ABB Installation Products 168RLR-H-270 15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation…
UPC: 783786659296
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV, 200 Amp loadbreak replacement elbow connector
- Accommodates cable insulation diameters from 0.850" to 1.050"
- Fully shielded, fully submersible molded rubber housing
- 95kV BIL impulse withstand, 34kV AC one-minute withstand
- Non-corrosive capacitive test point for safe voltage verification
Specifications
Amperage Rating | 200 A |
Application | Repair of a Failed Elbow Connection |
Color | Blue |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Conductor Size | AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67 |
Connection | Compression |
Connection Type | Loadbreak Replacement Elbow Connector with Test Point |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 18 in |
Length | 457.2 mm |
Material | Molded Rubber, Peroxide-Cured |
Material | Housing - EPDM-Rubber |
Material | Poly |
Series | 168RLR-H |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Size | 0.850-1.050 inch (insulation diameter) |
Special Features | Extended Length Housing and Compression Lug. Fully Shielded, Fully Submersible Molded Rubber Housing. 100 Percent Peroxide-Cured Insulation, Insert and Jacket. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Width | 7.63 in |
Width | 193.802 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.1000 L |
Package Weight (Metric) | 1.4060 kg |

162LR-D5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
756LR-M2380-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
K465LR-G-0230
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Aluminum Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Solid/Compact or 50 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
776LR-M5330-S
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
756LR-M2340-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
756LR-J0240-S
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.
776LR-N5380-S
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What is the maximum operating voltage for this connector?
The connector is rated for a maximum operating voltage of 15kV.
What cable insulation diameters does this connector support?
This connector supports cable insulation diameters from 0.850 inch to 1.050 inch.
What conductor sizes are compatible with this elbow connector?
Compatible conductor sizes include AWG compressed stranded 4/0, solid 250, and mm² 126.67.
Does this connector include a test point for voltage verification?
Yes, this connector features an integrated test point for safe voltage verification without disconnecting the cable.
Is this connector suitable for loadbreak applications?
Yes, this is a loadbreak replacement elbow connector designed for safe connection and disconnection under load.
How to Install the 168RLR Loadbreak Replacement Elbow Connector
This guide provides step-by-step instructions for the installation and initial setup of the 168RLR Loadbreak Replacement Elbow Connector, converting livefront terminations to deadfront for UD cables.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Hotstick, Wire brush, Crimping tool, Wire strippers, Capacitive voltage tester
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Wire connectors, Silicone grease
- Remove Existing Livefront Termination
Ensure all apparatus is de-energized during installation. Remove the rubber cap from the terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Remove the terminator housing from the cable.
- Prepare the Cable
Train cables to be straight and in-line with the bushing centerline. Cut the cable to 10-1/2 inches from the bushing centerline. If the insulation shield measures less than 6-1/2 inches, continue. If greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end, cutting squarely. DO NOT NICK THE CONDUCTOR.
- Install the Compression Lug
Wire brush the bare aluminum conductor and immediately install the compression lug. Rotate the lug to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Connector Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back and forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten with the probe wrench until the wrench bends.
- Connect the Concentric Neutral
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. Add the supplied hose clamp as shown and tighten snugly, but do not overtighten.
- Connect the Elbow to the Bushing Plug
LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated hotstick type live-line tool; DO NOT OPERATE BY HAND. Ensure the area is clear of obstructions. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle over the bushing plug, inserting the elbow male contact until slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock.
- Perform Voltage Test (168RLR Only)
For 168RLR models, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can cause false readings; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.