ABB - Installation Products 274ELR-K5240 - 200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 274ELR-K5240 200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has…

UPC: 783786461073


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274ELR-K5240 Loadbreak Repair Elbow Connector is a high-capacity, medium-voltage solution designed for reliable cable repair in distribution systems. Rated at 200 Amps and 25kV, this elbow connector accommodates cable insulation diameters from 1.090 to 1.310 inches, making it suitable for 1/0 and 2/0 AWG compressed stranded or solid conductors (53.49 mm²). The extended length contact and elbow housing provide a net gain of 3-1/4 inches, enhancing installation flexibility and reducing stress on cable terminations. Equipped with a test point for safe voltage verification, this connector ensures compliance with loadbreak switching requirements while maintaining operational continuity. The included 02509X Bi-Metal Contact ensures compatibility with both copper and aluminum conductors, reducing the need for additional components. Ideal for utility, industrial, and commercial applications where medium-voltage cable repairs are frequent, this repair elbow minimizes downtime by enabling quick, field-replaceable solutions without full cable replacement.
  • 200 Amp, 25kV rated loadbreak repair elbow connector
  • Extended length contact and housing for 3-1/4 inch net gain
  • Test point for safe voltage verification
  • Supports cable insulation diameters 1.090 to 1.310 inches
  • Compatible with 1/0 and 2/0 AWG compressed stranded or solid conductors (53.49 mm²)

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 25kV Class, 125kV BIL apparatus
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Length
11.71 in
Length
297.434 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 3-1/4 inch (82.6mm). Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Repair Elbow Connector with Test Point
Voltage Rating
25 kV
Width
8.4 in
Width
213.36 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.5000 L
Package Weight (Metric)
1.5880 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .805-1.060 inch Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-C5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .805-1.060 inch Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

376LR-K-5270-S

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

167RLR-G-5250-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

167RLR-H-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

274RLR-H-5220

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Replacement Elbow Connector

167RLR-K5270

15kV 200 Amp, Loadbreak Replacement Elbow Connector
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-L5250

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

167RLR-G-5240-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

Frequently Asked Questions

What is the voltage rating of the 274ELR-K5240?

The connector is rated for 25kV operation.

What cable insulation diameters does this connector support?

The connector supports cable insulation diameters from 1.090 to 1.310 inches.

What conductor sizes are compatible with this elbow connector?

The connector is compatible with 1/0 and 2/0 AWG compressed stranded or solid conductors (53.49 mm²).

Does this connector include a test point?

Yes, the connector includes a test point for safe voltage verification.

What is the net length gain provided by the extended housing?

The extended length contact and elbow housing result in a net gain of 3-1/4 inches.

What type of contact is included with the 274ELR-K5240?

The connector includes a 02509X long Bi-Metal Contact for compatibility with both copper and aluminum conductors.

How to Install 273ELR/274ELR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the new installation and total replacement of 273ELR (without test point) and 274ELR (with test point) Loadbreak Elbow Connectors, including cable preparation, assembly, and connection procedures.

Estimated time: 1h 30m

Tools needed:

Pin wrench, Wire brush, Crimp tool, Hotstick, Suitable voltage sensing device (for 274ELR)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector, Silicone grease (for 274ELR test point cap)

  1. Perform Initial Safety Checks and Prepare Components

    DANGER: Ensure all apparatus is de-energized before starting installation or removal of parts, except for test point caps and indicators that can be installed and operated energized. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check compression lug threads by hand-threading the probe; replace if resistance is encountered prior to full assembly. Gather all required tools and maintain a clean work area.

  2. Train and Prepare the Cable

    Train the cable to allow for ease of operation, ensuring a minimum of 20 inches extends beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 'X' inches back from the cable end (e.g., 13 inches for 02200XXX, 02500XXX, 02509XXX). Carefully remove the insulation shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush the bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor and ensure the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off any excessive inhibitor. Remove the remaining insulation shield as shown in the diagram and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; DO NOT SUBSTITUTE. Other lubricants may be harmful to this product or its mating product(s). Keep the insulation free of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, being careful not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  4. Connect the Concentric Neutral Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist it tightly, ensuring not to damage the eye. Twist all concentric neutral wires together with the copper wire from the grounding eye. Connect this twisted bundle to ground using an appropriate connector, providing adequate slack in the wires to allow for elbow operation.

  5. Connect the Elbow to the Bushing Plug

    CAUTION: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY if it is confirmed that both the transformer and elbow are de-energized. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until slight resistance is felt (when the arc follower meets the female contact). DO NOT HOLD IN THIS POSITION BUT IMMEDIATELY push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to ensure the internal lock engages.

  6. Perform Voltage Test (274ELR only)

    DANGER: The voltage test point is a capacitance device; it is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter that is used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, etc. around the test point or use of the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. If using a 274ELR with a test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. After voltage detection, clean and lubricate the inside surface of the test point cap with silicone grease and replace it securely on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.