ABB - Installation Products K655L1 - 15/25kV 600 Series Deadbreak 1-Way L-Kit. Includes 600 Amp Basic Elbow, 28 kV 600 Amp Stud, Two Insulated Plugs with Caps, Compound and Instructions

ABB Installation Products K655L1 15/25kV 600 Series Deadbreak 1-Way L-Kit. Includes 600 Amp Basic Elbow, 28 kV 600 Amp…

UPC: 783786424740


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655L1 is a 15/25kV 600 Series Deadbreak 1-Way L-Kit designed for medium-voltage cable terminations. This kit includes a 600 Amp Basic Elbow, a 28 kV 600 Amp Stud, two insulated plugs with caps, compound, and installation instructions. The 600 Amp Basic Elbow is rated for deadbreak applications, allowing safe connection and disconnection under load without interrupting service. The 28 kV 600 Amp Stud provides a high-current termination point for medium-voltage cables, ensuring reliable electrical contact. The included insulated plugs and caps protect unused terminations from contamination and accidental contact, maintaining system integrity. The compound is formulated for environmental sealing, preventing moisture ingress and dielectric breakdown. This kit is part of ABB’s 600 Series, a trusted line of medium-voltage accessories known for durability and compliance with industry standards. Typical applications include utility substations, industrial power distribution, and commercial electrical systems where medium-voltage cable terminations are required. The components are designed for compatibility with ABB’s 600 Series connectors and adhere to applicable ANSI/IEEE and IEC standards for medium-voltage deadbreak systems.
  • Includes 600 Amp Basic Elbow for deadbreak applications
  • 28 kV 600 Amp Stud for high-current terminations
  • Two insulated plugs with caps for unused termination protection
  • Environmental sealing compound for moisture resistance
  • Comprehensive installation instructions included

Specifications

Amperage Rating
600 A
Application
The K655L1 elbow kit is comprised of a K655LR elbow connector and two K650BIP basic insulating plugs. It is used to dead-end cable and using the two insulating plugs as test points allows for capacitive voltage testing
Color
Black
Color
Blue
Connection Type
Deadbreak
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
10.87 in
Length
276.098 mm
Material
Poly
Material
EPDM-Rubber
Series
600 Series
Special Features
Fully rated 15/25kV, 600 Amp Deadbreak 1 Way L-Kit. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak 1-Way L-Kit
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Solenoid Valve Connectors, Field Wireable, 3 Pole, Form A 18mm, 250V, 10A, PG9 opening

VAN-029-00

Solenoid Valve Connectors, Field Wireable, 3 Pole, Form A 18mm, 250V, 10A, PG9 opening
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

168RLR-H-270

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, 35kV, 600 Series Deadbreak 2-Way L-Kit. Does not include cable adapters or compression lugs, must be ordered separately.

755L2

600 Amp, 35kV, 600 Series Deadbreak 2-Way L-Kit. Does not include cable adapters or compression lugs, must be ordered separately.
15kV 600 Series Test and Ground and Stick-Op, Connector System, Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op. 600 to 200 Amps.

650LRTPA3

15kV 600 Series Test and Ground and Stick-Op, Connector System, Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op. 600 to 200 Amps.
35kV 600 Series Deadbreak Stick-Op Loadbreak Reducing Tap Plug. 600 to 200 Amps.

750LRTPA2

35kV 600 Series Deadbreak Stick-Op Loadbreak Reducing Tap Plug. 600 to 200 Amps.
35kV 600 Series Deadbreak Cam-Op Loadbreak Reducing Tap Plugs (Visi-Break)

750LK-C-VB

35kV 600 Series Deadbreak Cam-Op Loadbreak Reducing Tap Plugs (Visi-Break)
15 kV, 600 Amp, Deadbreak Cam-Op Reducing Tap Plugs (Visi-Break)

650LK-C-VB

15 kV, 600 Amp, Deadbreak Cam-Op Reducing Tap Plugs (Visi-Break)
15kV, 600 Amp, Deadbreak Cam-Op Link Bracket Assembly. 304 Stainless Steel Lever Arm is 13 inches long.

