ABB Installation Products K650ETPS 600 Amp, 25kV, 600 Series Loadbreak Elbow Tap Plug, use 600ATM assembly tool. Includes…
UPC: 783786626496
Contact for Pricing
Call (262) 252-1600 or email [email protected] for pricing and availability.
Overview
- 25kV voltage class with 15.2kV phase-to-ground operating voltage
- 200A loadbreak interface rated for continuous and loadbreak operation
- 600A deadbreak interface with 25kA symmetrical momentary rating
- Meets ANSI/IEEE Standard 386 for medium-voltage applications
- Includes 28kV 600A stud and requires 600ATM assembly tool
Specifications
Application | 25 kV, 600 Amps |
Current Rating | 600 A |
Series | 600 Series |
Size | 600 Series |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Elbow Tap Plug |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.0000 L |
Package Weight (Metric) | 0.9070 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
K650BIPSP
15/25kV 600 Series Deadbreak Insulated Plug (with Cap), Factory assembled stud which is not field removable.Frequently Asked Questions
How can I order the K650ETP with a loose stud?
To order the K650ETP with a loose stud, add the suffix "S" to the part number.
What is the K650ETP elbow tap plug used for?
The K650ETP permits a 200 Amp tap off of a mating 600 Amp connector.
What tool is required to install the K650ETP?
The K650ETP is installed using a 600ATM assembly tool.
What products are compatible with the K650ETP?
The K650ETP mates with products like 273DR, 273DRG, 273ESA-XX, 275LR, 275LRJS, 273ELR, 273RLR, 273DLR, 273DELR, and 370GLR.
Which industry standard does the K650ETP meet?
The K650ETP meets ANSI/IEEE Standard 386, Latest Revision.
What are the operating voltage ratings for the K650ETP?
It has a 15.2kV maximum phase-to-ground operating voltage and 26.3kV maximum phase-to-phase.
What is the impulse withstand rating of the K650ETP?
The K650ETP has a 125kV BIL impulse withstand rating.
What are the current ratings for the 200A loadbreak interface?
The loadbreak interface is rated for 200 Amp continuous and loadbreak, and 10kA Sym for 10 Cycle Momentary & Fault Close.
What are the current ratings for the 600A deadbreak interface?
The deadbreak interface is rated for 600 Amp continuous and 25kA Sym for 10 Cycle Momentary.
What type of insulation does the K650ETP use?
The K650ETP features peroxide-cured insulation and jacket.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides detailed instructions for the safe and proper installation of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and connection procedures.
Estimated time: 2h
Tools needed:
Hot stick, Suitable tool for 1 inch hex (e.g., socket wrench), Torque wrench, Wire strippers, Welding equipment (if using welded studs), 600ATM (Operating Tool), 600AMT (Operating Tool)
Supplies needed:
ELASTIMOLD supplied lubricant, 600 amp elbow, Stand-off plug (if applicable), 3/8-16 x 2” studs (if using welded studs), Hex nuts (3/8-16), Lockwashers (3/8-16), Spacers (optional, not supplied), Bushing extender, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connectors, Mating 200 amp product (if applicable)
- De-energize Apparatus and Inspect Components
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Verify that all components are complete, undamaged, and compatible with the cable and mating products. Do not touch or move energized products.
- Install 600 Amp Elbow onto Cable
Install the 600 amp elbow onto the cable following the specific installation instructions provided with the elbow. Ensure the elbow is positioned to align correctly with the stand-off plug.
- Mount Stand-Off Plug (If Applicable)
If using a mounted stand-off plug, weld three 3/8-16 x 2” studs to the faceplate according to specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Place the stand-off plug over the studs, then secure it with three lockwashers and hex nuts, tightening each to 12 foot-lbs torque. Verify the top surfaces of the bushing and stand-off plug are in-line.
- Install Bushing Extender and Elbow
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender using ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread the retainer contact into the apparatus bushing using a suitable tool on the 1” hex portion, torquing to 50-60 ft-lbs. Similarly, clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy standoff plug, insert the 600AMT into the retainer contact, and thread it into the standoff plug, torquing to 50-60 ft-lbs.
- Install Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight.
- Position and Secure Elbow in Bracket
Position the elbow within the alignment bracket so that the elbow cuff is evenly lined up with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket using the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Install the Link Connector
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link to be perpendicular to the switch faceplate when inserted. Insert the Link into the bushing extender and elbow, ensuring both lever arms are inside the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick eye to move the lever arms downward, engaging the roller pin and moving the Link inward until the lever arms are perpendicular to the alignment bracket leg.
- Ground the System
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through its grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground and install the desired mating product onto the 200 amp interface according to its instructions. Finally, ground the cable: if using concentric neutral cable, twist the neutral wires and connect to ground; if using 20MA or 21MA grounding devices, connect their ground lead to ground. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.