ABB - Installation Products K151SR-A0220 - 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products K151SR-A0220 15/25kV 200 Amp, Deadbreak Straight Receptacle, Bails are required, but not included…

UPC: 783786469406


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-A0220 is a deadbreak straight receptacle rated for 15/25 kV and 200 A continuous current, designed for medium-voltage cable terminations in industrial and utility applications. The cable insulation diameter range of 0.575 inch to 0.740 inch ensures compatibility with standard medium-voltage cable constructions, providing flexibility in system design. This deadbreak receptacle is part of ABB’s Installation Products line, optimized for reliability in underground and overhead distribution systems where maintenance-free, load-break operations are required. The compression lug design eliminates the need for soldering or crimping tools, reducing installation time while maintaining consistent electrical performance. Note that bails are required for proper installation but are not included; order separately to complete the termination assembly. Common applications include pad-mounted transformers, switchgear, and junction enclosures in utility substations, commercial buildings, and industrial facilities. The product’s voltage rating supports both 15 kV and 25 kV class systems, making it suitable for a wide range of medium-voltage distribution networks. The aluminum construction provides corrosion resistance and mechanical strength, ensuring long service life in harsh environments. For engineers specifying medium-voltage terminations, the K151SR-A0220 offers a proven solution with ABB’s engineering heritage. The product is fully tested to industry standards, delivering consistent performance in critical power distribution applications. When combined with compatible ABB accessories, this receptacle provides a complete, code-compliant termination system for medium-voltage cables.
  • Voltage Rating: 15/25 kV
  • Current Rating: 200 A
  • Cable Insulation Diameter: 0.575 inch to 0.740 inch
  • Material: Aluminum Compression Lug

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

K151SR-A2220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-A0220

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-A2220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

K151SP-D0220

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-D0240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4/mmSquared 16.76.

K151SP-B0190

Straight Plug, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4/mmSquared 16.76.
Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4 or mmSquared 16.76.

K151SR-B0190

Straight Receptacle, 200 Amp, DeadBreak, 15/25KV, Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Solid #4 or mmSquared 16.76.

Frequently Asked Questions

What is the 25kV impulse withstand rating for the K151SR?

For the 25kV voltage class, the K151SR has a 125kV BIL impulse withstand rating (1.2 x 50 microsecond wave).

What are the 25kV operating voltage limits for the K151SR?

For 25kV systems, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.

What is the 15kV impulse withstand rating for the K151SR?

For the 15kV voltage class, the K151SR has a 95kV BIL impulse withstand rating (1.2 x 50 microsecond wave).

What is the continuous current rating for the K151SR?

The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

What are the 15kV operating voltage limits for the K151SR?

For 15kV systems, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

What cable insulation diameter range does the K151SR accept?

The K151SR accommodates cable insulation diameters ranging from .575 inches through 1.220 inches.

What cable types and sizes are compatible with K151SR?

The K151SR terminates UD cable with concentric neutral and extruded insulation shielding. It accommodates conductor sizes from No. 4 solid through 4/0 stranded.

When can the K151SR's disconnectible feature be used?

The disconnectible feature of the K151SR can only be used when the electrical circuit is de-energized.

What is the K151SR product and its main features?

The K151SR is a 15/25kV, 200 Amp Deadbreak Straight Receptacle. It features a fully shielded, submersible molded rubber housing and 100% peroxide-cured construction.

What is the primary application of the K151SR receptacle?

The K151SR is a separable insulated connector designed to connect one cable to another cable or apparatus, suitable for 15 and 25kV systems.

How to Install the K151SR/151SR Straight Receptacle

This guide provides step-by-step instructions for preparing the cable, installing the conductor contact, and connecting the K151SR/151SR Straight Receptacle to a mating Elastimold product for high-voltage systems. Ensure all apparatus are de-energized before beginning.

Estimated time: 2h

Tools needed:

Wire strippers, Cable cutting tool, Wire brush, Crimping tool, Rag, Measuring tape or ruler, Approved solvent

Supplies needed:

K151SR/151SR Straight Receptacle (includes conductor contact, nylon venting rod, lubricant), Cable (solid dielectric type), Mating Elastimold plug or apparatus, #14 AWG or equivalent copper wire (customer supplied), Silicone grease (customer supplied), Elastimold bail (customer supplied)

  1. De-energize Apparatus and Inspect Parts

    DANGER: Ensure all apparatus are de-energized before installation or removal. Inspect all parts for damage, proper rating, and compatibility with mating components. This product should only be installed by competent personnel trained in high-voltage safety practices.

  2. Prepare the Cable Jacket

    Cut and remove the cable jacket. For jacketed concentric neutral cable, remove 8 inches. For copper tape shield cable, remove 7 1/2 inches of jacket and 6 1/2 inches of copper tape shield from the cable end. Allow sufficient concentric neutral wires for grounding.

  3. Remove Insulation and Conductive Shield

    Remove 7/8 to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 to 1 7/8 inches. Cut squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert into the crimp barrel containing inhibitor.

  4. Crimp the Conductor Contact

    Crimp the socket terminal onto the bared conductor. Ensure the conductor remains fully seated in the connector. Refer to the crimp chart provided with the contact. Start crimps at the crimp line and rotate each successive crimp or indent 90 degrees. For aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  5. Prepare Semi-conductive Shield and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut. DO NOT CUT OR NICK THE INSULATION. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end toward the outer jacket.

  6. Lubricate and Insert Cable into Receptacle

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown and to the inside of the housing. DO NOT SUBSTITUTE other lubricants. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle.

  7. Connect to Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring it is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an Elastimold bail.

  8. Ground the Cable

    If an ELASTIMOLD grounding device is not used, connect a length of #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.