Authorized ABB Distributor (Installation Products)
ABB - Installation Products K465LR-G-2250 - 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Solid/Compact or 70 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

ABB Installation Products K465LR-G-2250 15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter…

UPC: 783786632350


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K465LR-G-2250 is a 15/25kV, 630 Amp deadbreak elbow connector engineered for reliable underground distribution applications. This fully shielded, dead-front submersible connector provides a secure termination point for medium-voltage power systems, ensuring safe and insulated cable connections to high-voltage apparatus. The unit features a copper compression lug compatible with conductor sizes of 2/0 Stranded/Compressed, 3/0 Solid/Compact, or 70 mm², with a cable insulation diameter range of 0.760 to 0.950 inches (19.304 to 24.130mm). The deadbreak design allows for safe connection and disconnection in a de-energized state using standard hand tools, eliminating the need for test points in applications where testing at the elbow is unnecessary. The fully molded rubber housing, constructed from 100% peroxide-cured EPDM materials, ensures durability and resistance to environmental stressors, including submersion and corrosion. This connector is ideal for use with metallic tape shield or drain wire cables, with an ECS cable seal grounding device recommended for optimal performance. The kit includes all essential components: elbow connector housing, copper compression lug, stud, insulated plug with cap, tube lubricant, cable adapter, installation instructions, and crimp chart. Compatible with a range of Elastimold® accessories, the K465LR-G-2250 supports applications such as visible external separation, bypass, isolation, dead-ending, grounding, and testing. Its compact design and high dielectric strength make it suitable for confined spaces and critical infrastructure projects.
  • 15/25kV voltage class with 630 Amp continuous current rating
  • Deadbreak design for safe de-energized connection/disconnection
  • Compatible with 2/0 Stranded/Compressed, 3/0 Solid/Compact, or 70 mm² conductors
  • Cable insulation diameter range: 0.760–0.950 inches (19.304–24.130mm)
  • Fully molded EPDM rubber housing for submersion and corrosion resistance

Specifications

Amperage Rating
630 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Compression
Connection Type
Compression
Current Rating
630 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Copper
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 0.760-0.950 inches
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386/ IEC
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
7.2500 L
Package Weight (Metric)
3.2890 kg
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.

K675LR-J2250

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact or 250/300 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-K-0330

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact or 250/300 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.

756LR-G0260

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-H-240

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

776LR-J5270-S

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

274RLR-G-230

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

Frequently Asked Questions

What is the K465LR product used for?

The K465LR is an Elastimold deadbreak elbow connector designed for fully shielded, dead-front submersible cable connections to high-voltage apparatus.

Does the K465LR have a test point?

No, the K465LR is an elbow connector without a test point.

Is a grounding device needed for certain cables?

Yes, an ECS cable seal grounding device is recommended when the K465LR is used on metallic tape shield or drain wire cable.

What are the interface standards for the K465LR?

One end of the bushing interface conforms to IEC-71 for 630 A European Switchgear, while the other end has a standard ANSI 386 Fig 11 bushing interface.

What are the short circuit ratings for the K465LR?

The short circuit ratings are RMS symmetrical > 28 kA and peak asymmetrical > 70 kA.

What type of housing does the K465LR have?

The K465LR features a fully shielded, fully submersible molded rubber housing. It is constructed with 100% peroxide-cured insulation and conductive EPDM materials.

What insulation diameters does the K465LR support?

The K465LR supports cable insulation diameters from 0.640 inches to 1.935 inches.

What is the continuous current rating of the K465LR?

The K465LR has a continuous current rating of 630 Amps. It can handle up to 1250 Amps if the connected equipment is also rated for 1250A.

What conductor sizes are compatible with the K465LR?

The K465LR is compatible with aluminum and copper conductors ranging from 1/0 to 1250 kcmil.

What voltage class is the K465LR rated for?

The K465LR is fully rated for 15/25kV voltage class. Its maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

How to Utilize the M16 to 5/8-11 Thread Conversion Stud

This guide provides instructions for identifying and correctly applying the double-ended stud designed for converting M16 metric threads to 5/8-11 English threads in an assembly.

Estimated time: 5m

Supplies needed:

M16 to 5/8-11 Thread Conversion Stud

  1. Identify M16 Threaded End

    Locate the M16 threaded end of the conversion stud. This end is clearly marked with an 'M' for easy identification as per the documentation.

  2. Engage M16 Connection

    Carefully thread the identified M16 end of the stud into the corresponding M16 metric threaded port or component. Ensure a snug and secure fit, tightening appropriately for your application.

  3. Engage 5/8-11 Connection

    Attach the 5/8-11 English threaded component to the opposite end of the stud. Verify that both connections are fully engaged and stable for proper function.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.