Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SR-D0270 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

ABB Installation Products K151SR-D0270 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…

UPC: 783786518487


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-D0270 is a 200 Amp, 15/25kV deadbreak elbow straight receptacle designed for medium-voltage power distribution. Manufactured by ABB Installation Products, this component provides a fully shielded, fully submersible interface for terminating energized cables under load conditions. Its deadbreak design ensures safe operation during maintenance and reconfiguration without interrupting power flow. Key specifications include a continuous current rating of 200 Amps. For the 15kV voltage class, it supports an operating voltage of 8.3kV phase-to-ground (14.4kV phase-to-phase) and features a 95kV BIL impulse withstand rating. For the 25kV voltage class, it supports an operating voltage of 15.2kV phase-to-ground (26.3kV phase-to-phase) with a 125kV BIL impulse withstand rating. Both classes meet ANSI/IEEE Standard 386 and can handle momentary fault currents of 10kA symmetrical for 10 cycles. The receptacle accommodates cable insulation diameters ranging from 0.890 inches to 1.220 inches. It is designed for conductor sizes of 4/0 AWG compressed stranded aluminum or 250 kcmil solid aluminum (126.67 mm²), utilizing an aluminum compression lug for reliable termination. The housing is constructed from 100% peroxide-cured EPDM materials for durability and includes a provision for ground wire connection. The K151SR-D0270 is suitable for terminating UD cables with concentric neutral and extruded insulation shielding, or other cable types with appropriate shield adapters. It is designed to mate with compatible ABB products such as the K151T tee splice. Note that bails are required for installation and must be ordered separately. The SKU for this product is K151SR-D0270.
  • 200 Amp continuous current rating
  • 15/25kV voltage class (8.3/14.4kV and 15.2/26.3kV)
  • 95kV BIL (15kV) / 125kV BIL (25kV) impulse withstand
  • Accommodates 0.890" - 1.220" cable insulation diameter
  • Supports 4/0 AWG stranded / 250 kcmil solid aluminum conductors

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K151SR
Size
Cable Insulation Diameter 0.890 inch to 1.220 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-K-5270

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR88110-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR-6689-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SP-B2240

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes a copper compression lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.

167LRT-G5210-SG3

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.
15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

K151SR-B2240

15/25kV 200 Amp, Deadbreak Straight Receptacle (All Copper Lug), Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Includes 02800X Bi-Metal Contact.

167LRT-F5270

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Includes 02800X Bi-Metal Contact.

Frequently Asked Questions

What is the maximum cable insulation diameter supported?

The K151SR-D0270 deadbreak elbow receptacle supports cable insulation diameters ranging from 0.890 inches to 1.220 inches.

What conductor sizes can be terminated with this elbow?

This receptacle is designed for compressed stranded aluminum conductors from 4/0 AWG to 250 kcmil, or solid conductors up to 250 kcmil (126.67 mm²).

Are bails included with the deadbreak elbow receptacle?

No, bails are required for installation but are not included with the K151SR-D0270. They must be ordered separately.

What is the voltage rating of this deadbreak elbow?

The ABB K151SR-D0270 deadbreak elbow straight receptacle is rated for 15/25kV.

What type of lug is used for conductor termination?

This receptacle features an aluminum compression lug for secure conductor termination.

How to Install and Connect the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for preparing the cable, installing the 151SR/K151SR straight receptacle, and connecting it to a mating plug or apparatus on 15kV or 25kV class systems. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h

Tools needed:

Wire strippers, Wire brush, Crimping tool, Rag

Supplies needed:

151SR/K151SR Straight Receptacle kit, Solid dielectric type cable, Approved solvent, #14 AWG copper wire, Elastimold bail, Silicone grease

  1. Prepare Cable Jacket and Shield

    De-energize all apparatus before starting. For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut back.

  2. Prepare Conductor and Crimp Socket Terminal

    Remove 7/8 to 1 inch of cable insulation and conductive shield (or 1 3/4 to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable). Wire brush any bare aluminum conductors and immediately insert the conductor into the crimp barrel, which contains an inhibitor. Ensure the cut is square, do not pencil the conductor end. Crimp the socket terminal onto the bared conductor, verifying it remains fully seated. Start crimps at the crimp line and rotate each successive crimp 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.

  3. Prepare Insulation and Clean Cable Surface

    Remove the semi-conductive shield 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, "squared" cut. Do not cut or nick the insulation. Pencil the insulation 1/8 inch. Thoroughly clean the outer jacket and insulation with a rag wet with an approved solvent to remove all traces of semi-conducting residue, wiping from the cable end toward the outer jacket. If using an ECS or MA grounding device, install it now following its specific instructions.

  4. Lubricate and Install Receptacle Housing

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Sparingly apply the supplied lubricant to the cable as shown in the product diagram and to the inside of the receptacle housing. Do not substitute lubricants, as other types may harm the product or its mating part. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle will not be immediately connected, replace the protective cover (note: the shipping cover is not an insulating device; obtain an Elastimold insulating plug K150DP if insulation is required).

  5. Connect to a Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Carefully place the nylon rod into the receptacle face until it bottoms, approximately 1 3/4 inches, ensuring the rod is not cut. Insert the lubricated plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with an Elastimold bail.

  6. Ground the Cable Assembly

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist it tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.