Overview
- 200 Amp, 35kV rated loadbreak elbow connector for underground distribution
- Accommodates cable insulation diameters from 0.850 inch to 1.050 inch
- Bi-metal compression lug supports AWG Compressed Stranded 1/0, Solid 2/0, and 53.49 mm² conductors
- Integrated test point enables safe voltage verification without service interruption
- Includes 200ECS Jacket Seal for environmental protection and strain relief
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Push-In |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | EPDM, Bi-Metal |
Material | Housing - EPDM-Rubber |
Series | 376LR |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

375LR-H5240
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
274RLR-J-5270
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .980 inch - 1.880 Inch Cable Insulation Diameter, 4/0 Stranded or 250 kcmil Solid Wire Size, Bi-Metal Compression Lug.
274ELR-K5240
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
376LR-K-5270-S
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
167RLR-G-5250-S
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
167RLR-H-5250
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
274RLR-H-5220
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.Frequently Asked Questions
What is the voltage rating of the 376LR elbow?
The 376LR elbow connector is rated for 35kV voltage class, with a maximum phase-to-ground operating voltage of 21.1kV and phase-to-phase of 36.6kV.
Does the connector have a test point?
Yes, the 376LR is equipped with an integral, non-corrosive capacitive voltage test point.
What is the DC fifteen-minute withstand rating?
The DC fifteen-minute withstand rating for the connector is 103kV.
What is the AC one-minute withstand rating?
The AC one-minute withstand rating for the connector is 50kV.
What is the impulse withstand rating (BIL)?
The impulse withstand (BIL) rating is 150kV (1.2 x 50 microsecond wave).
What is included in the 376LR kit?
Each kit contains an elbow connector housing, a bi-metal compression lug, a probe, a probe wrench, a tube of lubricant, installation instructions, and a crimp chart.
Can the 376LR be operated with a hot stick?
Yes, it has provisions for hot stick operation, allowing energized loadmaking/loadbreak operations and a visible disconnect.
Is the 376LR elbow submersible?
Yes, the 376LR elbow features a fully shielded and fully submersible molded rubber housing.
What standards does the 376LR connector meet?
The 376LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.
What type of lug is included with the connector?
A long bi-metal compression lug is standard, which is suitable for both copper and aluminum conductors.
How to Install 375LR/376LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for installing Elastimold 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors, designed to terminate UD cable and connect to 35kV class loadbreak bushings. Ensure all apparatus is de-energized before beginning installation.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Crimp tool, Wire brush, Hotstick
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), No. 14 AWG (2.5mm) Copper Wire, Appropriate Grounding Connector
- Perform Pre-Installation Checks
Check the package contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; if resistance is encountered prior to full assembly, check for damage and replace the damaged component. Read the entire installation instructions before starting. Have all required tools at hand and maintain cleanliness throughout the procedure. Ensure all apparatus is de-energized before beginning installation.
- Train the Cable
Train the UD cable as shown in the documentation to ease future operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.
- Prepare the Cable for Termination
Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied; DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten with the probe wrench until the wrench bends.
- Connect the Concentric Neutral
Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect the Elbow to the Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control of the elbow connector, insert the probe tip approximately 2 inches into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.