Authorized ABB Distributor (Installation Products)
ABB - Installation Products 776LR-P2380-SG3 - 900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

ABB Installation Products 776LR-P2380-SG3 900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786457816


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 776LR-P2380-SG3 is a 900 Amp, 35kV 600 Series deadbreak elbow connector designed for medium-voltage power distribution systems. This connector features a built-in test point for safe electrical testing without de-energizing the system, enhancing operational efficiency. The fully shielded, submersible molded rubber housing ensures reliable performance in demanding environments and meets ANSI/IEEE Standard 386 requirements. Key specifications include a maximum phase-to-ground operating voltage of 21.1kV and a phase-to-phase voltage of 36.6kV, with a 150kV BIL impulse withstand rating. The connector supports conductor sizes ranging from 700/750 AWG (compressed stranded) to 900 kcmil (compacted solid) and is compatible with cable insulation diameters from 1.725 inches to 1.935 inches. The cold shrinkable seal, integrated copper braid, and constant force spring provide a moisture-resistant, high-conductivity connection. A copper compression lug ensures secure termination. The kit includes an insulated plug and cap for protection and a cable adapter for broad compatibility. Installation is designed for ease using standard hand tools in a de-energized state. This elbow connector is compatible with other Elastimold® products, including the 775CP, 775BIP, and 775ETP series, offering a versatile solution for utility, industrial, and commercial power distribution applications.
  • 900 Amp, 35kV rating for medium-voltage applications
  • Built-in test point for safe, efficient electrical testing
  • Fully shielded, submersible molded rubber housing
  • Accommodates cable insulation diameters from 1.725" to 1.935"
  • Includes cold shrinkable seal, copper braid, constant force spring, and copper compression lug
  • Copper compression lug for secure conductor termination
  • Accommodates conductor sizes 700/750 AWG to 900 kcmil

Specifications

Amperage Rating
900 A
Application
35 kV, 900 Amps
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Connection Type
Cold Shrinkable Seal, Compression Lug
Current Rating
900 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Copper, Polymer
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 1.725 inch to 1.935 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
9.0000 L
Package Weight (Metric)
4.0820 kg
600 Amp, 35KV, Direct Test Elbow, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

755DLR-N0380

600 Amp, 35KV, Direct Test Elbow, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.

756LR-N0350

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 600.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.

776LR-P5410-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

775LR-J2230

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold-Shrinkable Jacket Seal Included.

756LR-Q0400-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold-Shrinkable Jacket Seal Included.

756LR-P0400-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold-Shrinkable Jacket Seal Included.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

776LR-N2330

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

775LR-J2240

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

Frequently Asked Questions

What is the operating voltage of this elbow connector?

The ABB 776LR-P2380-SG3 is rated for 35kV medium-voltage applications.

What cable insulation diameters does this elbow support?

The elbow accommodates cable insulation diameters from 1.725 inch to 1.935 inch.

What conductor sizes are compatible with this elbow?

The connector supports conductor sizes from 700/750 AWG (compressed stranded) to 900 kcmil (compacted solid).

Does this elbow include a test point?

Yes, the ABB 776LR-P2380-SG3 features a built-in test point for safe electrical testing.

What components are included with this elbow connector?

The kit includes an insulated plug, cap, stud, lug, cable adapter, cold shrinkable seal, copper braid, and constant force spring.

How to Install 755/775LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and connection of 755LR (600-ampere) or 775LR (900-ampere) deadbreak elbow connectors on 35kV class systems, ensuring fully shielded and submersible cable connections.

Tools needed:

Cable cutting/stripping tools, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device for capacitive test points

Supplies needed:

Lubricant, Threaded stud, Grounding wire (No. 14 AWG Copper minimum), Suitable grounding connector, Insulating plug (if used), Waterproofing material for cable jacket

  1. Perform Initial Safety Checks and Cable Preparation

    DANGER: Ensure all apparatus are de-energized before beginning installation. This product must be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all package contents and components for damage, proper rating, and compatibility with mating parts. Position the cable in its final assembled position with enough slack. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the center line of the mating product. Clean the outer jacket for 24” (610mm).

  2. Prepare Cable Insulation and Install Adapter

    Prepare the cable by removing the outer jacket (if applicable) and exposing the cable insulation and semi-con shield to the specified lengths as detailed in the cable preparation diagrams. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the tape marker. Remove protruding cable insulation, cutting it even with the adapter, ensuring exposed conductor length is 4-3/8” to 4-3/4” (111mm-121mm).

  3. Crimp Compression Lug and Install Elbow

    For copper, fully insert conductor into compression lug. For aluminum, wire brush and immediately insert. Measure 'Check Dimension' before crimping (< 7” (178mm)). Crimp the lug per instructions. Wipe excess inhibitor. After crimping, distance from lug end to cable adapter should be 6-7/8” to 7-5/8” (175mm-194mm). Lubricate cable adapter and inside of elbow cable entrance. Install elbow onto cable adapter until it cannot advance further, ensuring adapter is flush with tape marker. Remove tape marker.

  4. Connect Mating Products

    WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from the elbow and mating part. Hand tighten the threaded stud (if needed) into the mating part. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. Clean and lubricate the mating part for the opposite end, insert into the elbow, hand tighten, and torque according to its specific instructions.

  5. Ground and Perform Voltage Test

    If an insulating plug is used, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow until it snaps into place. Insert a wire (at least No. 14 AWG Copper) through the grounding eye, twist to form a small loop, and connect to ground using a suitable connector. Ensure the cable shield is grounded. Waterproof the cable jacket. To voltage test, remove the test point cap with a hotstick. WARNING: Use a suitable sensing device for capacitive test points; do not use conventional equipment. Treat as energized until 'no voltage' is confirmed by other means. Clean, lubricate, and replace cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.