ABB - Installation Products 273RLR-H-5250 - 200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products 273RLR-H-5250 200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow…

UPC: 783786034628


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 273RLR-H-5250 Loadbreak Replacement Elbow Connector is a 200 Amp, 25 kV-rated component designed for reliable medium-voltage power distribution repairs. This repair elbow features an extended length contact and housing, delivering a net gain of 8-7/8 inches to simplify installation in tight spaces or when working with existing cable runs. The integrated 00400X long Bi-Metal Contact ensures durable electrical connections with robust conductivity and corrosion resistance, critical for long-term underground installations. The compression termination design requires appropriate tooling for secure installation, ensuring mechanical integrity and preventing outages in medium-voltage systems. This model is part of ABB Installation Products' 273RLR series, a trusted solution for maintaining and repairing underground distribution systems, substations, and industrial power networks. Its extended length design reduces the need for cable splicing, streamlining repair processes and improving operational efficiency. Verify cable size and conductor gauge compatibility before ordering to ensure optimal performance in your application.
  • 200 Amp, 25 kV loadbreak replacement elbow connector
  • Extended length contact and housing (8-7/8" net gain)
  • Bi-Metal Contact (00400X long) for durable conductivity
  • Cable insulation diameter range: 0.850" to 1.050"

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 25kV Class, 125kV BIL apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection Type
Compression
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Series
273RLR
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

K151SR-D2270

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.890 inch to 1.220 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.

K151SR-C0210

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.

K151SP-B0200

15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid

168ELR-6689-5250

15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

273RLRJ-5270

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5210

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

168RLR-G-5260

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

Frequently Asked Questions

What voltage classes do these elbows support?

These ABB Elastimold loadbreak repair and replacement elbows support 15 kV and 25 kV voltage classes.

How much length does the replacement elbow add?

The replacement elbow provides a net gain of 8 7⁄8 inches in length due to its extended housing and compression lug.

What is the extended length of the repair elbow?

The repair elbow provides a net gain of 3 1⁄4 inches in length.

What is the current rating of these elbow connectors?

The elbow connectors are rated for 200 A loadbreak applications.

What conductor sizes are compatible with 273RLR?

The 273RLR is compatible with conductor sizes from #2 AWG to 250 kcmil, including 1/0, 2/0, 3/0, and 4/0.

What standards do these elbow connectors comply with?

These elbow connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

Where are Elastimold 200 A elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.

What cable insulation diameters does 273RLR accommodate?

The 273RLR accommodates cable insulation diameters ranging from 0.760 inches to 1.310 inches, depending on the specific configuration (G, H, J, K).

What is the catalog number for the test point cap?

The catalog number for the test point cap is 156-7.

What conductor sizes are compatible with 273RLR?

The 273RLR is compatible with conductor sizes from #2 AWG to 250 kcmil, including 1/0, 2/0, 3/0, and 4/0.

How to Install 273RLR/274RLR Loadbreak Replacement Elbow Connectors

This guide details the installation of 273RLR/274RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cables. It covers cable preparation, elbow assembly, and connection to 25kV class loadbreak bushings.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Hotstick

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant, Hose Clamp, Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate ground connector, Silicone grease (for 274RLR test point cap)

  1. Review Safety Warnings and Prepare Components

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Inspect all parts for damage, rating, and compatibility. Check package contents for completeness. Verify proper fit of components with cable and/or mating products. Test probe threads into compression lug. Read all instructions and gather required tools. Maintain cleanliness throughout the procedure.

  2. Remove Existing Livefront Terminator

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Remove the terminator housing from the cable.

  3. Prepare the Cable End

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. Check if the insulation shield measures less than 6-1/2 inches from the cut end; if greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end, cutting squarely. DO NOT NICK THE CONDUCTOR.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor immediately. Install the compression lug onto the conductor. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart (start at the crimp line mark, rotate 180 degrees for each successive crimp). Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants as they may be harmful. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  6. Connect the Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown in the diagram and tighten it snugly. Do not overtighten.

  7. Connect the Elbow to the Bushing Plug (De-energized)

    DANGER: Ensure the transformer and elbow are known to be DE-ENERGIZED before proceeding with lubrication. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. WARNING: DO NOT OPERATE BY HAND. Use a full insulated "hotstick" type live-line tool for this operation. Remove the insulated cap from the bushing by attaching the hotstick tool to the pulling eye and following accessory instructions. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to engage the internal lock.

  8. Perform Voltage Test (274RLR only)

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. WARNING: Contamination, moisture, dirt, or incorrect measuring equipment can provide a false "no voltage" indication. Treat the elbow as energized until confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.