Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SP-A0250 - Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products K151SP-A0250 Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.575 inch to…

UPC: 783786491384


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SP-A0250 is a 200 Ampere straight plug deadbreak termination designed for medium-voltage applications up to 25kV. This deadbreak connector accommodates cable insulation diameters between 0.575 inch and 0.740 inch, making it compatible with a range of medium-voltage cables. The unit features an aluminum compression lug rated for compressed stranded conductors from 2/0 AWG to 3/0 AWG, or solid conductors up to 67.43 square millimeters, ensuring reliable electrical contact and mechanical strength. This deadbreak plug is engineered for use in underground distribution systems, pad-mounted transformers, and switchgear where safe, load-break connections are required without interrupting service. The deadbreak design allows for connection and disconnection under full load conditions, reducing downtime during maintenance or system reconfiguration. The aluminum compression lug provides a low-resistance interface with the conductor, minimizing heat generation and improving long-term reliability.
  • 200 Ampere deadbreak straight plug termination
  • Rated for 15kV and 25kV medium-voltage applications
  • Accepts cable insulation diameters from 0.575" to 0.740"
  • Aluminum compression lug for 2/0–3/0 AWG or 67.43mm² conductors
  • Designed for load-break connections in underground and pad-mounted systems

Specifications

Amperage Rating
200 A
Application
Designed to Terminate UD Cable having Concentric Neutral and Extruded instalation shielding
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
8.81 in
Length
223.774 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Plug
Voltage Rating
15 to 25 kV
Width
2.55 in
Width
64.77 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-B0250

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

273RLR-J-5230

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
15/25kV 200 Amp, Deadbreak Straight Plug Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-B2250

15/25kV 200 Amp, Deadbreak Straight Plug Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

168ELR-6689-5210

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.

755LR-L0290

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K151SR-C0270

15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

168ELR-6689-5220

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

Frequently Asked Questions

What Elastimold products is the K151SP compatible with?

The K151SP is designed to mate with the Elastimold K151T tee splice and K151SR straight receptacle.

What cable insulation diameters are supported?

The K151SP supports cable insulation diameters from 0.575 inches to 1.220 inches.

What conductor sizes are compatible with the K151SP?

The K151SP accommodates conductor sizes from No. 4 solid through 4/0 stranded.

What cable types can the K151SP terminate?

It is designed to terminate UD cable with concentric neutral and extruded insulation shielding. It can also terminate other cable types with a proper Elastimold® cable shield adapter.

What is the impulse withstand voltage (BIL)?

The impulse withstand (BIL) is 95kV for the 15kV class and 125kV for the 25kV class.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 200 Amps.

What is the maximum operating voltage for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV and maximum phase-to-phase is 26.3kV.

What is the maximum operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What is the K151SP product type?

The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug. It features a fully shielded, fully submersible molded rubber housing.

What is the K151SP product type?

The K151SP is a 15/25kV, 200 Amp Deadbreak Straight Plug. It features a fully shielded, fully submersible molded rubber housing.

How to Install the K151SP Straight Plug on Solid Dielectric Cable

This guide provides step-by-step instructions for preparing solid dielectric type cable and installing the K151SP Straight Plug, designed for 15kV and 25kV class systems. Ensure all safety precautions are followed.

Estimated time: 1h

Tools needed:

Cable cutting tool, Cable stripping tool, Wire brush, Crimp tool, Rag

Supplies needed:

K151SP Straight Plug (includes conductor contact, nylon venting rod, lubricant), Solid dielectric type cable, Approved solvent, Silicone grease, Elastimold bail (required), Grounding wire (#14 AWG copper or equivalent, if not using Elastimold grounding device)

  1. De-energize Apparatus and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Ensure all components are complete, undamaged, and compatible with the cable and mating products. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable Jacket and Shield

    For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the cable end. For Copper Tape Shield cable, cut and remove the cable jacket 7-1/2 inches from the cable end, then remove the copper tape shield 6-1/2 inches from the end of the cable. Allow sufficient concentric neutral wires for grounding as required.

  3. Prepare Conductor and Crimp Socket Terminal

    Remove 7/8 to 1 inch (or 1-3/4 to 1-7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield, cutting squarely. Do not pencil. Wire brush bare aluminum conductors immediately and insert into the crimp barrel containing inhibitor. Crimp the socket terminal on the bared conductor, holding the crimp barrel against the cable insulation. Start crimps at the crimp line and rotate each successive crimp 90 degrees. Carefully wipe excess inhibitor from the contact and cable insulation.

  4. Prepare Semi-conductive Shield and Clean Insulation

    Temporarily remove the plastic pin. Remove the semi-conductive shield to a point 7-3/4 to 7-13/16 inches back from the end of the socket with a straight, smooth, 'squared' cut. Do not cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent, always wiping from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its instructions.

  5. Lubricate Cable and Position Collar

    Slide the collar, smaller end first, onto each cable. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. Do not substitute lubricants, as others may be harmful to the product.

  6. Install Plug onto Cable

    Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.

  7. Connect to Mating Receptacle

    Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1-3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).

  8. Establish Ground Connection (if no Elastimold device)

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist tightly. Then, connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.