ABB - Installation Products 167RLR-F-5210 - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

ABB Installation Products 167RLR-F-5210 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable…

UPC: 783786632374


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 167RLR-F-5210 is a 200 Amp, 15kV loadbreak replacement elbow connector designed for medium-voltage cable systems. This bi-metal compression lug connector accommodates cable insulation diameters between 0.640 inch and 0.820 inch, making it compatible with AWG compressed stranded #3 or solid #2 conductors, as well as 26.67 square millimeter conductors. The elbow connector is engineered for safe and reliable loadbreak operations in underground distribution networks, switchgear, and pad-mounted transformers. Its compression-style termination ensures low-resistance connections, reducing heat buildup and improving system efficiency. The absence of a test point simplifies installation while maintaining compliance with ANSI C119.4 and IEEE 386 standards for loadbreak separable connectors. This connector is ideal for utility companies, industrial facilities, and commercial installations requiring medium-voltage cable terminations. The bi-metal construction provides corrosion resistance and long-term reliability in harsh environments. Installation requires standard compression tools and follows ABB’s documented procedures for proper torque and crimp specifications.
  • 200 Amp, 15kV rated loadbreak replacement elbow connector
  • Cable insulation compatibility: 0.640 inch to 0.820 inch diameter
  • Bi-metal compression lug for AWG #3/#2 or 26.67mm² conductors
  • No test point design for simplified installation
  • Compliant with ANSI C119.4 and IEEE 386 standards

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
#3 STR/COMPR AWG , #2 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.2800 L
Package Weight (Metric)
1.9410 kg
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug

162LR-C5210

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167LRT-J-5270

15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167LRT-G-5270

15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15kV, Loadbreak Direct Test Repair Elbow Connector, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.

167DELR-7495-5240

200 Amp, 15kV, Loadbreak Direct Test Repair Elbow Connector, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

375LR-H-5240-S

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

375LR-J5260

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-K-5270

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

375LR-K-5250-S

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

Frequently Asked Questions

What is the catalog number for the test point cap?

The catalog number for the test point cap is 156-7.

Where are Elastimold 200 A elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.

What is the cable insulation diameter range for 167RLR products with 'F' symbol?

For 167/168RLR products with the 'F' symbol, the cable insulation diameter range is 0.640 inches to 0.820 inches.

What industry standards do these connectors meet?

These connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

What voltage classes are available for these connectors?

These loadbreak repair and replacement elbow connectors are available for 15 kV and 25 kV voltage classes.

What is the extended length of the replacement elbow?

The replacement elbow provides a net gain of 8 7⁄8 inches in length compared to a standard elbow.

What is the extended length of the repair elbow?

The repair elbow provides a net gain of 3 1⁄4 inches in length compared to a standard elbow.

What is the primary purpose of these elbow connectors?

These connectors help transition from live-front to dead-front equipment, eliminating the need for splicing or pulling new cable when existing lengths are too short or bushing heights vary.

What is the extended length of the repair elbow?

The repair elbow provides a net gain of 3 1⁄4 inches in length compared to a standard elbow.

What is the cable insulation diameter range for 167RLR products with 'F' symbol?

For 167/168RLR products with the 'F' symbol, the cable insulation diameter range is 0.640 inches to 0.820 inches.

How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of Elastimold 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cable.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimping tool, Cable cutting tool, Cable insulation removal tool, Screwdriver, Hotstick

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with product), Hose Clamp, No. 14 AWG (2.5mm) Copper Wire, Appropriate Ground Connector, HV Insulated Cap(s) or Connector(s)

  1. Pre-Installation Checks and Safety

    Before starting, ensure all apparatus is de-energized. Inspect the package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; if resistance is met, check for damage. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. DANGER: All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Remove Livefront Termination

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Carefully remove the terminator housing from the cable.

  3. Prepare the Cable for Termination

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to a length of 10-1/2 inches from the bushing centerline. Verify the insulation shield measures less than 6-1/2 inches; if it is greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end, ensuring the cut is square and the conductor is not nicked.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug onto the conductor, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Housing and Probe

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Keep the insulation clean and avoid introducing excess grease into the gap between the lug and insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  6. Connect the Concentric Neutral and Hose Clamp

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. Add the hose clamp as shown in the product diagram and tighten it snugly, but do not overtighten.

  7. Prepare for Connection to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Once lubricated, the elbow is ready for connection to the bushing plug using a hotstick as per the operating instructions. Do not attempt to operate by hand. DANGER: Loadbreak connectors must be operated with a full insulated 'hotstick' type live-line tool. Consult company safe work practices for the required live-line tool length.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.