Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1K1330 - 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.

ABB Installation Products 35PCJ1K1330 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch.…

UPC: 075114311939


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1K1330 35kV Power Cable Joint Style 1 is a fully shielded, fully submersible straight splice designed for permanent cable terminations in medium-voltage power distribution systems. Engineered to IEEE Standard 404, this joint accommodates cable insulation diameters from 1.090 inches to 1.310 inches and supports compressed stranded conductors sized 500 kcmil, solid conductors sized 600 kcmil, or metric conductors sized 250 mm² to 300 mm². The integrated aluminum compression lug ensures reliable electrical conductivity and mechanical integrity under rated conditions. Key electrical ratings include a 200kV BIL impulse withstand (1.2 x 50 microsecond wave), 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. The joint maintains continuous current and short-time current ratings equal to the connected cable, up to 35kA. Its molded conductive shield and housing provide a virtually indestructible ground shield for deadfront construction, eliminating the need for taping during installation. Applications include joining cable runs in new installations or repairing broken cables in existing systems. The pin-and-socket interlock design withstands pulls up to 500 lbs, making it suitable for direct burial or vault installations. The grounding eye allows convenient connection of a ground wire to the molded conductive shield, ensuring proper grounding potential. For use on UD cable with concentric neutral and extruded insulation shielding, or fabric tape shielded/lead-jacketed cables with appropriate adapters. Each kit includes the joint housing and components for a single splice. For enhanced sealing and grounding, optional kits (e.g., 200ECS for neutral wire or 200ECS-G3 for copper line shield) can be added to the product number. Two kits are required for a complete splice.
  • Fully shielded, fully submersible straight splice for 35kV applications
  • Accommodates insulation diameters 1.090"–1.310" and conductors 500–600 kcmil / 250–300 mm²
  • Rated per IEEE Standard 404 with 200kV BIL impulse withstand
  • Molded conductive shield and housing for deadfront construction and grounding
  • Pin-and-socket interlock withstands pulls up to 500 lbs; suitable for direct burial or vaults

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

35PCJ1M1310

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Compressed Stranded 250 /Solid 300.

35PCJ1H1280

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Compressed Stranded 250 /Solid 300.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 500

25PCJ1K1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 500
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

35PCJ1J1300

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1K2270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Solid 350.

15PCJ1H1290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

35PCJ1H1240

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

35PCJ1H1230

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

Frequently Asked Questions

What are the available voltage classes?

The Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What standards do the PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What is the pull force withstand capability?

The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force up to 500 lb.

Do I need to tape the cable entrance?

No, the cable entrance engages the insulation shielding of the cable, eliminating the need for taping.

How do I select connectors for different conductors?

Aluminum compression connectors are for aluminum-to-aluminum or aluminum-to-copper. Copper compression connectors are for copper-to-copper only and should not be used on aluminum.

How are transition joints catalog numbers constructed?

When constructing a catalog number for a transition joint (two different-size cables), list the larger connector first and the smaller connector second.

What is the short-time current rating?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the housing material?

The joints feature permanently crimped connectors inside ethylene propylene diene monomer (EPDM) rubber housings.

What is the continuous current rating?

The continuous current rating of the PCJ power cable joints is equal to that of the cable rating.

What is the maximum conductor size?

The Elastimold PCJ power cable joints can accommodate conductor sizes up to 1250 kcmil.

How to Install the 35PCJ1 Series Cable Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for wire shielded cables.

Tools needed:

Cable cutting tool, Measuring tape, Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Conductor connector (user supplied), DELTECt Cable ties TYD5135 (for 35kV only), #14 AWG copper wire or equivalent (if needed), Appropriate connector (for grounding wires), Cable jacket reconstruction material (if applicable)

  1. Ensure Safety and Prepare Cables

    DANGER: De-energize all apparatus during installation or removal of parts. Confirm all components are compatible and undamaged. Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Cut both cables at the joint centerline.

  2. Prepare Cable 1 and Store Joint Housing

    Taper the edge of Cable 1 insulation from at least 1/2 inch to no greater than 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage.

  3. Prepare Cables for Splice Installation

    Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the specified dimensions (e.g., 2 1/2 inches for 500-750 MCM conductor 'X'). Then, carefully remove the insulation shield from both cables according to the specified dimensions (e.g., 6 1/4 inches for 500-750 MCM conductor 'Y'). WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  4. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the conductor insertion dimension against the 'Max Check Before' table; redo assembly if it exceeds the maximum. Crimp the splice following the manufacturer's recommendations provided with the splice. Wipe off any excess inhibitor. Verify the distance between cable insulations against the 'Max Check After' table; redo assembly if it exceeds the maximum. Remove any sharp protrusions or burrs generated during crimping. Ensure all metal chips/filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to create a lubricant ramp at the edge of the insulation shield.

  5. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge and 1/4 inch (6mm) from the first tie with offset locking heads. Use a T&B WT3D tool to tighten and trim. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.