ABB - Installation Products K650ETP - 600 Amp, 25kV, 600 Series Loadbreak Elbow Tap Plug, use 600ATM assembly tool. Length 9.861 inches, Widest Diameter 3 inches.
More images

ABB Installation Products K650ETP 600 Amp, 25kV, 600 Series Loadbreak Elbow Tap Plug, use 600ATM assembly tool. Length…

UPC: 783786630615


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB K650ETP is a 25kV, 600/200A loadbreak elbow tap plug designed for medium-voltage distribution systems. This Elastimold® product enables a 200A tap from a 600A mainline connector, providing a reliable loadbreak interface for energized operation. The K650ETP is rated for 25kV phase-to-phase voltage with a maximum operating voltage of 26.3kV and a 125kV BIL impulse withstand rating (1.2 x 50 microsecond wave). It supports continuous current of 200A at the loadbreak interface and 600A at the deadbreak interface, with momentary ratings of 10kA symmetrical for 10 cycles and 25kA symmetrical for 10 cycles, respectively. The elbow tap plug features a hex-broach design for precise torque control during installation, ensuring consistent performance. Its peroxide-cured insulation and jacket provide durability in harsh environments, including exposure to moisture, UV radiation, and temperature fluctuations. The K650ETP meets ANSI/IEEE Standard 386 and includes a protective shipping cap, lubricant, and installation instructions. Compatible with the ABB 600ATM assembly tool, the K650ETP simplifies installation and removal in confined spaces such as vaults, manholes, and pad-mounted transformers. It mates with a range of Elastimold® products, including 273DR, 273DRG, 273ESA-XX, 275LR, and others, ensuring versatility in medium-voltage applications. The compact dimensions (9.861 inches in length and 3 inches in widest diameter) allow for tight installations in underground residential, commercial, and industrial systems where reliable loadbreak operation is critical.
  • 25kV rated, 26.3kV max phase-to-phase voltage
  • 600/200A loadbreak interface with 125kV BIL impulse withstand
  • Hex-broach design for precise torque control during installation
  • Peroxide-cured insulation and jacket for durability in harsh environments
  • Compatible with ABB 600ATM assembly tool for simplified installation

Specifications

Application
25kV, 600 Amps
Current Rating
600 A
Material
EPDM-Rubber
Size
Length 9.86 inch, Diameter 3 inch
Size
9.861 inches x 3 inches
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Loadbreak Elbow Tap Plug
Voltage Rating
25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.9700 L
Package Weight (Metric)
0.8940 kg
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.

K675TBC

15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
35kV 600 Series Deadbreak Bushing Extender - Length 10.27 inch x 3.17 inch Diameter. (with Stud - Length 2.28 inch 5/8-11 UNC-2A Thread).

755BE

35kV 600 Series Deadbreak Bushing Extender - Length 10.27 inch x 3.17 inch Diameter. (with Stud - Length 2.28 inch 5/8-11 UNC-2A Thread).
25kV 600 Series Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op.

K650LRTPA2

25kV 600 Series Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op.
15kV 600 Amp Series Loadbreak Elbow Tap Plug. Use 600ATM assembly tool.

650ETP

15kV 600 Amp Series Loadbreak Elbow Tap Plug. Use 600ATM assembly tool.
600 Amp, 35kV, 600 Series Deadbreak 2-Way VS-Kit, does not include cable adapter or compression lug.

755VS-L2

600 Amp, 35kV, 600 Series Deadbreak 2-Way VS-Kit, does not include cable adapter or compression lug.
35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug

750ETP

35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug
35kV, 600 Amp Series, Deadbreak Elbow Threaded Stud. Aluminum. Length 2.28 inch. Threaded Length each end .84 inch.

750SA

35kV, 600 Amp Series, Deadbreak Elbow Threaded Stud. Aluminum. Length 2.28 inch. Threaded Length each end .84 inch.
25kV 600 Series Deadbreak Stick-Op Bushing Adapter

K655BEA2

25kV 600 Series Deadbreak Stick-Op Bushing Adapter

Frequently Asked Questions

What is the momentary rating for the deadbreak interface?

The 600 A Deadbreak Interface has a 25kA Sym – 10 Cycle Momentary rating.

What is the K650ETP elbow tap plug used for?

The K650ETP elbow tap plug permits a 200 Amp tap off of a mating 600 Amp connector.

