ABB Installation Products 162LR-B5250-SG3 200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905…
UPC: 075114187893
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15kV rated loadbreak elbow connector
- Bi-metal compression lug for copper and aluminum conductors (AWG 2/0 to 3/0 stranded/solid)
- Cable insulation diameter range: 0.635" to 0.905"
- Includes 200ECS-G3 Jacket Seal and Grounding Kit
- Loadbreak capability for safe connection/disconnection under load
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection | Push-In |
Connection Type | LoadBreak Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 162LR |
Size | Cable Insulation Diameter 0.635 inch to 0.905 inch |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-D5250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded, 2/0 Solid Wire Size, Bi-Metal Compression Lug, No Sealing Kit
162LR-B5240-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-B5240(CTN)
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
162LR-B-5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B-5240-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
162LRJS-A5220
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug
162LRJS-B5210
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LRJS-B5220
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector without Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression LugFrequently Asked Questions
What standards and certifications does it meet?
The product is IEEE 386 compliant, has ANSI certification, and Rural Utilities Service (RUS) acceptance.
What certifications does this product have?
It has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What are the voltage ratings for this product?
The loadbreak elbow is available for 15 kV and 25 kV applications.
What type of product is this?
This product is an enhanced Elastimold 200 amp loadbreak elbow.
What type of product is this?
This product is an enhanced Elastimold 200 amp loadbreak elbow.
What standards and certifications does it meet?
The product is IEEE 386 compliant, has ANSI certification, and Rural Utilities Service (RUS) acceptance.
What certifications does this product have?
It has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What are the voltage ratings for this product?
The loadbreak elbow is available for 15 kV and 25 kV applications.
What are the voltage ratings for this product?
The loadbreak elbow is available for 15 kV and 25 kV applications.
What certifications does this product have?
It has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
How to Install the 162LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for preparing the cable, assembling the 162LR Loadbreak Elbow Connector, and connecting it to a de-energized bushing.
Estimated time: 1h 30m
Tools needed:
Wire brush, Crimp tool, Probe wrench, Hotstick tool, Wire strippers or utility knife, Vinyl tape (if applicable)
Supplies needed:
162LR Loadbreak Elbow Connector (housing, probe, lubricant), Compression Lug, Lubricant (supplied with connector), UD Cable (appropriate type), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral/ground), Cold shrink tube (if using specific sealing kits), Conductive copper tape (if using specific sealing kits)
- Perform Initial Safety Checks and Prepare Workspace
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts. This product must be installed only by competent personnel trained in high voltage electrical safety. Inspect all package contents to ensure they are complete and undamaged. Verify all components are compatible with your cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; if resistance is encountered before full assembly, check for damage and replace the component. Gather all required tools and maintain a clean work area throughout the procedure.
- Prepare the Cable End
Train the cable to provide sufficient slack for future operation. Based on your specific cable type (e.g., non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the cable end by removing the outer jacket, unwrapping/binding neutral or drain wires, or removing the copper tape shield to the specified lengths as per the cable cut-back diagram. Cut the cable squarely at the bushing centerline. Remove the insulation shield and insulation 2-1/8” (55mm) from the cable end, ensuring a square cut without nicking the conductor. Remove the insulation shield 6-7/8” (175mm) from the cable end. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Install the Compression Lug
Wire brush the bare aluminum conductors immediately after exposure. Install the compression lug onto the prepared conductor, rotating it to evenly spread the inhibitor. Position the compression lug so its contact threaded hole aligns precisely with the bushing bore. Crimp the lug using the recommended crimp tool, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.
- Assemble the Elbow Connector Housing
Apply the supplied lubricant to the cable insulation and the inside of the elbow housing. DO NOT SUBSTITUTE other lubricants. Keep the insulation clean. Slide the elbow connector onto the cable using a back-and-forth twisting motion until fully seated. Wipe off any excess lubricant. Align the elbow connector with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends, indicating proper torque.
- Connect Grounding and Neutrals
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the ground and neutral wires to allow for elbow operation. If using a cold shrink grounding kit, follow the instructions provided with that kit.
- Connect the Elbow to the Bushing
DANGER: Re-confirm that both the transformer and the elbow are DE-ENERGIZED before attempting to connect. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick tool to the loadbreak connector pulling eye. Using the hotstick, insert the elbow connector onto the bushing with a fast, firm, and straight motion, applying sufficient force to engage the internal lock. DO NOT ATTEMPT TO OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.