ABB Installation Products K655L3-J0330 15-25kV, 600 Amp, Deadbreak, 3-Way L-Kit without Test Point, without Seal. 29.49 inch…
UPC: 075114341295
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 15-25kV, 600 Amp medium-voltage applications
- Supports cable insulation diameters: 0.980 - 1.180 inches (24.9-30.0mm)
- Compatible with conductor sizes: 330-500 kcmil stranded/compressed or 600 kcmil solid/compact
- Includes aluminum compression lugs for secure terminations
- Deadbreak design eliminates need for live-line maintenance
Specifications
Amperage Rating | 600 A |
Application | Used to split one line into two on in, out, tap and using the two insulating plugs as test points allows for capacitive voltage testing |
Color | Black |
Conductor Range | 500 kcmil , 600 kcmil |
Connection | Compression |
Connection Type | Deadbreak |
Current Rating | 600 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 10.87 in |
Length | 276.098 mm |
Material | Aluminum Compression Lug |
Material | Housing - EPDM-Rubber |
Poles | 3-Way |
Size | 29.49 inch (749.0mm), Cable Insulation Diameter 0.980-1.180 inches (24.9-30.0mm) |
Special Features | No Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak 3-Way L Kit |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15-25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-J0330
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
168FLR3-B5230
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.
656ETP-N-AC04-DRG
15kV, 600 Amp, Elbow Tap Plug, Test and Ground Connector Kit with Test Point. Includes Insulated Cap, Test and Ground Reducing Tap Plug, 600 Series Elbow Housing, Cable Adapter and Tin-Plated Aluminum ShearBolt Lug. Cable Insulation Diameter N - 1.515 to 1.780 inch. Conductor Size AC04 - 750 to 1250 kcmil Stranded/Compressed/Solid/Compact.
168AFLR1-B5220
8.3kV, 200 Amp, Loadbreak Fused Elbow Connector with Two Direct Test Points. No Sealing Kit. Small Housing - 8-7/8 inches wide x 16-7/6 inches long. Cable Insulation Diameter - 0.635-0.905 inches. Bi-Metal Connector. #2 Stranded/Compressed or #1 Solid/Compact conductor size.
168FLR1C5200-S
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Crimp Connector, Conductor size #4 Stranded/Compressed or #3 Solid/Compact. S - Cold-Shrinkable Jacket Seal.
168AFLR1-A5210
8.3kV, Fuse Housing Elbow with Two Direct Test Ports, Small Housing, Cable Insulation Diameter A - 0.575 - 0.740 inch (15-19mm). Bi-Metal Compression Connector. Conductor Size 210 - #2 Solid/Compact.
168FLR1B5250-S
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact. With Jacket Seal
K655L4-F0270
15-25kV, 600 Amp, Deadbreak, 4-Way L-Kit without Test Point, without Seal. 38.18 inch (969.8mm). Cable Insulation Diameter 1.370 - 1.630 inches. Aluminum Compression Lug. Conductor Size 270 - 4/0 kcmil Stranded/Compressed or 270 kcmil Solid/Compact.Frequently Asked Questions
What voltage range does the K655L3-J0330 support?
The K655L3-J0330 is rated for 15-25kV medium-voltage applications.
What is the maximum current rating of this kit?
The kit supports a maximum current rating of 600 Amps.
What cable insulation diameters are compatible?
The kit accommodates cable insulation diameters from 0.980 to 1.180 inches (24.9-30.0mm).
What conductor sizes does this kit support?
It supports conductor sizes from 330 to 500 kcmil stranded/compressed or 600 kcmil solid/compact.
Does this kit include a test point?
No, this kit is designed without a test point.
What is the length of the K655L3-J0330 kit?
The kit measures 29.49 inches (749.0mm) in length.
What material are the lugs made of?
The kit includes aluminum compression lugs.
Is this kit suitable for live-line maintenance?
No, it is a deadbreak kit, meaning it is designed for insulated separable connections without live-line work.
How to Install the 600/900 Series Deadbreak Connecting Plug
This guide provides essential instructions for the safe installation and connection of the 600/900 Series Deadbreak Connecting Plug. Ensure all apparatus are de-energized before beginning any work.
Estimated time: 30m
Tools needed:
3/8 inch hex bit socket, Torque wrench, 600ATM (optional)
Supplies needed:
Lubricant (supplied, do not substitute), No. 14 AWG (2.5mm) copper wire or equivalent (for grounding)
- Prepare and Inspect Components
De-energize all apparatus during installation or removal of parts. Inspect the connecting plug and mating parts for any damage, verify their ratings, and ensure compatibility. Remove any protective shipping covers and replace them with appropriate HV insulated caps or connectors if the circuit will be submerged or energized. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.
- Install the Stud (If Required)
If the mating plug device is not equipped with a stud, hand tighten the supplied stud into the mating plug device. Thread the stud in until the start of the flats are below the contact surface.
- Clean and Lubricate Parts
Clean both the connecting plug and its mating part thoroughly. Apply the supplied lubricant to both parts as indicated in the diagrams. WARNING: Do not substitute the supplied lubricant, as other lubricants may be harmful to the products. Be sure to keep surfaces of the connecting plug and mating parts clean.
- Connect and Torque the Plug
Push the connecting plug firmly into the elbow, bushing extender, vault stretcher, or elbow end module and engage the threads. Ensure the contact of the connecting plug is held against the contact surface of the mating part. Using a torque wrench with a 3/8 inch hex bit socket or a 600ATM, tighten the connection to 50 to 60 foot-pounds (68 to 81 newton-meters) of torque.
- Install Additional Components (If Applicable)
If your installation requires additional elbow, bushing extender, or vault stretcher components, refer to the specific instructions packaged with those products for their installation.
- Ground the Connecting Plug (If Applicable)
If applicable, insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the connecting plug. Twist the wire tightly, taking care not to damage the eye, and connect the other end of the wire securely to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.