Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1H1280 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Compressed Stranded 250 /Solid 300.

ABB Installation Products 35PCJ1H1280 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 075114311915


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 35kV Power Cable Joint, SKU 35PCJ1H1280, is designed for reliable termination of medium voltage power cables. It features a single-piece housing for straightforward installation and robust protection. The joint is engineered to accommodate cable insulation diameters ranging from 1.090 inches to 1.310 inches, ensuring compatibility with a specific range of cable constructions. This product is suitable for use with aluminum conductors, supporting both compressed stranded AWG 250 and solid AWG 300 conductor sizes. The UNSPSC code for this item is 39121452. ABB's Installation Products division is known for its commitment to electrical infrastructure solutions. This joint provides a secure and insulated connection, critical for maintaining the integrity of power distribution systems. Its design focuses on delivering a dependable splice for 35kV applications where cable insulation diameter falls within the specified range and aluminum conductors of the noted sizes are utilized. The single-piece housing simplifies the assembly process, reducing potential installation errors and time on site.
  • 35kV voltage rating for medium voltage applications
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Designed for aluminum conductors (AWG 250 compressed stranded / 300 solid)
  • ABB Installation Products quality and reliability

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
250 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Size
1.090 inch to 1.310 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 250.

35PCJ1L2280

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 250.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 500

25PCJ1K1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 500
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.

35PCJ1J1300

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 350 /Solid 400 /mmSquared 185.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1K2270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Solid 350.

15PCJ1H1290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

35PCJ1H1240

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

35PCJ1H1230

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
15kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum compression lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

15PCJ1K1310

15kV Power Cable Joint Style 1, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum compression lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

Frequently Asked Questions

What are Elastimold PCJ power cable joints?

They are cable splicing products with permanently crimped connectors inside EPDM rubber housings, offering proven reliability for joining cables. They provide a permanent, fully shielded, and submersible splice.

What is the short-time current rating of PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What type of connector is included for aluminum conductors?

Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum-to-aluminum or aluminum-to-copper conductors.

What is the purpose of Style 2 PCJ joints?

Style 2 PCJ joints include separate cable adapters, allowing for transition splicing between two different cable sizes.

What is the purpose of Style 1 PCJ joints?

Style 1 PCJ joints are designed for straight splicing of two similar cables using a single-piece housing.

What standards do PCJ joint components meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the continuous current rating of PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What are the installation environment options for PCJ joints?

PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications.

What conductor materials are compatible with PCJ joints?

PCJ joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the 15/25/35PCJ1WXXXX Straight Joint

This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1WXXXX straight joint, designed for connecting aluminum to aluminum and/or aluminum to copper wire shielded cables.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife or tapering tool, Wire-brush, Crimping tool, T&B WT3D tool (recommended for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG)

  1. Prepare Cables and Ensure Safety

    DANGER: De-energize all apparatus before starting. Inspect all parts for damage and compatibility. Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires and then cut both cables precisely at the joint's centerline.

  2. Prepare Cable Insulation and Housing

    Taper the edge of Cable 1's insulation shield from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, positioning it up to the shield wires. Then, meticulously remove the cable insulation and the insulation shield from both cables, ensuring no nicks or cuts to the conductor or underlying insulation.

  3. Install and Crimp the Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the dimension against the 'Max Check Before' table; if it exceeds, re-do the assembly. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; if it exceeds, re-do the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area. Clean the cables as indicated and apply lubricant to build a ramp at the edge of the insulation shield.

  4. Complete Joint Assembly and Grounding Connections

    Slide the joint housing into its final position, ensuring proper alignment by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge, with the second tie 1/4 inch (6mm) from the first, offsetting the locking heads. Use the T&B WT3D tool if available. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from each cable (if #14 AWG or larger) through the joint grounding eye. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.