The ABB 755BE 35kV 600 Series Deadbreak Bushing Extender (SKU: 755BE) is a fully shielded, submersible accessory designed to increase the distance between apparatus surfaces and cable entry points in medium-voltage systems. Rated for 35kV systems with a maximum phase-to-ground operating voltage of 21.1kV and phase-to-phase voltage of 36.6kV, this bushing extender meets ANSI/IEEE Standard 386 for deadbreak connectors. It features a 900A continuous current rating, 25kA symmetrical momentary rating (10 cycles), and a 150kV BIL impulse withstand (1.2 x 50 microsecond wave). The 10.27-inch length and 3.17-inch diameter housing accommodates tight enclosures while the 5/8-11 UNC-2A threaded stud enables direct attachment to ABB 600 Series deadbreak bushings without additional hardware. Constructed with 100% peroxide-cured EPDM materials for insulation and conductivity, the extender ensures safe, load-break-free connections in de-energized states using standard hand tools. Ideal for retrofitting installations requiring additional clearance, extending bushing wells in switchgear, or adapting terminations in confined spaces. Compatible with ABB 600 Series connectors including 775CP, 775BIP, 775J2/3/4, 775ETP, 775S1, and 775T1. Corona extinction at 26kV AC with 3pC sensitivity guarantees minimal electrical interference. No special training beyond basic medium-voltage electrical safety is required for installation.
  • 35kV rated with 21.1kV phase-to-ground and 36.6kV phase-to-phase operating voltage
  • 900A continuous current, 25kA momentary rating (10 cycles)
  • 150kV BIL impulse withstand and 50kV AC one-minute withstand
  • 10.27" length x 3.17" diameter housing with 5/8-11 UNC-2A threaded stud
  • Fully shielded, submersible, and compatible with ABB 600 Series deadbreak bushings

Specifications

Application
35kV, 600 Amps
Connection Type
5/8-11 UNC-2A Thread
Material
EPDM-Rubber
Series
600 Series
Size
Length 10.27 inch x 3.17 inch Diameter
Size
10.27 inch x 3.17 inch
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Deadbreak Bushing Extender
Voltage Rating
35 kV
Package Dimensions (L x W x H)
12 IN x 4 IN x 4 IN
Package Dimensions (L x W x H)
30.48 cm x 10.16 cm x 10.16 cm
Package Weight (Imperial)
2.2200 L
Package Weight (Metric)
1.0070 kg
35kv, 200 Amp Loadbreak Bushing Clamp and Gasket Kit - 3 Holes, for use on Bushing Well without Bail Tabs. Equipped with Copper Conductor Rod. Molded Epoxy Flange for Gasketed Clamp Mounting. Includes Epoxy Bushing Well, Clamp, Gasket and Instruction Sheet.

L1601PC-S2-CK3H

35kv, 200 Amp Loadbreak Bushing Clamp and Gasket Kit - 3 Holes, for use on Bushing Well without Bail Tabs. Equipped with Copper Conductor Rod. Molded Epoxy Flange for Gasketed Clamp Mounting. Includes Epoxy Bushing Well, Clamp, Gasket and Instruction Sheet.
25kV 600 Series Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op.

K650LRTPA2

25kV 600 Series Stick-Op Loadbreak Reducing Tap Plug, 600AT assembly tool required for operation and/or installation of Stick-Op.
15kV 600 Amp Series Loadbreak Elbow Tap Plug. Use 600ATM assembly tool.

650ETP

15kV 600 Amp Series Loadbreak Elbow Tap Plug. Use 600ATM assembly tool.
600 Amp, 35kV, 600 Series Deadbreak 2-Way VS-Kit, does not include cable adapter or compression lug.

755VS-L2

600 Amp, 35kV, 600 Series Deadbreak 2-Way VS-Kit, does not include cable adapter or compression lug.
35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug

750ETP

35kV 600 Series Deadbreak, Loadbreak Elbow Tap Plug
35kV, 600 Amp Series, Deadbreak Elbow Threaded Stud. Aluminum. Length 2.28 inch. Threaded Length each end .84 inch.

