ABB - Installation Products 750LRTPA2 - 35kV 600 Series Deadbreak Stick-Op Loadbreak Reducing Tap Plug. 600 to 200 Amps.
ABB - Installation Products

750LRTPA2

UPC: 783786470440


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 750LRTPA2 is a 35kV 600 Series Deadbreak Stick-Op Loadbreak Reducing Tap Plug designed for safe and efficient loadbreak operations in medium-voltage applications. This device transitions between 600A and 200A systems, enabling reliable load management and maintenance without full system shutdown. The deadbreak design ensures arc-free disconnection, reducing risk during hotstick operations. Compatible with standard 600A class equipment, it integrates seamlessly into existing 35kV distribution networks. Key applications include utility substations, industrial power systems, and renewable energy integration where load switching and fault isolation are critical. The reducing tap configuration allows for step-down connections while maintaining full-rated insulation integrity. With ABB’s proven reliability in medium-voltage systems, this plug meets ANSI C119.4 and IEEE 386 standards for deadbreak connectors. Ideal for utilities and contractors requiring durable, field-proven solutions for loadbreak operations.
  • 35kV rated deadbreak plug for safe loadbreak operations
  • Transitions between 600A and 200A systems
  • Deadbreak design eliminates arc during disconnection
  • Compliant with ANSI C119.4 and IEEE 386 standards
  • Field-proven reliability for utility and industrial applications

Specifications

Amperage Rating
600 to 200 A
Color
Black
Connection Type
Deadbreak
Current Rating
600 to 200 A
Insulation
EPDM Rubber
Material
EPDM-Rubber
Mounting Type
Stick-Op
Series
600 Series
Size
600 Series
Standard
ANSI/IEEE Standard 386
Type
Stick-Op Loadbreak Reducing Tap Plug
Voltage Rating
35kV
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.2500 L
Package Weight (Metric)
1.0210 kg
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
35kV 600 Series Deadbreak Cam-Op Loadbreak Reducing Tap Plugs (Visi-Break)

750LK-C-VB

35kV 600 Series Deadbreak Cam-Op Loadbreak Reducing Tap Plugs (Visi-Break)
15 kV, 600 Amp, Deadbreak Cam-Op Reducing Tap Plugs (Visi-Break)

650LK-C-VB

15 kV, 600 Amp, Deadbreak Cam-Op Reducing Tap Plugs (Visi-Break)
15kV, 600 Amp, Deadbreak Cam-Op Link Bracket Assembly. 304 Stainless Steel Lever Arm is 13 inches long.

650LK-C

15kV, 600 Amp, Deadbreak Cam-Op Link Bracket Assembly. 304 Stainless Steel Lever Arm is 13 inches long.
15-25kV 600 Series Deadbreak 3-Way Insulated Bus Bar with Test Point

K656CY-BUS

15-25kV 600 Series Deadbreak 3-Way Insulated Bus Bar with Test Point
15-25kV 600 Series Deadbreak 2-Way Insulated Bus Bar with Test Point.

K656I-BUS

15-25kV 600 Series Deadbreak 2-Way Insulated Bus Bar with Test Point.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle Housing Only

K655YBSR

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle Housing Only

Frequently Asked Questions

What voltage rating does this plug support?

The plug is rated for 35kV medium-voltage applications.

What is the current rating range?

The device supports 600A primary and 200A secondary current ratings.

Is this plug compatible with hotstick operations?

Yes, it is designed for deadbreak stick-op loadbreak operations.

What standards does this plug meet?

It complies with ANSI C119.4 and IEEE 386 deadbreak connector standards.

Can this plug be used in renewable energy systems?

Yes, it is suitable for medium-voltage systems including renewable energy integration.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides detailed instructions for installing the LINK-C 600 amp deadbreak cam link operable connector system. It covers mounting, wiring, and grounding procedures. Always ensure all apparatus are de-energized before beginning any installation or removal.

Estimated time: 1h 30m

Tools needed:

Torque wrench, Suitable tool for 1 inch hex (e.g., hex socket or wrench), Hot stick, Welding equipment (if studs are not pre-welded)

Supplies needed:

ELASTIMOLD supplied lubricant, 3/8-16 x 2 inch studs (if required for mounting), 3/8-16 hex nuts (6 required for mounting), 3/8-16 lockwashers (3 required for mounting), Spacers (optional, for stand-off plug support), #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector

  1. Perform Initial Safety Checks and Preparation

    DANGER: Ensure all apparatus are de-energized during installation or removal of parts. This product should only be installed by competent personnel trained in high voltage electrical equipment safety. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and/or mating products. Have all required tools and maintain cleanliness throughout the procedure.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the specific installation instructions supplied with the elbow. Ensure it is positioned to align correctly with the stand-off plug or apparatus bushing.

  3. Install the Mounted Stand-Off Plug (If Applicable)

    If using a mounted stand-off plug, weld three 3/8-16 x 2 inch studs to the faceplate according to customer standard practice and specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Place the stand-off plug over the studs, resting on the nuts or optional spacers. Secure with three lockwashers and three hex nuts, tightening each to 12 foot-lbs torque. Verify the top surfaces of the bushing and stand-off plug are in-line.

  4. Install Bushing Extender and Elbow onto Standoff Plug

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing using a suitable tool on the 1 inch hex portion, torquing to 50-60 ft-lbs. Clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy standoff plug. Insert the 600AMT into the retainer contact through the compression lug hole, engage the internal hex broach, and thread into the epoxy standoff plug, torquing to 50-60 ft-lbs.

  5. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until clamp tabs are flush and tight.

  6. Align and Secure the Elbow in the Bracket

    Position the elbow within the alignment bracket so that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket using the supplied hardware. Torque the clamp by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Insert and Engage the Link

    Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link to be perpendicular to the switch faceplate when inserted. Insert the Link into the bushing extender and elbow, ensuring both lever arms are inside the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick on the hot stick eye to move the lever arms downward, engaging the roller pin and moving the Link inward until the lever arms are perpendicular to the alignment bracket leg.

  8. Ground the System

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground and then install the desired mating product on the 200 amp interface according to its specific installation instructions. Ground the cable: if concentric neutral cable, twist wires and connect to ground; if 20MA or 21MA grounding devices, connect the ground lead to ground. For three-phase installations, tie all grounds from all three phases to a common ground point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.