ABB - Installation Products 168FLR3B0250 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

ABB Installation Products 168FLR3B0250 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 783786499809


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3B0250 molded current limiting fuse housing is designed for medium-voltage distribution systems requiring reliable fault protection. This housing accommodates 8.3kV nominal fuse voltage ratings and features two capacitive test ports for safe diagnostic access without system de-energization. The large housing supports cable insulation diameters from 0.635 inch to 0.905 inch (16-23mm), making it compatible with a range of conductor sizes including 2/0 AWG stranded/compressed and 3/0 AWG solid/compact aluminum conductors. This fuse housing is engineered for use in pad-mounted transformers, switchgear, and underground distribution systems where space efficiency and fault isolation are critical. The molded construction provides environmental resistance against moisture, contaminants, and mechanical stress, ensuring long-term reliability in outdoor and indoor installations. The capacitive test ports enable quick verification of fuse status, reducing maintenance downtime and improving operational safety. Key applications include utility substations, commercial and industrial power distribution, and renewable energy integration where medium-voltage protection is required. The ABB 168FLR3B0250 is part of ABB Installation Products' portfolio, a trusted manufacturer in electrical infrastructure solutions.
  • Nominal fuse voltage rating: 8.3kV
  • Two capacitive test ports for safe diagnostics
  • Supports cable insulation diameters: 16-23mm (0.635-0.905 inch)
  • Compatible with 2/0 AWG stranded/compressed and 3/0 AWG solid/compact aluminum conductors
  • Molded construction for environmental resistance in outdoor/indoor installations

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
Molded Construction
Material
EPDM-Rubber
Series
168FLR3B
Size
Cable Insulation Diameter 0.635-0.905 inch (16-23mm)
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact. With Jacket Seal

168FLR1B5250-S

8.3kV, 200 Amp, LoadBreak, Fused Elbow (Full Range Current Limiting). Small Housing. Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Connector, Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact. With Jacket Seal
600 Amp, Dead Break, Elbow Connector, Cam-Op Connector Kit, 15KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

655LINKCLRJ0270BDRG

600 Amp, Dead Break, Elbow Connector, Cam-Op Connector Kit, 15KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

755L2-M0300-S

600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.
25kV, Fused Elbow Housing - Full Range Current Limiting Fuse, with Test Point. Cable Insulation Diameter C - 0.805-1.060 inch, Conductor Size 230 is #1 Stranded/Compressed, 1/0 Compact/Solid. Aluminum Connector.

274FLR-C0230

25kV, Fused Elbow Housing - Full Range Current Limiting Fuse, with Test Point. Cable Insulation Diameter C - 0.805-1.060 inch, Conductor Size 230 is #1 Stranded/Compressed, 1/0 Compact/Solid. Aluminum Connector.
600 Amp, Dead Break, Elbow Connector, Retrofit Cam-Op Connector Kit, 15 KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000. Options AEBED

655LINKCLRN0410AEBED

600 Amp, Dead Break, Elbow Connector, Retrofit Cam-Op Connector Kit, 15 KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000. Options AEBED
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR3-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
15 kV, 200 Amp Loadbreak Repair Elbow without Test Point. Cable Insulation Diameter 0.740 to 0.950 inch. #1 Stranded/Compressed or 1/0 Solid/Compact.

167ELR-7495-230

15 kV, 200 Amp Loadbreak Repair Elbow without Test Point. Cable Insulation Diameter 0.740 to 0.950 inch. #1 Stranded/Compressed or 1/0 Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

168AFLR1-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

Frequently Asked Questions

What is the AC one-minute withstand voltage for the 168FLR?

The AC one-minute withstand voltage for the 168FLR is 34kV.

What is the 168FLR Loadbreak Fused Elbow used for?

It protects light duty underground distribution systems, including sub-loops and radial taps, by replacing existing 200 Amp loadbreak tap elbows.

What voltage class is the 168FLR designed for?

The 168FLR is designed for the 15kV voltage class, with an 8.3kV nominal fuse voltage and 10kV maximum rated fuse voltage.

What is the current rating range for the 168FLR?

The current rating for the 168FLR Loadbreak Fused Elbow ranges from 3 to 80 Amps.

What is the symmetrical interrupting capability of the 168FLR?

The 168FLR has a symmetrical interrupting capability of 50,000 Amps.

Is the 168FLR Loadbreak Fused Elbow submersible?

Yes, the 168FLR Loadbreak Fused Elbow is fully sealed and submersible.

How is a blown fuse indicated on the 168FLR?

The 168FLR has built-in voltage test points for quick and convenient blown fuse indication.

How is fuse replacement performed on the 168FLR?

The 168FLR features a split center section designed for easy fuse replacement.

What standards does the Elastimold 168FLR meet?

The Elastimold 168FLR meets applicable portions of IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are for copper conductors only. Bi-metal compression lugs are suitable for both copper or aluminum conductors.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides detailed instructions for the installation and assembly of the 168FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and neutral connection.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Allen Wrench, Wire brush, Crimp tool, Hotstick

Supplies needed:

Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, Optional 200ECS Cold Shrink Cable Seal, No. 14 AWG / 2.5mm copper wire, Terminal connectors

  1. Perform Safety and Pre-Installation Checks

    DANGER: All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility. Check package contents, component fit, and probe threads. Read all instructions before starting and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Termination

    Using the bushing centerline as a reference, cut excess cable, slide on the optional 200ECS Cold Shrink Cable Seal, and remove the jacket for the specified length. Unwrap and fold the Concentric Neutral wires back over the jacket and bind them. Squarely cut off the cable to the specified 'A' distance, leaving 7-3/8 inches minimum for termination.

  3. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches squarely from the cable end, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Lubricate and Insert Cable into Cable Half Housing

    Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This ensures the fuse can be tightened before bottoming on the rubber.

  5. Install and Hand Tighten the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. CAUTION: The fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.

  6. Assemble Probe Connector and Align Test Point

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position and tighten the setscrews using the special torque-limiting allen wrench supplied. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Halves and Insert Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4 inch. Ensure the probe connector faces the opening of the fused elbow half and that the two test points are in line. Insert the probe into the probe connector, pushing on the cable if necessary for alignment. Start the threads by hand, taking care not to cross-thread. Tighten using the special torque-limiting allen wrench supplied until the wrench bends and remains bent. Position the hose clamp as shown and tighten, DO NOT OVERTIGHTEN.

  8. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires, exercising care not to damage grounding eyes, and connect to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  9. Connect Elbow to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection using a full insulated 'hotstick' type tool; DO NOT OPERATE BY HAND. Refer to operating instructions for proper loadmake procedures, ensuring firm footing and positive control, and pushing the elbow home with a fast, firm, straight motion to engage the internal lock.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.