connect two cable ends and using the two insulating plugs as test points allows for capacitive voltage testing |
Color | Black |
Conductor Range | 700 to 750 kcmil , 900 kcmil |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | No Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak 2-Way L Kit with Test Point |
Voltage Rating | 15 to 25 kV |
Width | 20.8 in |
Width | 528.32 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656CY-L0380
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
162A4-B5240
15kV, 200 Amp, Loadbreak Elbow-Bushing Insert, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0
162A4-B5250-S
15kV, 200 Amps, Loadbreak, Elbow-Bushing Insert, with Sealing Kit, Cable Insulation Diameter .635 - .905 inches, Bi-Metal Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Solid/Compact.
162A4-B5250
15kV, 200 Amp, Loadbreak Elbow-Bushing Insert, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0
167ELR-7495-5240
15kV, 200 Amps, Loadbreak Repair Elbow Connector without Test Point. Cable Insulation Diameter .740-.950 inches (18.80-24.13mm). Bi-Metal Compression Lug. Conductor Sizse 240 - 1/0 Stranded/Compressed or 2/0 Solid/Compact or 53.49 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, and Installation Instructions.
168ELR-7495-5200
15kV 200 Amp Loadbreak Repair Elbow with Test Point. Cable Insulation Diameter 0.740-0.950 inches (18.80-24.13mm). BiMetal Compression Lug, Conductor Size #4 Stranded #3 Solid/Compressed. Includes Elbow Connector Housing, Compression Lug, Probe Wrench, Probe, Tube Lubricant, Installation Instructions and Crimp Chart. ANSI/IEEE Standard 386.
K655L3-J0330
15-25kV, 600 Amp, Deadbreak, 3-Way L-Kit without Test Point, without Seal. 29.49 inch (749.0mm). Cable Insulation Diameter 0.980 - 1.180 inches (24.9-30.0mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact.
168FLR3-B5230
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.Frequently Asked Questions
What is the voltage rating of the K656L2-M0380?
The K656L2-M0380 has a voltage rating of 15/25 kV, suitable for medium-voltage applications.
What conductor sizes does this kit support?
The kit supports compressed stranded conductors from 700/750 kcmil and compacted solid conductors up to 900 kcmil.
What is the cable insulation diameter range?
The K656L2-M0380 accommodates cable insulation diameters from 1.370 inch to 1.630 inch.
Does this kit include a test point?
Yes, the K656L2-M0380 includes a built-in test point for safe diagnostic access.
What material is the compression lug made of?
The compression lug is made of aluminum, providing lightweight durability and corrosion resistance.
Is the K656L2-M0380 suitable for outdoor installations?
The kit is designed for both indoor and outdoor installations, ensuring reliable performance in demanding environments.
How to Install the 600/900 Series Deadbreak Connecting Plug
This guide provides step-by-step instructions for installing the 600/900 series deadbreak connecting plug. Installation must only be performed by competent personnel trained in high voltage electrical equipment safety practices. All apparatus must be de-energized during installation or removal to prevent serious or fatal injury.
Estimated time: 30m
Tools needed:
3/8 inch hex bit socket, Torque wrench, 600ATM
Supplies needed:
Connecting Plug, Lubricant (DO NOT SUBSTITUTE), No. 14 AWG (2.5mm) copper wire or equivalent
- Prepare for Installation and Ensure Safety
Before starting, ensure all apparatus is de-energized. Do not touch or move energized products in the work area. Inspect the connecting plug and its mating parts for damage, proper rating, and compatibility. If the product came with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Install the Stud
If the mating plug device (such as an elbow, bushing extender, vault stretcher, or elbow end module) is not equipped with a stud, hand tighten the stud into the mating plug device. Ensure the stud is threaded in until the start of the flats are below the contact surface.
- Clean and Lubricate Components
Clean both the connecting plug and its mating part as indicated in the diagram. Lubricate the connecting plug, the stud, and the mating part (elbow, bushing extender, vault stretcher, or elbow end module) with the lubricant supplied. DO NOT SUBSTITUTE this lubricant, as other lubricants may be harmful to the products. Be sure to keep all surfaces clean during this process.
- Connect and Torque the Plug
Push the connecting plug into the mating part (elbow, bushing extender, vault stretcher, or elbow end module) and engage the threads. Hold the contact of the connecting plug firmly against the contact surface of the mating part. Using a 600ATM or a 3/8 inch hex bit socket and a torque wrench, tighten the connection exerting 50 to 60 foot-pounds (68 to 81 newton-meters) of torque.
- Ground the Connecting Plug (If Applicable)
If applicable, insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the connecting plug. Twist the wire tightly, taking care not to damage the eye. Connect the other end of the wire to a suitable ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.