
UPC: 783786555901
Contact for Pricing
Overview
- Rated for 600 Amps and 35kV for medium-voltage applications
- 2-way deadbreak configuration for branching or extending circuits
- Part of ABB's 600 Series, designed for durability in harsh environments
- Allows connections under load (deadbreak) for operational flexibility
- Requires separate purchase of cable adapters and compression lugs
Specifications
Amperage Rating | 600 A |
Application | Used to connect two cable ends and using the two insulating plugs as test points allows for capacitive voltage testing |
Color | Black |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | No Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak 2-Way L Kit |
Voltage Rating | 35 kV |
Width | 25.38 in |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

376LR-J-5260
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
650LRTPA3
15kV 600 Series Test and Ground and Stick-Op, Connector System, Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op. 600 to 200 Amps.
650LK-C
15kV, 600 Amp, Deadbreak Cam-Op Link Bracket Assembly. 304 Stainless Steel Lever Arm is 13 inches long.Frequently Asked Questions
What is required for a 900A 2 Way L-Kit?
For a 900A kit, it is mandatory to have all components, including cable, connector, and bushing, made of copper.
What are the main applications of this kit?
The kit connects two cable ends and allows for capacitive voltage testing using the two insulating plugs as test points.
What is the maximum operating voltage?
The maximum phase-to-ground operating voltage for the 35kV class is 21.1kV.
What is the continuous current rating?
The continuous current rating for this product is 600 Amp.
What standards does this product meet?
This product meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating?
The impulse withstand rating (BIL) is 150kV (1.2 x 50 microsecond wave).
What are the key features of the housing?
The kit features a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured construction.
How is the kit connected or disconnected?
It can be easily connected or disconnected using standard hand tools and equipment when in a de-energized state.
What components are included in the kit?
The kit includes two elbow connectors, two basic insulating plugs, two cable adapters, two compression lugs, and one connecting plug.
Are there optional accessories available?
Yes, optional accessories allow for visible external separation, by-pass, isolation, dead-ending, grounding, and testing.
How to Install 755/775LR Deadbreak Elbow Connectors
Install 755/775LR Deadbreak Elbow Connectors to provide fully shielded, submersible deadfront cable connections for 600-ampere or 900-ampere, 35kV class systems.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Wire brush, Hotstick, Voltage sensing device (for capacitive test points), Wire strippers, Screwdriver, Torque wrench
Supplies needed:
755/775LR Deadbreak Elbow Connector Kit, Lubricant (silicone type), No. 14 AWG Copper wire (or equivalent) for grounding, Grounding connector, Tape marker, HV insulated caps (if not connecting to another part), Grounding device (if applicable), Vinyl tape (if applicable for cable shield), Waterproofing material (for cable jacket)
- De-energize and Position Cable
DANGER: Ensure all apparatus is de-energized before beginning installation. Position the cable in its final assembled location, allowing enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.
- Clean and Prepare Cable
Clean the outer jacket of the cable for a distance of 24 inches (610mm). Prepare the cable according to its type (e.g., Unishield, Lead Sheath, Jacketed, or Non-Jacketed) and the provided diagrams, removing the outer jacket and semi-con shield as required. Refer to specific instructions for grounding devices or shield adapters if used.
- Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare Conductor and Crimp Lug
Remove protruding cable insulation, cutting it even with the cable adapter end without nicking the adapter or conductor. Verify the exposed conductor length is 4-3/8 to 4-3/4 inches (111-121mm). For copper, fully insert the conductor into the compression lug. For aluminum, wire brush the conductor and immediately insert it. Measure the 'Check Dimension' (must be less than 7 inches/178mm) before crimping. Crimp the lug per its instructions, then wipe off excess inhibitor. Verify the lug-to-adapter distance is 6-7/8 to 7-5/8 inches (175-194mm).
- Install Elbow onto Cable Adapter
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect Elbow to Mating Part
WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from the elbow and mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud.
- Complete Mating Connections (if applicable)
If connecting to another mating part, clean and lubricate its surface. Insert the mating part into the elbow, engage threads, and hand tighten. CAUTION: For 600-amp L-Kits, torque each component to the specified value per plug connector instructions. If using an insulating plug, clean and lubricate its voltage detection cap's inner surface, then push it onto the elbow until it snaps into place.
- Ground the Cable Shield
Insert one end of a No. 14 AWG Copper wire (or equivalent) through the grounding eye, twisting to form a small loop without damaging the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions for a grounding device or use an alternate method. Waterproof the cable jacket to prevent moisture ingress.
- Perform Voltage Test
Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the cap's inner surface with silicone lubricant and replace it.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.



