ABB Installation Products 35PCJ1K2270 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786013869
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV Voltage Rating
- Single-Piece Housing Design
- Cable Insulation Diameter: 1.090" - 1.310"
- Copper Conductor Compatibility: 4/0 AWG Stranded / 250 AWG Solid
- ABB - Installation Products Manufacturer
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 4/0 STR AWG , 250 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

35PCJ1L1270-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cold-Shrinkable Jacket Seal Included.
15PCJ1H1290
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
35PCJ1H1240
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
35PCJ1H1230
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
15PCJ1K1310
15kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum compression lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.
35PCJ1J1240-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cold-Shrinkable Jacket Seal Included.
35PCJ1L1300-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cold-Shrinkable Jacket Seal Included.
35PCJ1P1410-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What are Elastimold PCJ power cable joints used for?
Elastimold PCJ power cable joints are used for straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil. They provide a permanent, fully shielded, and submersible splice.
What type of connector is included in N1 kits?
N1 kits include an aluminum compression connector suitable for splicing aluminum-to-aluminum or aluminum-to-copper conductors.
What safety standards do PCJ power cable joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
Can copper connectors be used on aluminum conductors?
No, copper connectors should NOT be used on aluminum conductors. N2 kits include copper connectors for copper-to-copper connections only.
How do you construct a catalog number for a transition joint?
When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.
What is the BIL impulse withstand for the 35 kV class joint?
For the 35 kV class, the BIL impulse withstand is 300 kV with a 1.2 x 50 μsec. wave.
What pull force can the pin-and-socket interlock withstand?
The pin-and-socket interlock on the PCJ power cable joints is designed to withstand a pull force of up to 500 lb.
What is the short-time current rating for these cable joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating of PCJ cable joints?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What are the two styles of PCJ power cable joints?
Style 1 has a single-piece housing for straight splicing of similar cables. Style 2 includes separate cable adapters for transition splicing between different cable sizes.
How to Install the 35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 35PCJ1 series straight joint for aluminum and/or copper conductor, wire shielded cables. Ensure all safety precautions are followed.
Estimated time: 2h
Tools needed:
Cable cutters, Wire strippers, Wire brush (for aluminum conductors), Crimping tool (for splice and connectors), T&B WT3D tool (for 35kV DELTECt Cable ties)
Supplies needed:
Joint Housing (included in package), Splice (Conductor Contact, included in package), Lubricant (DO NOT SUBSTITUTE, included in package), Appropriate connector (user supplied, for grounding wires), DELTECt Cable ties TYD5135 (for 35kV only), No. 14 AWG copper wire (if shield wires are smaller than #14 AWG)
- Ensure Safety and Inspect Components
DANGER: All apparatus must be de-energized during installation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety. Inspect all package contents for completeness and damage. Verify all components for proper fit with the cable and/or mating products.
- Prepare Cables for Jointing
Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the joint centerline.
- Prepare Cable 1 Insulation and Store Housing
Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, pushing it up to the shield wires for temporary storage.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation from both Cable 1 and Cable 2 to the specified 'X' and 'Y' dimensions (refer to the document's diagram and table for exact measurements). Then, carefully remove the insulation shield from both cables. WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.
- Install and Crimp the Splice
If conductors are aluminum, wire-brush them and immediately insert into the splice. Check the conductor insertion dimension against the 'Max Check Before' table; redo if it exceeds. Crimp the splice following its provided recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; redo if it exceeds. Remove any sharp protrusions or burrs from crimping and clean metal chips/filings from the assembly area. Clean and lubricate cables as indicated, building up lubricant at the insulation shield edge.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring equal deformation of the joint ends. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, 1/4 inch from the edge and 1/4 inch from the first with offset locking heads, using the T&B WT3D tool. Remove and discard the yellow pin from the joint grounding eye. Retrain and secure shield wires to the joint ends. Insert one shield wire from each cable (if #14 AWG or larger) through the joint grounding eye; use separate #14 AWG copper wire if smaller. Connect all grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing where applicable.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.