UPC: 783786622849
Contact for Pricing
Overview
- 15kV voltage class with 8.3kV phase-to-ground and 14.4kV phase-to-phase ratings
- 200 Amp loadbreak and continuous current rating with 10kA symmetrical momentary rating
- 600 Amp deadbreak interface with 25kA symmetrical momentary rating
- Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand rating
- Requires 600ATM assembly tool for installation; mates with 167DR, 167ESA-XX, and 165LR series connectors
Specifications
Application | 15kV, 600 Amps |
Connection Type | Loadbreak Elbow Tap Plug |
Current Rating | 600 A |
Material | EPDM-Rubber |
Series | 650ETP |
Size | Length 8.61 inch, Diameter 3 inch |
Temperature Rating, Maximum | 194 F |
Temperature Rating, Maximum | 90 C |
Temperature Rating, Minimum | 194 F |
Temperature Rating, Minimum | 90 C |
Type | Loadbreak Elbow Tap Plug |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.5000 L |
Package Weight (Metric) | 0.6800 kg |

K650RTW
15/25kV 600 Series Deadbreak Reducing Tap Well. Length 5.37 inch. Width 3 inch not counting bracket. 600/200 Amps
755VS-L2
600 Amp, 35kV, 600 Series Deadbreak 2-Way VS-Kit, does not include cable adapter or compression lug.
750SA
35kV, 600 Amp Series, Deadbreak Elbow Threaded Stud. Aluminum. Length 2.28 inch. Threaded Length each end .84 inch.
650WINDOW-OK
Window-op, Operating Kit, Contains Grounding Elbow Package, Test Rod Assembly, Lubricant, Instruction Sheets. Tool Bag.
650LT-B
15kV LINK-OP LoadBreak, Reducing Tap Plug. 600AT assembly tool required for operation and/or installation of Link-Op. 600ATM is recommended for installing Link-Op/Cam-Op retaining sleeves.
K650LT-B
25kv LRTP-link, current carrying, Rubber, Aluminum, Copper, Plastic. 25kV LINK-OP LoadBreak, Reducing Tap Plug. 600AT assembly tool required for operation and/or installation of Link-Op. 600ATM is recommended for installing Link-Op/Cam-Op retaining sleeves.Frequently Asked Questions
How can I order the 650ETP with a factory-assembled stud?
To order the 650ETP with a factory-assembled stud, add "SP" to the part number.
What items are included in the 650ETP kit?
Each 650ETP kit contains one bushing insert, one protective shipping cap (1601-APC-1), two lubricants (82-08), and one installation instruction (IS-0766).
What is the 600A deadbreak interface continuous current rating?
The 600 A deadbreak interface has a 600 Amp continuous current rating.
What is the 200A loadbreak interface current rating?
The 200 A loadbreak interface is rated for 200 Amp continuous and loadbreak current.
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage for the 650ETP is 14.4kV.
What is the maximum operating phase-to-ground voltage?
The maximum phase-to-ground operating voltage for the 650ETP is 8.3kV.
What products are compatible with the 650ETP?
The 650ETP mates with products such as 167DR, 167DRG, 167ESA-XX, 165LR, 165LRJS, 167ELR, 167RLR, 167DLR, 167DELR, and 160GLR.
What tool is required for 650ETP installation?
The 650ETP is installed using a 600ATM assembly tool.
What is the primary function of the 650ETP?
The 650ETP elbow tap plug permits a 200 Amp tap off of a mating 600 Amp connector.
How can I order the 650ETP with a factory-assembled stud?
To order the 650ETP with a factory-assembled stud, add "SP" to the part number.
How to Install the 650/675 ETP Elbow Tap Plug
This guide provides step-by-step instructions for safely installing the 650/675 ETP Elbow Tap Plug, designed to provide a 200 ampere loadbreak tap at system voltage. Ensure all safety precautions are followed during installation.
Estimated time: 1h
Tools needed:
Torque wrench, Drive adapter, Wire strippers
Supplies needed:
650/675 ETP Elbow Tap Plug, Lubricant (supplied), Double-ended stud (if applicable), #14AWG copper wire, Grounding connector, Waterproofing material
- Perform Pre-Installation Checks and Safety Measures
DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products in the work area. Inspect all package contents for completeness and damage, and verify all components fit properly with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.
- Prepare Cable and Install Elbow Connector
Prepare the cable using a spade contact and install the elbow according to the (K)650LR or 750LR installation instructions. Before crimping, align the spade contact on the cable so it lies flat on the apparatus bushing contact.
- Prepare Tap Plug and Connectors
Remove the protective caps from both the elbow connector and the tap plug. If applicable, hand-tighten the double-ended stud into the tap plug. Thoroughly clean and then lubricate the entire mating connector interface, elbow connector interfaces, and the tap plug using only the supplied lubricant or an ELASTIMOLD approved lubricant.
- Assemble Elbow and Tap Plug
Assemble the elbow connector onto the mating connector. Then, assemble the tap plug into the elbow connector. Insert the drive adapter into the tap plug and turn it clockwise while simultaneously pushing the elbow and tap plug towards the mating connector. Continue rotating the drive adapter clockwise with an appropriate tool to achieve a torque of 50-60 ft-lbs. Finally, remove the drive adapter from the tap plug.
- Install Grounding Eye Wire
Insert one end of a length of #14AWG copper wire (or equivalent) through the grounding eye of the elbow. Leave sufficient length to allow for potential movement of the elbow. Form a small loop and twist it tightly, being careful not to damage the grounding eye.
- Connect Cable Shield and Grounding Eye Wire to Ground
For concentric wire shielded cable, twist the shield wires together and connect them, along with the grounding eye wire, to a common ground point using an appropriate connector. Ensure sufficient length for elbow movement. For metallic tape shielded cable, connect the metallic shield to ground using a jumper of equivalent ampacity, and connect the elbow connector grounding eye wire to ground. Install appropriate waterproofing at the jacket terminus to prevent moisture ingress for both cable types.
- Install Mating Component to Tap Plug
Clean and lubricate the entire tap plug interface. Then, install a DR(G), ESA, GLR, or LR of the appropriate voltage class to the tap plug interface, following the specific instructions provided with that product. Use only the supplied lubricant or an ELASTIMOLD approved lubricant.
- Verify Full Seating
Confirm the complete assembly of an insulated cap or elbow by visually checking that no portion of the yellow band is visible when viewed from the side. This indicates full seating.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.