ABB Installation Products K151SR-C0250 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…
UPC: 783786502004
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV rated deadbreak straight receptacle
- 200 Amp continuous current rating
- Accommodates cable insulation 0.805–1.060 inch diameter
- Aluminum compression lug for 2/0–3/0 AWG conductors
- Hot-stick operable for safe load-break operations
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR3B0250
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
167DLR-H5270
200 Amp, 15kV, Loadbreak Direct Test Elbow Connector, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Solid 250 or mmSquared 26.67.
K151SP-C0250
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
K151SR-C0230
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Solid 1/0 or mmSquared 42.41.
K151SP-C0230
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
168RLR-F5220-5240
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size 220 - AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Conductor Size 240 AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
K151SR-C0220
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.
K151SP-B2200
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.Frequently Asked Questions
What is the K151SR Deadbreak Straight Receptacle?
The K151SR is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus. It is suitable for 15kV and 25kV systems.
What is the 15kV maximum phase-to-ground operating voltage?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What standards does the K151SR meet?
The K151SR meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating for 25kV?
For the 25kV voltage class, the impulse withstand (BIL) is 125kV.
What is the impulse withstand rating for 15kV?
For the 15kV voltage class, the impulse withstand (BIL) is 95kV.
What is the 25kV maximum phase-to-ground operating voltage?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.
What cable insulation diameters are supported?
The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.
What conductor sizes does the K151SR accommodate?
The K151SR will accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What is the continuous current rating for the K151SR?
The K151SR has a continuous current rating of 200 Amp for both 15kV and 25kV voltage classes.
What voltage systems is the K151SR compatible with?
The K151SR is suitable for use on both 15kV and 25kV systems.
How to Install the K151SR/151SR Straight Receptacle
This guide provides step-by-step instructions for installing the K151SR/151SR Straight Receptacle, including cable preparation, crimping, lubrication, and connection to mating products for 15kV or 25kV class systems. Ensure all apparatus are de-energized and follow high-voltage safety practices.
Estimated time: 1h 30m
Tools needed:
Cable cutter, Wire strippers, Wire brush, Crimp tool, Rag
Supplies needed:
151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Solid dielectric type cable, Elastimold bail, #14 AWG copper wire (or equivalent), Silicone grease, Approved solvent, HV insulated cap(s) or connector(s) (optional), Elastimold Insulating Plug (K150DP) (optional)
- De-energize and Inspect Components
Before starting, ensure all apparatus are de-energized. Inspect all parts for damage, proper rating, and compatibility with the cable and mating products. Gather all required tools and maintain cleanliness throughout the procedure. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated cap(s) or connector(s) before submerging or energizing. A bailing arrangement is required when using this product with any mating Elastimold deadbreak product.
- Prepare Cable Jacket
For Jacketed Concentric Neutral Cable: Cut and remove 8 inches of cable jacket from the cable end, ensuring sufficient concentric neutral wires for grounding. For Copper Tape Shield Cable: Cut and remove 7 1/2 inches of cable jacket from the cable end, then remove copper tape shield 6 1/2 inches from the end of the cable. (Note: If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back).
- Prepare Insulation and Conductor
Remove 7/8 to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 to 1 7/8 inches. Wire brush bare aluminum conductors and immediately insert the conductor into the crimp barrel, ensuring it remains fully seated. Cut the conductor squarely; do not pencil the cut.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated. Start the crimps at the crimp line imprinted on the crimp barrel and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare Semi-Conductive Shield and Clean
Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut. Do not cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent to remove all traces of semi-conducting residue, wiping from the cable end toward the outer jacket. If using an ECS or MA grounding device, install it now following its specific instructions.
- Lubricate Cable and Receptacle
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable and to the inside of the housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.
- Insert Cable into Receptacle
Push the cable into the receptacle housing until the base of the pin chamfer is flush with the inside face of the receptacle. IMPORTANT: If the receptacle is not to be immediately connected, replace the protective cover. Note that the shipping cover offers protection from dirt only and is not an insulating device. If an insulating device is required, obtain an Elastimold Insulating Plug (K150DP).
- Connect to Mating Plug
Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail.
- Ground the Cable
If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.