ABB - Installation Products 375LR-J5240-S - 35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. With Sealing Kit

ABB Installation Products 375LR-J5240-S 35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…

UPC: 075114257992


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35kV 200 Amp Loadbreak Elbow Connector, SKU 375LR-J5240-S, is engineered for reliable medium-voltage power distribution. This connector is designed for loadbreak-capable connections in underground and overhead systems, facilitating safe connection and disconnection under load. It accommodates cable insulation diameters ranging from 0.980 inches to 1.180 inches, aligning with common 35kV cable specifications. The integrated bi-metal compression lug is suitable for both stranded copper conductors (1/0 AWG) and solid aluminum conductors (2/0 AWG), with a compressed cross-sectional area of 53.49 mm². This specific model does not include a test point, simplifying installation for applications where direct testing is not a requirement. A sealing kit is included to provide environmental protection against moisture and contaminants, ensuring long-term operational integrity. This connector is part of ABB's 375LR series, optimized for medium-voltage distribution applications. Typical use cases include utility substations, industrial power distribution networks, and commercial electrical infrastructure requiring secure, high-voltage connections. The bi-metal construction offers versatility, supporting both copper and aluminum conductors without the need for additional adapters. This loadbreak elbow connector is crucial for minimizing downtime during system maintenance or reconfiguration.
  • 35kV voltage rating, 200 Amp continuous current capacity
  • Accommodates cable insulation diameters from 0.980 to 1.180 inches
  • Bi-metal compression lug for 1/0 AWG stranded copper or 2/0 AWG solid aluminum conductors (53.49 mm² compressed)
  • Loadbreak-capable design for safe connection/disconnection under load
  • Includes sealing kit for environmental protection; no test point

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
LoadBreak Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
375LR
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-K-5240

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. With Sealing Kit

375LR-J5250-SG3

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. With Sealing Kit
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-H-2240

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

376LR-H-5240-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .980 inch - 1.880 Inch Cable Insulation Diameter, 4/0 Stranded or 250 kcmil Solid Wire Size, Bi-Metal Compression Lug.

274RLR-J-5270

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. .980 inch - 1.880 Inch Cable Insulation Diameter, 4/0 Stranded or 250 kcmil Solid Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274ELR-K5240

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

376LR-K-5270-S

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

Frequently Asked Questions

Can the bushing inserts operate when fully submerged?

Yes, Elastimold 200 amp bushing inserts are designed to ensure exceptional performance, even when fully submerged.

Are Elastimold products compatible with existing systems?

Yes, they can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or additional elbows in existing systems.

What is the benefit of the vented ring design?

The patented vented ring design, for 25 kV and 35 kV classes, prevents partial vacuum flashover during switching operations.

How does the PBT interface shield indicate voltage class?

The PBT interface shield is color-coded: red for 15 kV, blue for 25 kV, and black for 35 kV class.

What voltage classes do the bushing inserts support?

The Elastimold 200 amp bushing inserts support 15 kV, 25 kV, and 35 kV system voltages.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows support 15 kV and 25 kV system voltages.

How does the PBT interface shield indicate voltage class?

The PBT interface shield is color-coded: red for 15 kV, blue for 25 kV, and black for 35 kV class.

What voltage classes do the bushing inserts support?

The Elastimold 200 amp bushing inserts support 15 kV, 25 kV, and 35 kV system voltages.

What voltage classes do the loadbreak elbows support?

The Elastimold 200 amp loadbreak elbows support 15 kV and 25 kV system voltages.

What is the benefit of the vented ring design?

The patented vented ring design, for 25 kV and 35 kV classes, prevents partial vacuum flashover during switching operations.

How to Install the 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors, including cable preparation, elbow assembly, and connection to a 35kV class loadbreak bushing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Crimp tool, Wire brush, Wire strippers, Hotstick (minimum 8 ft)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector, HV insulated cap(s) or connector(s)

  1. Prepare for Installation and Inspect Components

    Ensure all apparatus are de-energized. Check package contents for completeness and damage. Inspect all components for proper fit with cable and mating products. Verify probe threads by hand-threading into the compression lug. Gather all required tools and maintain cleanliness. If supplied with shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing.

  2. Train and Prepare the Cable

    Train the cable as shown (20” min. beyond end of cable pad mount transformer) for ease of operation. Cut excess cable squarely at the bushing's center line. Unwrap and bind concentric neutral wires 8-1/2” back from the cable end. Remove shield and insulation squarely, taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug per the crimp chart, starting at the mark and rotating 180 degrees for each crimp. Wipe off excess inhibitor. Remove the insulation shield and bevel the insulation end 1/8” max. Thoroughly clean insulation to remove conductive residue.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant only; do not substitute. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.

  4. Connect the Concentric Neutral Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the neutral wires for elbow operation.

  5. Connect the Elbow to the Bushing Plug

    Ensure the transformer and elbow are de-energized. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Withdraw the elbow from the apparatus parking stand (if applicable) with a fast, straight, firm motion, avoiding placement near a ground plane. Insert the probe tip approximately 2” into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock. Do not operate by hand.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.