750SA

35kV, 600 Amp Series, Deadbreak Elbow Threaded Stud. Aluminum. Length 2.28 inch. Threaded Length each end .84 inch.
25kV 600 Series Deadbreak Stick-Op Bushing Adapter

K655BEA2

25kV 600 Series Deadbreak Stick-Op Bushing Adapter
Window-op, Operating Kit, Contains Grounding Elbow Package, Test Rod Assembly, Lubricant, Instruction Sheets. Tool Bag.

650WINDOW-OK

Window-op, Operating Kit, Contains Grounding Elbow Package, Test Rod Assembly, Lubricant, Instruction Sheets. Tool Bag.

Frequently Asked Questions

What is the corona extinction voltage for the 755BE?

The corona extinction rating for the 755BE is 26kV AC at 3pC sensitivity.

What is the 755BE bushing extender's primary function?

It increases the distance between an apparatus surface and the cable entry point for a 600 A elbow connection.

What are the voltage ratings for the 755BE?

It is rated for 35kV voltage class, with a 21.1kV max phase-to-ground operating voltage and 36.6kV max phase-to-phase.

What is the continuous current rating of the 755BE?

The 755BE bushing extender has a continuous current rating of 600 Amps.

Is the 755BE bushing extender submersible?

Yes, the 755BE bushing extender features a fully shielded, fully submersible molded rubber housing.

What standards does the 755BE meet?

The 755BE bushing extender meets ANSI/IEEE Standard 386, Latest Revision.

What other Elastimold products are compatible with the 755BE?

It is compatible with Elastimold products including 751CP, 750BIP, 750J2, 750J3, 750J4, 750ETP, and 750T1.

What is included in the 755BE kit?

Each kit contains one 755BE housing, two tubes of lubricant 82-08, one stud 750SA, and installation instructions IS-0242.

What is the impulse withstand rating for the 755BE?

The 755BE has a 150kV BIL Impulse Withstand rating, measured with a 1.2 x 50 microsecond wave.

What is the momentary current rating of the 755BE?

The 755BE has a 25kA Sym momentary current rating for 10 cycles.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for the safe and proper installation of the LINK-C 600 amp deadbreak cam link operable connector system, including pre-installation checks, component assembly, lubrication, and grounding procedures. Ensure all safety warnings are observed.

Estimated time: 1h 30m

Tools needed:

Hot stick, Torque wrench, Suitable tool for 1 inch hex (e.g., socket wrench), Wire strippers, 600ATM Operating Tool

Supplies needed:

ELASTIMOLD supplied lubricant, #14 AWG or #12 AWG solid copper wire, Appropriate ground connector, Alignment bracket mounting hardware (hex bolts, lock washers)

  1. De-energize Apparatus and Inspect Components

    DANGER: De-energize all apparatus before beginning installation or removal of any parts. Do not touch or move energized products. Inspect all package contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Install 600 Amp Elbow onto Cable

    Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure it is positioned to align with the stand-off plug or apparatus bushing.

  3. Install Bushing Extender onto Apparatus Bushing

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing using a suitable tool applied to the 1 inch hex portion of the 600ATM. Torque to 50-60 ft-lbs.

  4. Install Elbow onto Epoxy Standoff Plug

    Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600AMT into the retainer contact through the compression lug hole, engage the internal hex broach, and thread into the epoxy standoff plug using a suitable tool applied to the 1 inch hex portion of the 600AMT. Torque to 50-60 ft-lbs.

  5. Install Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until clamp tabs are flush and tight.

  6. Position and Secure Elbow in Alignment Bracket

    Position the elbow in the alignment bracket so that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Insert Link into Bushing Extender and Elbow

    Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted. Insert the Link into the bushing extender and elbow, ensuring both lever arms are on the inside of the alignment bracket legs.

  8. Engage Link Mechanism

    Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick applied to the hot stick eye to move the lever arms downward. This action will engage the roller pin and move the Link inward. Continue moving the lever arms until they are perpendicular to the alignment bracket leg.

  9. Grounding and Mating Product Installation

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface per its installation instructions. Ground the cable; if concentric neutral, twist wires and connect to ground; if using 20MA or 21MA devices, connect their ground lead to ground. For three-phase installations, tie all grounds to a common ground point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.