Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV, 900 Amp Deadbreak 3-Way Junction
- Fully shielded, fully submersible molded rubber housing
- 100% peroxide-cured construction with insulation and conductive EPDM
- Mates with Elastimold® 900 A Series Elbow connectors
- Includes stainless steel mounting bracket and back plate
Specifications
Application | 15/25 kV, 900 Amps |
Connection Type | Deadbreak |
Current Rating | 900 A |
Material | Molded Rubber |
Material | Copper |
Mounting Type | Stainless Steel Mounting Bracket |
Poles | 3 |
Poles | 3-point |
Series | K675 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Junction 3-Point |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 19.0500 L |
Package Weight (Metric) | 8.6410 kg |

K650RTWSP
15/25kV 600 Series Deadbreak Reducing Tap Well wih factory assembled stud which is not field removable.Frequently Asked Questions
What is the K675J3 product?
The K675J3 is a 15/25kV, 900 Amp Deadbreak 3-Way Junction. It features a fully shielded, fully submersible molded rubber housing.
What standard does the K675J3 junction meet?
The K675J3 junction meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating for the 28kV class?
For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).
What is the impulse withstand rating for the 15kV class?
For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).
What products are compatible with the K675J3 junction?
The K675J3 mates with Elastimold® 900 A Series Elbow connectors. It also mates with K675 Elbow Connector, K675BE Bushing Extender, and 675BEA3 Bushing Adapter.
What is the maximum operating voltage for the 28kV class?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and the maximum phase-to-phase is 28kV.
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.
What is the continuous current rating for the K675J3?
The K675J3 has a continuous current rating of 900 Amps for both 15kV and 28kV voltage classes.
What are the applications for the K675J3 junction?
The K675J3 junctions are designed for subsurface, vault, or padmount applications. They can be used for sectionalizing, looping, tapping, and equipment bypass.
What is included in the K675J3 kit?
Each kit contains one basic molded junction K675J3, mounting hardware 600J3-6, two tubes of lubricant 82-08, installation instructions IS-0207, and three protective caps 675PPC-01.
How to Install the K675-J3 Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for installing the K675-J3 Deadbreak Junction using the Universal Mount method. It covers mounting, assembly, grounding, and initial setup procedures for sectionalizing, looping, or tapping electrical circuits. Always ensure all apparatus is de-energized before installation.
Estimated time: 1h
Tools needed:
Wrenches or Sockets (for 3/8" and 1/2" hex nuts and cap screws), Marker, Wire strippers, Screwdriver (for grounding lug, if applicable), Cleaning cloths
Supplies needed:
K675-J3 Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware (3/8” hex head cap screws, external tooth lock washers, 3/8” hex nuts, 1/2” hex head cap screws, 1/2” split lock washers, 1/2” hex nuts), Fasteners (suitable for mounting universal brackets to surface, user-supplied), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (for unused bushings)
- De-energize and Inspect Components
Before beginning any work, ensure all apparatus is completely de-energized. Inspect all components for any signs of damage, verify their ratings, and confirm compatibility with all mating parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.
- Mark Mounting Location
Determine the desired location for the junction assembly on the flat mounting surface. Use the base plate as a template, place it on the surface, and accurately mark all four slot locations where the universal brackets will be attached.
- Mount Initial Universal Brackets
Attach two (2) universal brackets to the marked surface using suitable fasteners (user-supplied). Tighten these fasteners securely to ensure there will be no movement of the brackets during operation.
- Attach Remaining Universal Brackets
Attach the remaining two (2) universal brackets to the two brackets already mounted on the surface, positioning them at the desired angle. Use the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten all connections securely.
- Assemble Junction to Base Bracket and Plate
Assemble the deadbreak junction to the base bracket assembly and base plate. Secure them using two (2) supplied 1/2” hex head cap screws, two (2) 1/2” split lock washers, and two (2) 1/2” hex nuts. Attach these to the center mounting holes on the bracket assembly and tighten securely.
- Attach Junction Assembly to Universal Brackets
Attach the complete deadbreak junction assembly to the previously mounted universal brackets. Use the supplied 1/2” split lock washers, 1/2” hex nuts, and 1/2” hex head cap screws. Ensure the parking stand is in an upright position and tighten all hardware securely.
- Ground the Assembly
Ensure the base bracket assembly and the junction’s black conductive jacket are properly grounded. Connect a suitable grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket for this purpose.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces and clean them thoroughly. Lubricate each interface with an ELASTIMOLD approved lubricant. It is critical not to substitute with other lubricants, as they may be harmful to this product or its mating components.
- Install Insulated Caps on Unused Bushings
If not all operating interfaces will be utilized, install appropriate HV insulated caps on any unused bushing(s) before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated and are only for handling and installation.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.