ABB Installation Products K675TBC 15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type…
UPC: 783786629725
Contact for Pricing
Call (262) 252-1600 or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage rating with 900 Amp continuous current capacity
- Molded epoxy construction with stainless steel flange for corrosion resistance and secure mounting
- 13.75" length x 4.5" diameter with 8.563" shank length for cover or side-mount installations
- Meets ANSI/IEEE Standard 386 with 125kV BIL impulse withstand and 40kV AC one-minute withstand
- Includes factory-installed 5/8-11 UNC-2A stud; additional stud required for completion
Specifications
Application | In-Air Applications |
Connection Type | Deadbreak |
Current Rating | 900 A |
Material | Molded Epoxy Body and Stainless Steel Flange |
Material | Molded Epoxy with Stainless Steel Flange |
Mounting Type | Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear |
Size | Overall Length 13.75 inch, Diameter 4.50 inch |
Size | Length 13.75 inch, Diameter 4.50 inch |
Special Features | Conductive Shield made of Molded Conductive EPDM makes Positive Ground Contact with EPDM Flange of Bushing Insert. Stainless Steel Flange Resists Corrosion and can be Externally Clamped or Welded to Apparatus |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Bushing - 900 Amps |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 9.6500 L |
Package Weight (Metric) | 4.3770 kg |

10EP-FA
200 Amp, 15/25kV, Deadbreak Elbow Cable Entrance Insulating Plug, Cable Insulation Diameter 0.575 inch to 0.685 inch. 9.25 inches Long. Plastic.
K650LB
25kV 600 Series Deadbreak Insulating Plug / Stand-Off Plug, includes Silicone Lubricant and Instructions. Length 3.9.39 inch, Widest Diameter 3 inch. Epoxy.
655BEA3
15kV 600 Series Loadbreak Stick-Op Bushing Adapter, Window OP CA, 600AT assembly tool required for operation and/or installation of Stick-Op.
K1601PCC-R
15/25KV, Molded Epoxy Flange for gasketed clamp mounting only, with Replaceable Well Stud, Bushing Well
K650TBC
15/25kV, 600 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Includes Boot and Collar.
K1601-PC-S2R
15/25kv, Short Shank Well without Bail Tabs and with Replaceable Well Stud (2-3/4 inch Bushing Shank Length)
K1601-PC-S2
15/25kv, Short Shank Well without Bail Tabs and Non-Replaceable Well Stud (2-3/4 inch Bushing Shank Length), side mountFrequently Asked Questions
What is the voltage rating of the K675TBC deadbreak bushing?
The ABB K675TBC deadbreak bushing has a voltage rating of 15/25kV.
What is the continuous current rating for this bushing?
The K675TBC deadbreak bushing is rated for 900 Amps of continuous current.
What materials is the K675TBC bushing constructed from?
The bushing is constructed from molded epoxy with a stainless steel flange.
What types of equipment is this bushing designed for?
This deadbreak bushing is designed for in-air applications on pad-mounted, vault-type, or submersible transformers and switchgear.
Does the K675TBC come with all necessary studs?
The K675TBC includes one factory-installed 5/8-11 UNC-2A stud. A second stud must be purchased separately.
What are the overall dimensions of the K675TBC bushing?
The K675TBC deadbreak bushing has an overall length of 13.75 inches and a diameter of 4.50 inches.
How to Weld ELASTIMOLD Apparatus Bushings and Bushing Wells
This guide provides recommended procedures and safety precautions for welding ELASTIMOLD apparatus bushings and bushing wells, focusing on minimizing heat to maintain product integrity.
Estimated time: 1h
Tools needed:
TIG welding equipment, MIG welding equipment, Thermocouple detectors, Copper heat sinks
Supplies needed:
No. 308 bare stainless steel wire, Thermally conductive paste, HV insulated caps or connectors, Cleaning agents
- Prepare Apparatus and Workspace
DANGER: De-energize all apparatus before beginning. Inspect all parts for damage, proper rating, and compatibility. Ensure the installation area is clean and all required tools and supplies are at hand. Remove any protective shipping covers and replace them with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Ensure the clearance between the epoxy shank and the mounting hole is 3/16” ± 1/16”. Remove all burrs from the mounting hole and finish with a 1/16” radius.
- Set Up Heat Sinks and Clean Surfaces
Install copper heat sinks to minimize heat flow to the epoxy. Apply thermally conductive paste at the face of the heat sinks in contact with the flange and cover. Ensure venting is provided for the heat sinks. Position the bottom heat sink to be of larger diameter than the top. DANGER: Do not thread heat sinks to the bushing or bushing well stud. Thoroughly clean all surfaces (tank, bushing, and bushing well) to remove contamination like paint or grease, which can extend welding time and affect bushing integrity.
- Perform Welding with Heat Control
Perform welding using either Inert-gas, tungsten-arc (TIG) or Short-arc (MIG) processes with No. 308 bare stainless steel wire. Keep heat to a minimum; the visible heat line should not be greater than 1/8” from the weld and 3/16” from the O.D. of the flange. Minimize air currents in the welding area. Use thermocouple detectors to ensure temperatures at critical points do not exceed 225°F. Minimize forces applied to the heated stud and flange during and after welding. If using non-water-cooled heat sinks, remove them promptly after welding and air cool the bushing.
- Final Checks and Curing
Ensure the oil level covering the immersed stud connection is greater than 2 inches. If the equipment surface requires thermal baking to cure its finish, ensure the bake sequence does not exceed 130°F or 8 hours to prevent damage to the bushings. During this curing process, the bushing metallic contacts should not be mechanically loaded internally or externally to prevent epoxy distortion. IMPORTANT: ELASTIMOLD bushings are not designed for use in air, except for the 600T1 with boots and collars.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.