ABB Installation Products K655L2-M0330-S 600 Amp, 2 Way L Kit, DeadBreak, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630…
UPC: 075114245975
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp continuous current rating with 25kA symmetrical momentary rating
- Accommodates cable insulation diameters from 1.370" to 1.630"
- Compatible with 500 kcmil compressed stranded or 600 kcmil compacted solid aluminum conductors
- Fully shielded, fully submersible molded rubber housing with 100% peroxide-cured construction
- Cold-shrinkable jacket seal for environmental protection
- Aluminum compression lug for low-resistance, durable connections
- Compatible with 600 Series equipment and medium-voltage distribution systems
Specifications
Amperage Rating | 600 A |
Application | Used to connect two cable ends and using the two insulating plugs as test points allows for capacitive voltage testing |
Color | Black |
Conductor Range | 500 kcmil , 600 kcmil |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 10.87 in |
Length | 276.098 mm |
Material | Housing - EPDM-Rubber |
Special Features | Cold-Shrinkable Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak 2-Way L Kit |
Voltage Rating | 15 to 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-J0330
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
K656L3-H-5270-S
600 Amp, 15/25kV, 3-Way L-Kit, with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
K656L2-J0270
600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
K656L2-M0380
600 Amp, 15/25kV, 2-Way L-Kit, with Test Point. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
162A4-B5240
15kV, 200 Amp, Loadbreak Elbow-Bushing Insert, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0
162A4-B5250-S
15kV, 200 Amps, Loadbreak, Elbow-Bushing Insert, with Sealing Kit, Cable Insulation Diameter .635 - .905 inches, Bi-Metal Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Solid/Compact.
162A4-B5250
15kV, 200 Amp, Loadbreak Elbow-Bushing Insert, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0
2702A1-CS2037
25kV, 200 Amp, Loadbreak, Feed-Thru-Insert, Fully Rotable for 360 Degree Positioning, includes Bail Assembly to secure Feed-Thru Insert to Bushing Well. Any Customer Modification CS2037 - (4) in bag with No Instruction Sheets, Lube or Bail Plate Prepack.Frequently Asked Questions
How do I order the 2 Way L-Kit?
To order the 15/25kV, 600A 2 Way L-Kit, specify the ordering number K655L2.
What is the K655L2 kit used for?
The K655L2 kit connects two cable ends. Its insulating plugs also allow for capacitive voltage testing.
What standard does the K655L2 kit meet?
The K655L2 kit meets ANSI/IEEE Standard 386, Latest Revision.
What is the maximum operating voltage for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the continuous current rating?
The continuous current rating for both 15kV and 28kV voltage classes is 600 Amp.
What is the momentary current rating?
The momentary current rating for both 15kV and 28kV voltage classes is 25kA Sym for 10 cycles.
What is the maximum operating voltage for 28kV class?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What are the housing characteristics of the K655L2?
The K655L2 features a fully shielded, fully submersible molded rubber housing.
What materials are used in the K655L2 construction?
The K655L2 uses 100% peroxide-cured construction, including insulation and conductive EPDM materials.
How is the K655L2 connected or disconnected?
The K655L2 can be easily connected or disconnected using standard hand tools and equipment. This must be done in a de-energized state.
How to Install the 600/900 Series Deadbreak Connecting Plug
This guide provides step-by-step instructions for the safe and proper installation of the 600/900 series deadbreak connecting plug, an accessory for power distribution systems. It covers stud installation, cleaning, lubrication, connection, and grounding.
Estimated time: 30m
Tools needed:
Torque wrench, 3/8 inch hex bit socket, 600ATM (optional)
Supplies needed:
600/900 Series Deadbreak Connecting Plug, Lubricant (supplied with plug), No. 14 AWG (2.5mm) copper wire (for grounding)
- Prepare the Mating Plug Device and Stud
DANGER: Ensure all apparatus are de-energized during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. If the mating plug device is not equipped with a stud, hand tighten the stud into the mating plug device until the start of the flats are below the contact surface.
- Clean and Lubricate Components
Clean both the connecting plug and its mating part thoroughly. Lubricate both parts using only the lubricant supplied with the connecting plug. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the products. Maintain cleanliness of all surfaces during this process.
- Connect and Torque the Connecting Plug
Push the connecting plug firmly into the elbow, bushing extender, vault stretcher, or elbow end module, ensuring the threads engage. Hold the contact of the connecting plug against the contact surface of the mating part. Using a 600ATM or a 3/8 inch hex bit socket with a torque wrench, tighten the connection to 50 to 60 foot-pounds (68 to 81 newton-meters) of torque.
- Ground the Connecting Plug (If Applicable)
If applicable, insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the connecting plug. Twist the wire tightly, taking care not to damage the eye. Connect the other end of the wire securely to ground.
- Install Additional System Components (Optional)
If your system requires additional components such as an elbow, bushing extender, or vault stretcher, continue their installation by following the instructions packaged with those specific products.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.