ABB Installation Products K655DLR-H0240 15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and…
UPC: 075114194938
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV Deadbreak connector for medium voltage applications
- 600 Series direct test elbow with insulated plug and cap
- Accommodates cable insulation diameters from 0.850" to 1.050"
- Includes stud, lug, and cable adapter for complete termination
- Aluminum compression lug for 1/0 AWG stranded or 2/0 AWG solid conductors
Specifications
Amperage Rating | 600 A |
Application | 15/25kV, 600 Amps |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Compression |
Environmental Conditions | All Weather Conditions, Fully Submersible |
Insulation | True |
Length | 13 in |
Length | 330.2 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators. Direct conductor test point equipped elbow |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Direct Test Elbow Connector |
Voltage Rating | 15 to 25 kV |
Width | 10.36 in |
Width | 263.144 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

252LR-B5240
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
K655DLR-J0330
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation .980-1.180 inches, Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact
K655DLR-G0270
15/25kV, 600 Amp, Elbow with Direct Test and Sealing Kit. Cable Insulation Diameter - .760-.950 inch, Aluminum Lug, Conductor Size 270 - 4/0 Stranded/Compressed or 250 Compact/Solid.
K655DLR-G0280
15/25kV, 600 Amp, Elbow with Direct Test and Sealing Kit. Cable Insulation Diameter - .760-.950 inch, Aluminum Lug, Conductor Size 280 - 250 Stranded/Compressed or 300 Compact/Solid.
K655DLR-L0330
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact
K655SR-L0230
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size 230 - #1 Compressed-Stranded or 1/0 Compacted Solid.
K655SR-K0330-SG3
25KV Straight Receptacle 600 Amps with Cable Adapter, Lug Retainer Ring and Sealing Kit. Cable Insulation Diameter 1.090-1.310 inches, Aluminum Lug, Conductor Size 500-600 kcmil. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
K655DLR-K0300
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 350 Stranded/Compressed or 400 Solid/CompactFrequently Asked Questions
What is the voltage rating of the ABB K655DLR-H0240?
The ABB K655DLR-H0240 is rated for 15/25kV applications.
What is the cable insulation diameter range for this elbow?
This deadbreak elbow is designed for cable insulation diameters between 0.850 inches and 1.050 inches.
What type of lug is included with the K655DLR-H0240?
The K655DLR-H0240 comes with an aluminum compression lug.
What conductor sizes can be used with this deadbreak elbow?
It is suitable for 1/0 AWG compressed stranded or 2/0 AWG compacted solid conductors.
How to Install K655/K675DLR Direct Test Elbow Connectors
This guide provides step-by-step instructions for the safe installation and wiring of K655/K675DLR Direct Test Elbow Connectors, including cable preparation, lug crimping, and connection to mating apparatus for 15kV and 25kV class systems.
Estimated time: 2h
Tools needed:
Wire strippers, Measuring tape or ruler, Wire brush (for aluminum conductors), Crimping tool (for compression lugs), Hotstick tool (for direct test port cap operations), Torque wrench (for mating parts), Suitable connector tool (for grounding wire)
Supplies needed:
K655/K675DLR Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack, Ground wire (min. No. 14 AWG copper), Suitable ground connector, Vinyl plastic tape (if using flat metallic tape shield), Tape retainer (if using fabric tape shield), Tape marker (for various shield types), HV insulated cap(s) or connector(s) (to replace shipping covers), Waterproofing material (for cable jacket)
- De-energize Apparatus and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Ensure all components are complete, undamaged, and compatible with the cable and mating products. Read all instructions thoroughly before beginning.
- Position and Cut Cable
Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.
- Clean Cable Outer Surface
Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.
- Prepare Cable Jacket and Shield
Remove the outer jacket and prepare the cable shield according to the specific type (e.g., fold back shield wires, remove flat metallic tape, remove fabric tape, remove longitudinally corrugated shield, or remove semi-con shield) to the dimensions specified in the product documentation. If using UNISHIELD or lead sheath cable, refer to the 10TL cable shield adapter instructions. Do not cut or nick the cable insulation.
- Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Expose and Measure Conductor
Remove the protruding cable insulation, cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches (111mm) and 4-11/16 inches (119mm). If not, redo the assembly.
- Crimp Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' (must be less than 6-1/2 inches / 165mm). Crimp the compression lug following the supplied instructions. Wipe off all excess inhibitor. The distance from the end of the lug to the cable adapter after crimping should be 6-1/2 to 7-1/4 inches (165mm-184mm). If not, redo the assembly.
- Install Elbow
Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. Reposition the cable adapter if necessary, then remove the tape marker.
- Prepare Mating Products for Connection
DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (if supplied with elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.
- Connect Elbow to Mating Part
Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.
- Connect Opposite Mating Part (if applicable)
Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions. CAUTION: When constructing 600amp L-Kits, tighten each component to specified torque.
- Install Insulating Plug and Voltage Detection Cap (if applicable)
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place.
- Ground Cable Shield and Waterproof Jacket
Insert one end of a No. 14 AWG copper wire (or equivalent ampacity) through the grounding eye, twist to form a small loop, and connect to ground using a suitable connector. The cable shield must be grounded. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Observe Direct Test Port Safety
DANGER: The direct test port provides direct access to the cable conductor. Insertion of any object other than the appropriate direct voltage test port adapter and meter, or being in close proximity to it, can result in electric shock, serious injury, or death. Always follow separate operating instructions for test port adapters and meters.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.