What tool is required to install the K650ETP?

The K650ETP elbow tap plug is installed using a 600ATM assembly tool.

What products are compatible with the K650ETP?

The K650ETP mates with products such as 273DR, 273DRG, 273ESA-XX, 275LR, 275LRJS, 273ELR, 273RLR, 273DLR, 273DELR, and 370GLR.

What is the maximum phase-to-ground operating voltage?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.

What is the maximum phase-to-phase voltage rating?

The maximum phase-to-phase voltage rating for the 25kV voltage class is 26.3kV.

What is the impulse withstand (BIL) rating?

The impulse withstand (BIL) rating is 125kV, based on a 1.2 x 50 microsecond wave.

What is the one-minute AC withstand rating?

The one-minute AC withstand rating is 40kV AC.

What is the 15-minute DC withstand rating?

The 15-minute DC withstand rating is 78kV DC.

What is the corona extinction voltage?

The corona extinction voltage is 19kV AC at 3pC sensitivity.

How to Install the K650/675 ETP Elbow Tap Plug

This guide provides step-by-step instructions for the safe installation and connection of the K650/675 ETP Elbow Tap Plug, including cable preparation, lubrication, assembly, and grounding procedures. Ensure all apparatus is de-energized before beginning installation.

Estimated time: 1h

Tools needed:

Wire preparation tools, Torque wrench, Drive adapter

Supplies needed:

Lubricant (DO NOT SUBSTITUTE), Double-ended stud (if applicable), Spade contact, #14AWG copper wire or equivalent, Appropriate grounding connector, Jumper of equivalent ampacity, Appropriate waterproofing, DR(G), ESA, GLR, LR, or insulated cap/elbow arrester of appropriate voltage class

  1. Ensure Safety and Inspect Components

    De-energize all apparatus before beginning installation. Inspect all components for damage, proper rating, and compatibility with mating parts. Ensure all parts fit correctly with the cable and/or mating products. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare Cable and Install Elbow

    Prepare the cable using a spade contact and install the elbow as described in the (K)650LR or 750LR installation instructions. Before making the first crimp on the spade contact, align it on the cable so that the spade lies flat on the apparatus bushing contact.

  3. Prepare Connectors and Lubricate

    Remove the protective caps from the elbow connector and the tap plug. Finger tighten the double-ended stud (if applicable) into the tap plug. Clean and thoroughly lubricate the entire mating connector interface, elbow connector interfaces, and the tap plug using only the supplied lubricant or an ELASTIMOLD approved lubricant.

  4. Assemble Elbow and Tap Plug

    Assemble the elbow connector onto the mating connector. Then, assemble the tap plug into the elbow connector. Insert the drive adapter into the tap plug. Turn the drive adapter in a clockwise direction while simultaneously pushing the elbow and tap plug toward the mating connector. Continue rotating the drive adapter clockwise with an appropriate tool to a torque of 50-60 ft-lbs. Remove the drive adapter from the tap plug.

  5. Install Grounding Eye Wire

    Insert one end of a length of #14AWG copper wire (or equivalent) through the grounding eye of the elbow, leaving sufficient length to allow movement of the elbow if required. Make a small loop and twist it tightly, taking care not to damage the grounding eye.

  6. Ground Concentric Wire Shielded Cable

    If using concentric wire shielded cable, twist the shield wires together. Connect these twisted shield wires and the grounding eye wire to ground using an appropriate connector. For three-phase installations, all grounds from all three phases must be tied to a common ground point. If the cable is jacketed, install appropriate waterproofing at the jacket terminus to prevent moisture from entering.

  7. Ground Metallic Tape Shielded Cable

    If using metallic tape shielded cable, connect the metallic shield of the cable to ground using a jumper of equivalent ampacity to the metallic shield. Install appropriate waterproofing at the jacket terminus to prevent moisture from entering. Connect the elbow connector grounding eye wire to ground.

  8. Install Final Connector or Cap

    Clean and lubricate the entire tap plug interface. Install a DR(G), ESA, GLR, or LR of the appropriate voltage class onto the tap plug interface, following the instructions supplied with each of these products.

  9. Verify Seating Indication

    Complete assembly of an insulated cap or elbow is indicated by no portion of the yellow seating indicator being visible when viewed from the side.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.