ABB - Installation Products 69TCJS1RA46PNNNNNN - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
ABB - Installation Products

69TCJS1RA46PNNNNNN

UPC: 783786197323


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 69TCJS1RA46PNNNNNN is a 69 kV transmission cable joint engineered for demanding high-voltage applications. This specific model features a shieldbreak housing type, designated as Housing Style 1. The housing is designed with a bore diameter of 1.930 inches at the critical transition point between the cable jacket and insulation. This precise bore accommodates a conductor diameter range of 1.328 to 1.377 inches, which translates to 33.73 to 34.98 millimeters. The connector type for this joint is aluminum, and importantly, no separate connector is required, as indicated by Connector Code 46P. The design of this transmission cable joint also signifies that a heatsink is not required, with the Heatsink Size and Heatsink Bore both designated as 'N' for not required. Furthermore, this joint does not necessitate a Type Shield, a Metallic Screen Continuity Kit, an Armor Kit, or an Outer Jacket Restoration Kit, all of which are also designated as 'N' for not required. This configuration streamlines the installation process by omitting components that are not essential for its intended application. The joint is specifically suited for transmission cable systems where these additional kits are not part of the system requirements.
  • 69 kV rated transmission cable joint for high-voltage applications
  • Shieldbreak housing Type 1 with 1.930" bore diameter at jacket/insulation transition
  • Accommodates conductor diameters from 1.328–1.377 inches (33.73–34.98 mm)
  • Aluminum connector (Code 46P) eliminates need for additional connectors
  • No metallic screen continuity, armor, or jacket restoration kits required

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
1.328 to 1.377 in
Connection
Compression
Connection Type
Aluminum/no connector required
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
Housing Size R - Bore Diameter at Jacket/Insulation Transition 1.930 inch, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm)
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
24.0000 L
Package Weight (Metric)
10.8860 kg
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1RA46PVEJNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/No connector Requiered, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size/Bore - V - 2.046 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - J - 4/0 Bonding Cable 4 foot quantity 3 without split bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1R242PNLNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1R140PVBNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-30.70mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q233PRCBNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-30.70mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum/no connector required, Connector Code 38P - Conductor Diameter Range - .9336-1.011 inch (23.77-25.68mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - N - Unknown, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

69TCJS1QA38PNNNNN

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum/no connector required, Connector Code 38P - Conductor Diameter Range - .9336-1.011 inch (23.77-25.68mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - N - Unknown, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q - Bore Diameter 1.750 inch, Insulation Range 1.995-2.300 inch, Connector Type - Copper, Conductor Code 405, Heatsink Size and Bore not Required, Type Shield L - Lead and Neutral Wires, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

69TCJS1Q2405NLNNB

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q - Bore Diameter 1.750 inch, Insulation Range 1.995-2.300 inch, Connector Type - Copper, Conductor Code 405, Heatsink Size and Bore not Required, Type Shield L - Lead and Neutral Wires, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Bore - T - 1.859 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q236PTCBNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Bore - T - 1.859 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 33P. P U C B N B

69TCJS1Q233P36PUCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 33P. P U C B N B

Frequently Asked Questions

Is a heatsink required for this joint?

No, a heatsink is not required (Size N).

What is the operating voltage of this cable joint?

This cable joint is rated for 69 kV transmission applications.

What conductor diameter range does this joint support?

The joint accommodates conductor diameters between 1.328–1.377 inches (33.73–34.98 mm).

Is a metallic screen continuity kit required?

No, a metallic screen continuity kit is not required for this joint.

What type of connector is used in this joint?

The joint uses an aluminum connector (Connector Code 46P) and does not require additional connectors.

Is an armor kit included with this cable joint?

No, an armor kit is not included or required for this joint.

What is the housing style of this cable joint?

The housing style is Type 1, classified as shieldbreak.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.