ABB - Installation Products 376LR-L5250 - 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products 376LR-L5250 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 783786316175


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 376LR-L5250 Loadbreak Elbow Connector is a fully rated 35kV, 200 Amp Class loadbreak connector designed for medium-voltage underground distribution systems, substations, and industrial power connections. This connector accommodates cable insulation diameters from 1.180 inches to 1.465 inches (31.37 mm to 37.21 mm), ensuring compatibility with compressed stranded conductors ranging from 2/0 AWG to 3/0 AWG (67.43 mm²). The connector features a bi-metal compression lug with a universal aluminum barrel, suitable for both copper and aluminum conductors, providing a secure and corrosion-resistant electrical termination. Constructed with a fully shielded, fully submersible molded rubber housing made from 100% peroxide-cured EPDM materials, the 376LR-L5250 offers superior insulation and environmental resistance. The housing includes provisions for hot stick operation, enabling safe loadmaking and loadbreak operations without de-energizing the system. An integral non-corrosive capacitive voltage test point allows for easy and safe testing of circuit integrity during maintenance, enhancing operational safety and reducing downtime. Key specifications include a maximum phase-to-ground operating voltage of 21.1kV, phase-to-phase voltage of 36.6kV, and a basic impulse insulation level (BIL) of 150kV. The connector meets ANSI/IEEE Standard 386 and supports a continuous current rating of 200 Amps with a momentary fault close rating of 10kA symmetrical for 10 cycles. The design includes a long bi-metal compression lug for robust electrical connection and a wide cable range with only four elbow sizes to simplify inventory and installation. Applications include underground distribution systems, substations, and industrial power connections where reliable loadbreak capabilities are essential. The 376LR-L5250 is part of the Elastimold® 376LR series, a trusted solution for connecting and disconnecting 35kV Class, 200 Amp distribution apparatus. Each kit includes the elbow connector housing, bi-metal compression lug, probe, probe wrench, lubricant tube, installation instructions, and crimp chart for streamlined installation and maintenance.
  • 200 Amp, 35kV Class loadbreak connector for medium-voltage applications
  • Accommodates cable insulation diameters from 1.180" to 1.465" (31.37 mm to 37.21 mm)
  • Bi-metal compression lug suitable for copper or aluminum conductors (2/0 AWG to 3/0 AWG)
  • Integrated non-corrosive capacitive voltage test point for safe circuit testing
  • Fully shielded, submersible molded rubber housing with hot stick operation provisions

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
EPDM Rubber, Bi-Metal
Material
Housing - EPDM-Rubber
Series
376LR-L
Size
Cable Insulation Diameter 1.180 inch to 1.465 inch
Size
1.180-1.465 inch cable insulation diameter
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.1000 L
Package Weight (Metric)
1.4060 kg
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

167RLR-G-5240-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

167RLR-F-5210

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167LRT-J-5270

15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167LRT-G-5270

15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15kV, Loadbreak Direct Test Repair Elbow Connector, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

167DELR-7495-5240

200 Amp, 15kV, Loadbreak Direct Test Repair Elbow Connector, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

375LR-H-5240-S

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

375LR-J5260

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

Frequently Asked Questions

What conductors are compatible with the copper compression lug?

The copper compression lug is suitable for all copper conductors only.

What conductors are compatible with the bi-metal compression lug?

The bi-metal compression lug with a universal aluminum barrel is suitable for both copper and aluminum conductors.

Which industry standard does the 376LR elbow meet?

The 376LR elbow meets ANSI/IEEE Standard 386, Latest Revision.

Does the 376LR elbow have a voltage test point?

Yes, the 376LR is equipped with an integral, non-corrosive capacitive voltage test point.

Can the 376LR elbow be operated with a hot stick?

Yes, the 376LR elbow includes provisions for energized operation using standard hot stick tools for loadmaking/loadbreak operation and visible disconnect.

What cable insulation diameters are compatible with the 376LR?

The 376LR elbow connects to cables with insulation diameters from .850 inches (21.6mm) to 1.465 inches (37.2mm).

What is the maximum operating voltage for the 376LR elbow?

The maximum operating voltage for the 376LR elbow is 21.1kV Phase-to-Ground and 36.6kV Phase-to-Phase.

What are the voltage and current ratings of the 376LR elbow?

The 376LR Loadbreak Elbow is rated for 35kV voltage class and 200 Amp continuous and loadbreak current.

What cable insulation diameters are compatible with the 376LR?

The 376LR elbow connects to cables with insulation diameters from .850 inches (21.6mm) to 1.465 inches (37.2mm).

What conductors are compatible with the bi-metal compression lug?

The bi-metal compression lug with a universal aluminum barrel is suitable for both copper and aluminum conductors.

How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial connection of Elastimold 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors to UD cable and 35kV class bushings. For 376LR models, ensure the test point cap is lubricated and assembled tightly.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Crimp tool, Wire brush, Cable cut-back template, Hotstick, Wire strippers, Pliers, Appropriate grounding connector tool

Supplies needed:

Elastimold 375LR or 376LR Loadbreak Elbow Connector kit, Lubricant (supplied with kit, do not substitute), UD cable, No. 14 AWG (2.5mm) copper wire, Grounding connector, HV insulated cap(s) or connector(s) (if shipping covers are present), Silicone grease (for 376LR test point cap)

  1. De-energize and Inspect Components

    DANGER: Ensure all apparatus is de-energized before beginning installation to prevent serious or fatal injury. Inspect all components of the elbow connector kit for completeness, damage, and compatibility with the cable and mating bushing. Verify the probe threads freely into the compression lug for approximately four turns without resistance; replace damaged components if resistance is encountered.

  2. Train and Prepare Cable

    Train the UD cable to ease future operation, ensuring at least 20 inches of excess cable beyond the end of the bushing pad mount transformer. Squarely cut the excess cable at the bushing's center line. Unwrap and bind the concentric neutral wires 8-1/2 inches back from the cable end. Using a cable cut-back template, remove the insulation shield and insulation from the cable end, taking care not to nick the conductor. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all conductive residue.

  3. Install Compression Lug

    Wire brush the bare aluminum conductors immediately before installation. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  4. Assemble Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a probe wrench until the wrench bends.

  5. Connect Concentric Neutral

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, being careful not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for future elbow operation.

  6. Connect Elbow to Bushing (De-energized)

    DANGER: Ensure the transformer and mating bushing are known to be de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. With firm footing and positive control, insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.