ABB Installation Products 35PCJ1J1300 35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch.…
UPC: 075114311922
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 35kV systems with 0.980-1.180 inch cable insulation diameter
- Aluminum compression lug for secure electrical and mechanical connection
- Designed for underground and aerial medium-voltage cable installations
- Part of ABB Installation Products catalog for power distribution systems
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 350 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Aluminum |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Size | 0.980 inch to 1.180 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

35PCJ1M1300
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
35PCJ1K2270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ1H1290
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
35PCJ1H1240
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
35PCJ1H1230
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
15PCJ1K1310
15kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum compression lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.
35PCJ1J1240-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cold-Shrinkable Jacket Seal Included.
35PCJ1L1300-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What material are PCJ power cable joints made from?
Elastimold PCJ power cable joints use permanently crimped connectors inside ethylene propylene diene monomer (EPDM) rubber housings.
What type of connector is included in the N1 kit?
The N1 kit includes an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.
What safety standards do PCJ joints meet?
The shield design meets IEEE 592 standard. Connectors meet ANSI 119.4 Class A and Class 3 ratings.
What is the BIL impulse withstand for 35 kV PCJ joints?
For the 35 kV class, the BIL impulse withstand is 300 kV, based on a 1.2 x 50 μsec. wave.
Can copper connectors from N2 kits be used on aluminum conductors?
No, copper compression connectors from N2 kits are for copper-to-copper connections only and should not be used on aluminum conductors.
How do you order a transition joint for different cable sizes?
When ordering a transition joint for two different-size cables, list the larger connector first and the smaller connector second in the catalog number.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What is the short-time current rating of PCJ joints?
The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
Do PCJ joints require taping during installation?
No, the cable entrance of PCJ joints engages the insulation shielding of the cable, eliminating the need for taping.
What are the two styles of PCJ power cable joints?
Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.
How to Install the 35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for installing the 35PCJ1 Series straight joint for wire shielded cables. Ensure all safety precautions are followed for high voltage electrical equipment.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Utility knife, Measuring tape, Wire brush, Crimping tool, T&B WT3D tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector, #14 AWG copper wire (if shield wires are smaller), DELTECt Cable ties (for 35kV only)
- Ensure Safety and Prepare Cables for Length
DANGER: De-energize all apparatus before installation. This product must be installed by competent personnel trained in high voltage electrical safety. Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires and then cut both cables at the joint centerline.
- Prepare Cable 1 and Store Joint Housing
Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires.
- Prepare Cables for Splice and Install Splice
Carefully remove the cable insulation and then the insulation shield from both cables. WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. If conductors are aluminum, wire-brush them immediately before inserting into the splice. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor and remove any sharp protrusions or metal chips from the crimped splice and surrounding area.
- Clean, Lubricate, and Position Joint Housing
Clean the cables where indicated and lubricate them in the direction of the arrows, ensuring a build-up of lubricant at the edge of the insulation shield. Slide the joint housing into its final position. Verify proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.
- Install 35kV Specific Components (If Applicable)
For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the splice edge, then install the second ties approximately 1/4 inch (6mm) from the first, with an offset of the locking heads. Use the recommended T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.
- Complete Grounding and Jacket Reconstruction
Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.