Authorized ABB Distributor (Installation Products)
ABB - Installation Products 167RLR-G-5250-S - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

ABB Installation Products 167RLR-G-5250-S 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable…

UPC: 783786386789


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167RLR-G-5250-S is a 200 Amp, 15kV loadbreak replacement elbow connector engineered for medium-voltage cable systems requiring safe, reliable disconnection under load. This connector is designed to accommodate cable insulation diameters from 0.760 inch to 0.950 inch, making it compatible with a wide range of industrial cables. The bi-metal compression lug ensures reliable electrical contact and mechanical integrity, supporting compressed stranded conductors in sizes 2/0 and 3/0 AWG or solid conductors up to 67.43 mm². Key applications include repair of failed elbow connections where cable must be restripped and a new compression lug applied, or when cables have been accidentally trimmed too short. The extended design provides extra length for connecting new apparatus to existing cables without replacing the entire cable run. This elbow connector is fully rated for 15kV Class, 95kV BIL apparatus, meeting ANSI/IEEE Standard 386 requirements. The 167RLR-G-5250-S features a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation for long-term reliability. It includes a 200ECS jacket seal for environmental protection and moisture resistance. The connector is designed for hot stick operation and includes provisions for ground wire connection, enhancing safety during installation and maintenance. With a continuous and loadbreak rating of 200 Amps and a momentary fault close rating of 10kA symmetrical for 10 cycles, this elbow connector delivers robust performance in utility, industrial, and commercial power distribution systems.
  • 200 Amp, 15kV Class loadbreak elbow connector
  • Accommodates cable insulation diameters from 0.760" to 0.950"
  • Bi-metal compression lug compatible with 2/0-3/0 AWG compressed stranded or 67.43 mm² solid conductors
  • Fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation
  • Includes 200ECS jacket seal for environmental protection and moisture resistance

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection Type
Loadbreak Replacement Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
167RLR
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.0000 L
Package Weight (Metric)
0.9070 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

167RLR-H-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

274RLR-H-5220

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Replacement Elbow Connector

167RLR-K5270

15kV 200 Amp, Loadbreak Replacement Elbow Connector
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-L5250

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

167RLR-G-5240-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

167RLR-F-5210

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

167LRT-J-5270

15KV, 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Frequently Asked Questions

Is a jacket seal included with this connector?

Yes, the 200ECS jacket seal is included for environmental protection.

What is the current rating of this connector?

The connector has a current rating of 200 Amps.

What is the voltage rating of this connector?

The connector is rated for 15kV medium-voltage applications.

What cable insulation diameter range does this connector fit?

The connector fits cable insulation diameters from 0.760 inch to 0.950 inch.

What conductor sizes does this connector support?

It supports 2/0 and 3/0 AWG compressed stranded conductors or 67.43 mm² solid conductors.

Is this connector suitable for loadbreak applications?

Yes, it is designed for loadbreak applications, allowing safe disconnection under load.

How to Install Elastimold 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for safely installing Elastimold 167RLR and 168RLR loadbreak replacement elbow connectors, converting livefront terminations to deadfront for UD cables.

Estimated time: 1h

Tools needed:

Wire brush, Crimping tool, Probe wrench, Wire strippers, Hotstick (for operation)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Hose Clamp, No. 14 AWG (2.5mm) Copper Wire, Appropriate Ground Connector

  1. De-energize and Remove Existing Livefront Termination

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts to prevent serious or fatal injury. Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator, then disconnect the ground lead from its base. Finally, remove the terminator housing from the cable.

  2. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches (26.7 cm) from the bushing centerline. Verify the insulation shield length; if it's less than 6-1/2 inches (16.5 cm), proceed. If greater, consult an ELASTIMOLD representative. Carefully remove 1-3/8 inches (3.5 cm) of cable insulation from the end, ensuring a square cut and avoiding nicks to the conductor.

  3. Install and Crimp the Compression Lug

    Wire brush the bare aluminum conductor immediately. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the lug and cable.

  4. Assemble the Elbow Connector Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.

  5. Connect the Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation. Add the supplied hose clamp and tighten it snugly, but do not overtighten.

  6. Lubricate and Prepare for Bushing Connection

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. The elbow is now ready for connection to the bushing plug, which must be done using a full insulated hotstick as per operating instructions, not by hand.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.