ABB Installation Products 167RLR-G-5240-S 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable…
UPC: 783786386802
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15kV rated loadbreak elbow connector
- Compatible with cable insulation diameters 0.760" to 0.950"
- Includes 200ECS jacket seal for environmental protection
- Designed for medium-voltage distribution systems (no test point)
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.0000 L |
Package Weight (Metric) | 0.9070 kg |

162LR-B-2240
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
167RLR-F-5210
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
167LRT-J-5270
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
167LRT-G-5270
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
167DELR-7495-5240
200 Amp, 15kV, Loadbreak Direct Test Repair Elbow Connector, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49.
375LR-H-5240-S
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
375LR-J5260
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
375LR-K-5270
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.Frequently Asked Questions
What material is the elbow constructed from?
The elbow is constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
What is the primary function of this elbow connector?
The Elastimold 200 A loadbreak replacement elbow connects to new dead-front equipment when existing cable lengths are too short, eliminating the need for splicing or new cable.
What is the voltage class of the 167RLR elbow?
The 167RLR replacement elbow connector is designed for a 15 kV voltage class.
What is the amperage rating of this product?
This is a 200 A loadbreak elbow connector.
How much length does the replacement elbow add?
The replacement elbow provides a net gain of 8 7⁄8 inches in length, helping to compensate for short existing cables or varying bushing heights.
What cable insulation diameter does the 'G' symbol accommodate?
For the 'G' symbol, the elbow accommodates cable insulation diameters between 0.760 inches and 0.950 inches.
Does the 167RLR-S include a jacket seal?
Yes, the "-S" suffix indicates that the 200ECS jacket seal is included with the 167RLR replacement elbow, which is highly recommended.
Is this product compliant with industry standards?
Yes, the Elastimold 200 A loadbreak repair and replacement elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
Where are Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.
What type of contact is included with the 167RLR?
The 167RLR replacement elbow includes a long bi-metal contact, catalog number 00400X.
How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors
This guide provides step-by-step instructions for installing the 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, converting a livefront termination to deadfront for UD cable.
Estimated time: 2h
Tools needed:
Cable cutter, Wire strippers, Wire brush, Crimp tool, Probe wrench, Full insulated 'hotstick' type live-line tool, Suitable voltage sensing device (for 168RLR), Screwdriver
Supplies needed:
167RLR/168RLR Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Hose Clamp, No. 14 AWG (2.5mm) copper wire, Appropriate ground connector, Silicone grease (for 168RLR test point cap)
- Prepare for Installation and Ensure Safety
Before beginning, ensure all apparatus is de-energized. Read the entire installation instructions. Check the package contents for completeness and damage, and verify all components fit the cable and mating products. Have all required tools ready and maintain cleanliness throughout the procedure. DANGER: All apparatus must be de-energized during installation or removal of part(s). Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Remove Existing Livefront Termination
Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator, then remove the entire terminator housing from the cable.
- Prepare Cable for Elbow Connector
Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. Remove 1-3/8 inches of cable insulation from the end, ensuring the cut is square and the conductor is not nicked. If the insulation shield measures less than 6-1/2 inches, proceed; otherwise, consult an ELASTIMOLD representative.
- Install and Crimp the Compression Lug
Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp as per the crimp chart. Carefully wipe any excessive inhibitor from the lug and cable.
- Lubricate and Assemble Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Connect Concentric Neutral and Ground
Insert one end of a No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. Add the supplied hose clamp as shown in the diagram and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. This lubrication must ONLY be performed if the transformer and elbow are known to be de-energized. Operate the connection using a full insulated 'hotstick' type live-line tool; DO NOT OPERATE BY HAND. Ensure the area is clear of obstructions. Place the elbow connector receptacle over the bushing plug, inserting the elbow male contact until slight resistance is felt, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock.
- Test Voltage on 168RLR (Optional)
If using the 168RLR with a test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it tightly on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.