ABB - Installation Products 756LR-N0380 - 600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

ABB Installation Products 756LR-N0380 600 Amp, 35KV, DeadBreak, Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and…

UPC: 783786515646


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-N0380 DeadBreak Elbow Connector is a fully shielded, dead-front submersible cable termination solution designed for 35kV medium-voltage applications. This 600 Amp connector features a built-in test point for diagnostic capabilities, enabling safe voltage verification without full disconnection. The kit includes an insulated plug, cap, stud, aluminum compression lug, and cable adapter, providing a complete termination system for cables with insulation diameters between 1.515 inches and 1.780 inches. Engineered to meet ANSI/IEEE Standard 386, the 756LR-N0380 supports conductor sizes from 700/750 kcmil (compressed stranded) to 900 kcmil (compacted solid) for both aluminum and copper cables. Its fully molded rubber housing is 100% peroxide-cured with EPDM materials, ensuring long-term reliability in submersible environments. The DeadBreak design allows safe connection and disconnection under de-energized conditions using standard hand tools, eliminating arc hazards during maintenance. Key electrical ratings include a maximum phase-to-ground operating voltage of 21.1kV, phase-to-phase voltage of 36.6kV, and a 150kV BIL impulse withstand rating. The connector also meets 50kV AC one-minute withstand, 103kV DC 15-minute withstand, and 26kV AC corona extinction at 3pC sensitivity. With a continuous current rating of 600 Amps and momentary rating of 25kA symmetrical for 10 cycles, this connector is ideal for medium-voltage power distribution systems in industrial, utility, and renewable energy applications. The 756LR-N0380 is part of ABB's Installation Products line, offering a robust solution for secure, reliable cable terminations in harsh environments. Optional accessories extend functionality for visible separation, bypass, isolation, grounding, and testing, making it a versatile choice for complex electrical systems.
  • 600 Amp continuous current rating for medium-voltage applications
  • Built-in test point for safe diagnostic voltage verification
  • Supports cable insulation diameters from 1.515" to 1.780"
  • Compatible with 700/750 kcmil stranded or 900 kcmil compacted solid conductors
  • Fully shielded, submersible molded rubber housing for harsh environments

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
8.9000 L
Package Weight (Metric)
4.0370 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

756LR-P0380

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

756LR-J0230

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

756LR-M0330

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Solid/Compact or 70 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-G-2250

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Solid/Compact or 70 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact or 250/300 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-K-0330

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact or 250/300 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

756LR-G0260

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-H-240

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

776LR-J5270-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What is recommended for metallic tape shield cable with 756LR?

When used on metallic tape shield or drain wire cable, an ECS cable seal grounding device is recommended.

What is the impulse withstand rating (BIL) of the connector?

The impulse withstand (BIL) rating is 150kV (1.2 x 50 microsecond wave).

What standard does the 756LR meet?

The 756LR meets ANSI/IEEE Standard 386, Latest Revision.

Is the 756LR elbow connector submersible?

Yes, the 756LR features a fully shielded, fully submersible molded rubber housing.

What insulation diameter range does the 756LR support?

The 756LR supports cable insulation diameters ranging from 0.760 inches to 2.120 inches.

What is the continuous current rating of the 756LR?

The 756LR elbow connector has a continuous current rating of 600 Amps.

What conductor sizes are compatible with the 756LR?

It is compatible with conductor sizes from #2 AWG to 1250 kcmil for aluminum and copper conductors.

What is the maximum operating voltage for the 756LR?

The maximum phase-to-ground operating voltage is 21.1kV, and maximum phase-to-phase is 36.6kV.

What is the primary application of the 756LR elbow connector?

The 756LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What is recommended for metallic tape shield cable with 756LR?

When used on metallic tape shield or drain wire cable, an ECS cable seal grounding device is recommended.

How to Install 756/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR and 776LR Deadbreak Elbow Connectors, designed for fully shielded, submersible cable connections to high voltage apparatus on 35kV class systems.

Estimated time: 2h

Tools needed:

Cable cutting tool, Cable cleaning supplies, Beveling tool, Wire strippers, Measuring tape, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

756/776LR Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Crimp connector, Lubricant, Stud Prepack), Grounding wire (No. 14 AWG Copper or equivalent), Suitable grounding connector, Silicone lubricant, Waterproofing material (for cable jacket), Mating product/apparatus bushing

  1. De-energize and Prepare Cable

    Ensure all apparatus is de-energized before beginning installation to prevent serious injury. Position the cable in its final assembled location with sufficient slack. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24 inches (610mm).

  2. Prepare Cable End and Install Adapter

    Carefully bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean the cable insulation, then lubricate it, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  3. Prepare Conductor and Crimp Lug

    Remove the protruding cable insulation, cutting it even with the end of the cable adapter. Ensure the exposed conductor length is between 4-3/8 inches to 4-3/4 inches (111mm-121mm). For aluminum conductors, wire brush the conductor immediately before insertion. Fully insert the conductor into the compression lug. Measure the 'Check Dimension' (should be less than 7 inches/178mm) before crimping. Crimp the lug according to its specific instructions, then wipe away any excess inhibitor.

  4. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Verify the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  5. Connect Elbow to Mating Product

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug hole with the stud. For the opposite end, clean and lubricate the mating part, insert it into the elbow, engage threads, hand tighten, and then torque according to the mating part's instructions.

  6. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper (or equivalent) wire through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded, either via a grounding device or an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  7. Perform Voltage Test

    If using the integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After voltage detection has been made, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.