Authorized ABB Distributor (Installation Products)
ABB - Installation Products 376LR-J-2260 - 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

ABB Installation Products 376LR-J-2260 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 783786521418


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 376LR-J-2260 is a fully rated 35kV, 200 Amp Class loadbreak elbow connector designed for reliable medium-voltage power distribution. Manufactured by ABB - Installation Products, this connector features a fully shielded, fully submersible molded rubber housing constructed with 100% peroxide-cured insulation and conductive EPDM materials. It is engineered to accommodate a wide range of cable insulation diameters from 0.980 inches to 1.180 inches (24.89 mm to 29.97 mm), ensuring broad compatibility with various cable sizes. The connector utilizes a bi-metal compression lug, suitable for copper or aluminum conductors, with a standard configuration for compressed stranded conductors from 3/0 AWG up to 4/0 AWG (85.01 mm²) and solid conductors up to 4/0 AWG. The 376LR-J-2260 includes a non-corrosive capacitive voltage test point, providing a crucial safety feature for voltage verification before de-energizing. It offers provision for hot stick operation, enabling loadmaking/loadbreak operations and a visible disconnect, along with a provision for ground wire connection. This connector meets ANSI/IEEE Standard 386, Latest Revision, for 35kV Voltage Class applications. Key ratings include 21.1kV Max Phase-to-Ground operating voltage, 36.6kV Max Phase-to-Phase, 150kV BIL impulse withstand, 50kV AC one-minute withstand, and 200 Amp continuous and loadbreak current. It also supports a 10kA Sym momentary and fault close rating for 10 cycles. The SKU for this specific model is 376LR-J-2260. Applications include electrical substations, utility networks, and industrial power systems requiring safe and efficient connection and disconnection of medium-voltage systems.
  • 35kV, 200 Amp Loadbreak Elbow Connector
  • Fully shielded, fully submersible molded rubber housing
  • Non-corrosive capacitive voltage test point for safety
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Bi-metal compression lug for copper or aluminum conductors

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

K151SR-D0270

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-K-5270

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR88110-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR-6689-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-B2240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.

167LRT-G5210-SG3

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-B2240

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

What is the voltage rating of the ABB 376LR-J-2260 connector?

The ABB 376LR-J-2260 loadbreak elbow connector has a voltage rating of 35kV.

What is the maximum current capacity for this elbow connector?

The ABB 376LR-J-2260 connector is rated for 200 Amps.

What cable insulation diameter range does this connector support?

This connector is designed for cable insulation diameters between 0.980 inches and 1.180 inches.

What type of lug is used for conductor connection?

The ABB 376LR-J-2260 features a copper compression lug for conductor connection.

What conductor sizes can be terminated with this connector?

It supports compressed stranded conductors from 3/0 AWG to 4/0 AWG (85.01 mm²) and solid conductors up to 4/0 AWG.

Does the connector include a test point?

Yes, the ABB 376LR-J-2260 loadbreak elbow connector includes a test point.

How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR and 376LR Loadbreak Elbow Connectors on UD cable, covering cable preparation, elbow assembly, and grounding procedures.

Tools needed:

Probe wrench, Crimp tool, Wire brush, Hotstick, Cable cut back template, Cable cutting tool, Wire strippers/knife

Supplies needed:

375LR or 376LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), UD Cable, No. 14 AWG (2.5mm) copper wire, Grounding connector, HV insulated cap(s) or connector(s)

  1. Prepare for Installation and Verify Components

    DANGER: De-energize all apparatus before beginning installation. Inspect all package contents for completeness and damage. Verify proper fit of all components with the cable and mating products. Thread the probe into the compression lug by hand to check for resistance; replace damaged components if resistance is encountered. Gather all required tools and maintain a clean work area.

  2. Train and Prepare Cable End

    Train the UD cable to allow for ease of operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut the excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 8-1/2 inches back from the cable end. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Remove the insulation shield as per the cable cut back template, beveling the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Install Compression Lug

    Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the compression lug's threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off any excessive inhibitor from the outside of the lug and cable.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant only; do not substitute. Keep insulation clean. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.

  5. Connect the Concentric Neutral

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the neutral wires to allow for elbow operation.

  6. Connect the Elbow to the Bushing

    WARNING: Only lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant if both the transformer and elbow are known to be de-energized. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.