ABB Installation Products 756LR-M0330 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…
UPC: 783786620012
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV 600 Series Deadbreak Elbow
- Integrated Test Point with Insulated Plug
- Includes Cap, Stud, Lug, and Cable Adapter
- Aluminum Compression Lug
- Cable Insulation Diameter: 1.370" - 1.630"
Specifications
Amperage Rating | 600 A |
Application | 35 kv, 600 Amp |
Color | Black |
Conductor Range | 500 kcmil , 600 kcmil |
Connection | Compression |
Connection Type | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Aluminum |
Material | Housing - EPDM-Rubber |
Series | 600 Series |
Size | Cable Insulation Diameter 1.370 inch to 1.630 inch |
Special Features | 35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Width | 12.28 in |
Width | 311.912 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 8.4300 L |
Package Weight (Metric) | 3.8240 kg |

755LR-L0330
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
K465LR-G-2250
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.760-0.950 inches (19.304-24.130mm). Copper Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Solid/Compact or 70 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
K465LR-K-0330
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch (27.686-33.274mm). Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact or 250/300 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
756LR-G0260
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
168RLR-H-240
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
776LR-J5270-S
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
274RLR-G-230
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.Frequently Asked Questions
What is the primary use of the 756LR elbow?
It provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What is the maximum phase-to-phase voltage rating?
The maximum phase-to-phase voltage rating is 36.6kV.
What standard does the 756LR elbow meet?
The 756LR elbow meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand voltage (BIL) rating?
The impulse withstand (BIL) rating is 150kV.
What is the continuous current rating of the elbow?
The elbow has a continuous current rating of 600 Amps.
What is the maximum operating phase-to-ground voltage?
The maximum phase-to-ground operating voltage is 21.1kV.
What cable insulation diameters does the 756LR support?
It supports cable insulation diameters ranging from 0.760 inches to 2.120 inches.
What conductor sizes are compatible with the 756LR?
It is compatible with #2 AWG to 1250 kcmil aluminum and copper conductors.
What voltage class is the 756LR elbow rated for?
The 756LR elbow is rated for use through 35kV.
Is the 756LR elbow submersible?
Yes, it features a fully shielded, fully submersible molded rubber housing.
How to Install 756LR/776LR Deadbreak Elbow Connectors
A comprehensive guide for the safe and proper installation of 756LR and 776LR Deadbreak Elbow Connectors on 35kV class systems, including cable preparation, lug crimping, and connection to mating apparatus.
Estimated time: 1h 30m
Tools needed:
Cable preparation tools (e.g., wire strippers, utility knife), Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device
Supplies needed:
756LR or 776LR Deadbreak Elbow Connector Kit, Lubricant, No. 14 AWG Copper wire (or equivalent), Suitable ground connector, HV insulated cap(s) or connector(s) (if needed), Silicone lubricant, Waterproofing material (for cable jacket)
- Ensure Safety and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. Inspect all parts for damage, rating, and compatibility with mating parts. Ensure the package contents are complete and undamaged.
- Prepare Cable Position and Jacket
Position the cable in its final assembled location, ensuring enough slack to allow for elbow removal. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24” (610mm).
- Perform Cable End Preparation
Follow the specific instructions for your cable type (UNISHIELD*, LEAD SHEATH, JACKETED, or NON-JACKETED) to remove the outer jacket and prepare the cable as shown in the diagrams, creating the specified lengths for insulation, semi-con shield, and tape markers. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back.
- Install and Position Cable Adapter
Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Trim Conductor to Specified Length
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8” to 4-3/4” (111mm-121mm); otherwise, redo the assembly.
- Crimp Compression Lug to Conductor
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping (must be less than 7” (178mm)). Crimp the compression lug according to its supplied instructions. After crimping, wipe all excess inhibitor from the lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter should be between 6-7/8” to 7-5/8” (175mm-194mm); otherwise, redo the assembly.
- Mount Elbow onto Cable Assembly
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.
- Clean and Lubricate Mating Parts
WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove any protective shipping caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.
- Secure Elbow to First Mating Part
Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.
- Attach Second Mating Part
Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions.
- Install Voltage Detection Cap
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage; follow voltage test directions.
- Ground Cable Shield and Waterproof Jacket
Insert one end of a wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Verify De-energized State Using Test Point
CAUTION: When constructing 600amp L-Kits, tighten each component to specified torque per plug connector instructions. If the connector has an integral capacitance test point, remove the test point cap with a hotstick by peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points. Contamination or incorrect equipment can give a false 'no voltage' indication. Treat the elbow as energized until 'no voltage' is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.