650LK-C

15kV, 600 Amp, Deadbreak Cam-Op Link Bracket Assembly. 304 Stainless Steel Lever Arm is 13 inches long.

Frequently Asked Questions

What is the K655L1 product?

The K655L1 is a 15/25kV 600 Amp Deadbreak 1 Way L-Kit, used for dead-ending cable.

How is the K655L1 connected or disconnected?

The K655L1 can be easily connected or disconnected using standard hand tools and equipment, but only in a de-energized state.

What are the housing features of the K655L1?

The K655L1 features a fully shielded, fully submersible molded rubber housing.

What materials are used in the K655L1's construction?

The K655L1 has 100% peroxide-cured construction, including insulation and conductive EPDM materials.

What is the AC one minute withstand for 15kV class?

For the 15kV voltage class, the AC one minute withstand is 34kV. The DC 15 minutes withstand is 53kV.

What is the AC one minute withstand for 28kV class?

For the 28kV voltage class, the AC one minute withstand is 45kV. The DC 15 minutes withstand is 84kV.

What is the max operating voltage for 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and phase-to-phase is 28kV.

What is the BIL impulse withstand rating for 28kV class?

For the 28kV voltage class, the BIL impulse withstand rating is 140kV (1.2 x 50 microsecond wave).

What is the BIL impulse withstand rating for 15kV class?

For the 15kV voltage class, the BIL impulse withstand rating is 95kV (1.2 x 50 microsecond wave).

What is the max operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and phase-to-phase is 14.4kV.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 655/675LR and K655/K675LR deadbreak elbow connectors, including cable preparation, component assembly, and voltage testing for 15kV and 25kV class systems.

Estimated time: 2h

Tools needed:

Wire brush, Crimping tool, Hotstick, Suitable voltage sensing device, Torque wrench

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug, Lubricant, Threaded stud, Tape marker, No. 14 AWG Copper wire (or equivalent), Suitable grounding connector, Protective caps (if applicable), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Position and Cut Cable

    Assemble the cable in its final position, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. DANGER: All apparatus must be de-energized during installation or removal of parts.

  2. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent-back concentric neutral wires.

  3. Prepare Cable Insulation and Shield

    Prepare the cable according to its type (e.g., non-jacketed, jacketed, Unishield, lead sheath). Remove the outer jacket (if applicable) and prepare the cable insulation and semi-con shield to the specified dimensions (9-3/4”, 10-3/4”, 12-3/4” from the tape marker). If using a 20MA/21MA grounding device or 600ECS Jacket Cable Seal, refer to their specific installation instructions for cable outer jacket removal, shield connection, and grounding.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor must be between 4-1/4” and 4-9/16” (108mm-116mm). If the length is outside this range, redo the assembly.

  6. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the 'Check Dimension' before crimping (it should be less than 6-3/8”). Crimp the compression lug following its supplied instructions. Wipe all excess inhibitor from the lug and cable adapter surface. After crimping, verify the distance from the end of the lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm); if not, redo the assembly.

  7. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if it is not already equipped. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect Elbow to First Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite Mating Part

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  11. Install Insulating Plug (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place.

  12. Ground the Cable Shield

    Insert one end of a wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow the instructions supplied with the grounding device, or use an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  13. Verify Torque for L-Kits

    CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to the specified torque per its provided instructions.

  14. Remove Voltage Test Point Cap

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Remove the test point cap with a hotstick. When removing, peel off at an angle rather than pulling directly in line with the test point assembly.

  15. Perform Voltage Test

    WARNING: Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means.

  16. Replace Voltage Test Point Cap

    After voltage detection has been made, clean and lubricate the inside surface of the cap with silicone lubricant and replace it securely on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.